All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire guards must have a current
answer

Certificate of Fitness
question

The Certificate of Fitness holder
answer

must regulate the pressure and flow of oxygen and natural gas to each torch.
question

if the torch operator for jewelry manufacture involves
answer

any oxygen with any fuel gas containers, the operator must be a C of F holder.
question

A Certificate of Fitness Holder must keep his or her certificate
answer

on their person or otherwise readily available for inspection by any representative of the fire Department
question

The easiest way to extinguish a fire caused by a leak is to
answer

close the shutoff valve
question

Permits issued by the FDNY are required to conduct the following hot work:
answer

storing, using or handling oxygen and a flammable gas, storing, using or handling any flammable gas (e.g. LPG or CNG or acetylene) in excess of 400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in excess of 504 SCF.
question

For LPG, 400 SCF is
answer

approximately 47 lbs
question

the number of LPG containers for the storage, use, handling or transportation, requiring a permit
answer

14.1 oz = 54 cont. 16.4 oz = 46 cont. 20 lbs = 3 cont. 33.5 lbs = 2 cont. 40 lbs = 2 cont. 100 lbs = 1 cont.
question

Portable LPG containers that are more than 16.4 oz and CNG containers with a capacity greater than 8.7 SCF
answer

must NOT stored, handled, or used indoors in the following occupancies (as defined in the Building code): residential occupancies, factory and industrial occupancies; educational occupancies; institutional occupancies, except as the commissioner may authorize by rule.
question

Site-specific permit
answer

may be a permanent permit or a temporary permit. Permanent permits are valid for 12 months only
question

A city-wide permit is valid
answer

up to 30 days
question

Permits shall be
answer

readily available on the premise for inspection by Fire Department representatives.
question

Hot work authorization should be issued by the responsible person, and it
answer

must be available for inspection by any representative of the department during the performance of the work, and for 48 hours after the work is complete
question

FDNY permits
answer

will be posted in a central location and recorded in a log book to assist in the coordination of construction related activities.
question

CNG
answer

Compressed Natural Gas.
question

For Citywide hot work operations, the Owner of the premises must be notified in writing at least _____ hours in advance prior to work beginning.
answer

48
question

A class A fire extinguisher fights fires from
answer

Paper
question

How old must a candidate be in order to earn a Certificate of Fitness?
answer

18 Years Old
question

What type of fire is a Class B fire extinguisher used on?
answer

Oil
question

Examples of combustibles include
answer

Newspaper
question

An example of a flammable material would be
answer

Gasoline
question

Fire extinguishers must be inspected once every
answer

Month
question

A work area should be
answer

Well Ventilated
question

A type C fire involves
answer

Live electrical equipment
question

Automatic sprinkler heads should be
answer

covered by a damp cloth and removed after hot work
question

A permit is required for storing a flammable gas in excess of
answer

400 scf
question

Acetylene burns at
answer

3000 degrees Fahrenheit
question

It is dangerous to use fuel gas at pressures above
answer

15 psi
question

A fire extinguisher must be mounted
answer

so that the top is not more than 5 feet off the floor
question

To extinguish a fire
answer

Always approach the fire from upwind
question

PASS stands for
answer

Pull, Aim, Squeeze, Sweep
question

In the case of any fire,
answer

The FDNY must be notified
question

For piped gas,
answer

the gas should be shut off first
question

Oxygen cylinders are made of
answer

Steel
question

A temporary permit to conduct torch operations is valid from
answer

1 day to 12 months
question

A hot work permit is required for
answer

welding
question

A spark producing tool
answer

requires a Fire Guard
question

Soldering and brazing temperatures are typically
answer

840 degrees Fahrenheit
question

Oxy-Acetylene can generate a temperature of up to
answer

6000 degrees Fahrenheit
question

An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a
answer

Hot Work Area
question

A person holding a Certificate of Fitness who is trained and responsible for maintaining a fire watch is known as a
answer

Fire Guard
question

Most fires are the result of
answer

sparks
question

What should you do if ice buildup occurs on the gas cylinder itself?
answer

call 911 immediately
question

If a Certificate of Fitness holder discovers that an oxygen regulator is defective, they should
answer

take it out of service
question

If a gas container is unmarked, the certificate of fitness holder should
answer

take the cylinder out of service
question

What tank condition would be cause to remove it from service?
answer

the pressure relief valve shows visible damage
question

A control valve should be
answer

opened by hand
question

Persons conducting Torch Operations must possess a current
answer

G-60 Certificate of Fitness
question

A rapid, persistent chemical reaction that releases heat and light, especially the burning of a combustible substance in the presence of oxygen.
answer

A Fire
question

A class B fire extinguisher fights fires from
answer

oil
question

A written statement issued by the commissioner certifying that the person to whom it is issued has passed an examination as to his or her qualifications or is otherwise deemed qualified to use or supervise the storage, handling and use of a material
answer

Certificate of Fitness
question

What type of fire is a Class A fire extinguisher used on?
answer

cardboard
question

An example of a flammable material would be
answer

kerosene
question

Fire extinguishers must be maintained by a W-96 Certificate of Fitness holder every
answer

year
question

A type D fire involves
answer

Combustible Metals
question

A type of clothing that should not be worn when performing torch operations is
answer

Frayed Clothing.
question

A flame going out unexpectedly and creating a popping sound is known as
answer

Backfire.
question

When a cutting or welding flame burns inside a torch is known as
answer

Flashback.
question

To check for a leak one should
answer

Use a soap and water solution.
question

A fire extinguisher must be mounted
answer

so that the top is not more than 5 feet off the floor
question

A work area should be
answer

Well ventilated.
question

To extinguish a fire
answer

Always approach the fire from upwind.
question

How should a gas cylinder be stored?
answer

Upright and not on shelves.
question

In the case of any fire,
answer

The FDNY must be notified.
question

Acetylene valves should not be opened more than
answer

1 1/2 turns
question

\”SCF\” stands for
answer

Standard Cubic Feet
question

A Certificate of Fitness Holder must keep his or her certificate
answer

On their person.
question

A Citywide permit is valid for up to
answer

30 Days
question

A hot work permit is required for
answer

Welding.
question

A spark producing tool
answer

Requires a Fire Guard.
question

To prevent injury hoses should be
answer

As short as practical.
question

The oxygen cylinder
answer

is made of steel and contains 100% oxygen.
question

A compressed gas container must
answer

Not be rolled on its side.
question

An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a
answer

Hot work area.
question

Fuel gas or oxygen containers in storage must be separated from any combustible materials by a minimum distance of
answer

20 feet.
question

Most fires are the result of
answer

Sparks.
question

Sparks and pieces of hot metal are the source of ignition in about______ of fires in industrial occupancies.
answer

60.
question

Under no circumstances can hot work be performed within _____ feet of flammable or explosive materials.
answer

35.
question

If torch operation is to be discontinued for a period of ___________, the torch valve must be closed and the gas supply to the torch must be completely shut.
answer

One hour or more.
question

A torch should be ignited by using a
answer

Friction device.
question

Why should oil or grease not be used near oxygen?
answer

It might cause an explosion.
question

How long is a site permanent specific permit to store flammable gases valid for?
answer

30 days
question

How many Fire Guards are required on a job site that has 3 torches in operation?
answer

One per torch and additional one stationed on the floor below.
question

Portable LPG containers greater than ______ must not be stored in residential occupancies.
answer

16.4 oz.
question

An oxygen cylinder may store gas at pressure up to
answer

2200 psi.
question

A Responsible Person is one who is
answer

trained in the fire safety hazards associated with hot work, and in the necessary and appropriate measures to minimize those hazards, who is designated by the owner of a premises to authorize the performance of hot work at the premises.
question

A designated Hot Work area must be at least_______ feet away from combustible materials.
answer

35.
question

For all Hot Work, inspections must be completed_______ after completion of torch operations.
answer

30 minutes.
question

A minimum ___________ rating Fire Extinguisher must be readily accessible within ________ of the hot work location for torch operations.
answer

2-A:20-B:C, 30 feet.
question

For a Torch-applied Roof System, a minimum ___________ rating Fire Extinguisher must be readily accessible within ________.
answer

3-A: 40-B:C, 30 feet.
question

Empty compressed gas cylinders
answer

Should be handled in the same manner as full ones.
question

Panic Bar
answer

A device fitted on the inside of a door that would allow a person to push against a door to open it.
question

A type of valve typically used in sprinkler systems
answer

OS & Y Valve- Outside Screw and Yoke Valve.
question

Fire Drill
answer

A training exercise by which building occupants are familiarized with and/ or practice the procedures for the safe, orderly and expeditious in-building relocation, partial evacuation or evacuation, as applicable to the occupancy or building type, in accordance with the fire safety and evacuation plan.
question

shall not be considered a fire
answer

flame used in any lawful, properly operating device, equipment or system or other controlled setting.
question

Fire Watch
answer

A temporary measure intended to ensure continuous and systematic surveillance of a building or portion thereof by one or more qualified individuals for the purposes of identifying and controlling fire hazards, detecting early signs of fire, raising an alarm of fire and notifying the department.
question

Hot Work
answer

Cutting, welding, thermit welding, brazing, soldering, grinding, thermal spraying, thawing pipe, cad welding, installation of torch-applied system, or any other similar operation or activity.
question

Torch Applied Roof-System
answer

Bituminous roofing systems using membranes that are adhered by heating with a torch and melting asphalt back coating instead of mopping hot asphalt for adhesion.
question

Egress
answer

A means of exit from a fire or other emergency.
question

Single Action fire alarm pull station
answer

requires the user to simply pull a lever or break glass to activate the alarm. This type is commonly used indoors.
question

Double Action fire alarm pull station
answer

Double Action fire alarm pull station- requires the user to take two steps in order to activate the alarm such as lifting a cover and then pulling a lever. This type of alarm is commonly used outside.
question

All gas containers and the related equipment
answer

must be protected from extreme temperature and physical damage.
question

Any single standard portable LPG container must not exceed
answer

100 lbs in weight.
question

Any single CNG container must not exceed
answer

381 SCF.
question

Permits shall be readily available on the premise for inspection by
answer

Fire Department representatives.
question

NFPA stands for
answer

National Fire Protection Association.
question

Most common fuel gases used in blowtorches are
answer

LPG (e.g. butane, propane), natural gas (methane) (either CNG or piped natural gas).
question

A fire guard is responsible for
answer

overseeing torch operations.
question

The pre-hot work check must be conducted by
answer

the responsible person before hot work is authorized and at least once per day.
question

The check reports must be kept at the work site
answer

maintained on the premises for a minimum of 48 hours after work is complete.
question

Exhaust fans
answer

may be used to draw the fumes away from the work area
question

The workers should
answer

wear flame resistant gloves and aprons and should not be worm Clothing with pockets or cuffs