FDNYC G60 Practice Exam
Unlock all answers in this set
Unlock answersquestion
All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire guards must have a current
answer
Certificate of Fitness
question
The Certificate of Fitness holder
answer
must regulate the pressure and flow of oxygen and natural gas to each torch.
question
if the torch operator for jewelry manufacture involves
answer
any oxygen with any fuel gas containers, the operator must be a C of F holder.
question
A Certificate of Fitness Holder must keep his or her certificate
answer
on their person or otherwise readily available for inspection by any representative of the fire Department
question
The easiest way to extinguish a fire caused by a leak is to
answer
close the shutoff valve
question
Permits issued by the FDNY are required to conduct the following hot work:
answer
storing, using or handling oxygen and a flammable gas, storing, using or handling any flammable gas (e.g. LPG or CNG or acetylene) in excess of 400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in excess of 504 SCF.
question
For LPG, 400 SCF is
answer
approximately 47 lbs
question
the number of LPG containers for the storage, use, handling or transportation, requiring a permit
answer
14.1 oz = 54 cont. 16.4 oz = 46 cont. 20 lbs = 3 cont. 33.5 lbs = 2 cont. 40 lbs = 2 cont. 100 lbs = 1 cont.
question
Portable LPG containers that are more than 16.4 oz and CNG containers with a capacity greater than 8.7 SCF
answer
must NOT stored, handled, or used indoors in the following occupancies (as defined in the Building code): residential occupancies, factory and industrial occupancies; educational occupancies; institutional occupancies, except as the commissioner may authorize by rule.
question
Site-specific permit
answer
may be a permanent permit or a temporary permit. Permanent permits are valid for 12 months only
question
A city-wide permit is valid
answer
up to 30 days
question
Permits shall be
answer
readily available on the premise for inspection by Fire Department representatives.
question
Hot work authorization should be issued by the responsible person, and it
answer
must be available for inspection by any representative of the department during the performance of the work, and for 48 hours after the work is complete
question
FDNY permits
answer
will be posted in a central location and recorded in a log book to assist in the coordination of construction related activities.
question
CNG
answer
Compressed Natural Gas.
question
For Citywide hot work operations, the Owner of the premises must be notified in writing at least _____ hours in advance prior to work beginning.
answer
48
question
A class A fire extinguisher fights fires from
answer
Paper
question
How old must a candidate be in order to earn a Certificate of Fitness?
answer
18 Years Old
question
What type of fire is a Class B fire extinguisher used on?
answer
Oil
question
Examples of combustibles include
answer
Newspaper
question
An example of a flammable material would be
answer
Gasoline
question
Fire extinguishers must be inspected once every
answer
Month
question
A work area should be
answer
Well Ventilated
question
A type C fire involves
answer
Live electrical equipment
question
Automatic sprinkler heads should be
answer
covered by a damp cloth and removed after hot work
question
A permit is required for storing a flammable gas in excess of
answer
400 scf
question
Acetylene burns at
answer
3000 degrees Fahrenheit
question
It is dangerous to use fuel gas at pressures above
answer
15 psi
question
A fire extinguisher must be mounted
answer
so that the top is not more than 5 feet off the floor
question
To extinguish a fire
answer
Always approach the fire from upwind
question
PASS stands for
answer
Pull, Aim, Squeeze, Sweep
question
In the case of any fire,
answer
The FDNY must be notified
question
For piped gas,
answer
the gas should be shut off first
question
Oxygen cylinders are made of
answer
Steel
question
A temporary permit to conduct torch operations is valid from
answer
1 day to 12 months
question
A hot work permit is required for
answer
welding
question
A spark producing tool
answer
requires a Fire Guard
question
Soldering and brazing temperatures are typically
answer
840 degrees Fahrenheit
question
Oxy-Acetylene can generate a temperature of up to
answer
6000 degrees Fahrenheit
question
An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a
answer
Hot Work Area
question
A person holding a Certificate of Fitness who is trained and responsible for maintaining a fire watch is known as a
answer
Fire Guard
question
Most fires are the result of
answer
sparks
question
What should you do if ice buildup occurs on the gas cylinder itself?
answer
call 911 immediately
question
If a Certificate of Fitness holder discovers that an oxygen regulator is defective, they should
answer
take it out of service
question
If a gas container is unmarked, the certificate of fitness holder should
answer
take the cylinder out of service
question
What tank condition would be cause to remove it from service?
answer
the pressure relief valve shows visible damage
question
A control valve should be
answer
opened by hand
question
Persons conducting Torch Operations must possess a current
answer
G-60 Certificate of Fitness
question
A rapid, persistent chemical reaction that releases heat and light, especially the burning of a combustible substance in the presence of oxygen.
answer
A Fire
question
A class B fire extinguisher fights fires from
answer
oil
question
A written statement issued by the commissioner certifying that the person to whom it is issued has passed an examination as to his or her qualifications or is otherwise deemed qualified to use or supervise the storage, handling and use of a material
answer
Certificate of Fitness
question
What type of fire is a Class A fire extinguisher used on?
answer
cardboard
question
An example of a flammable material would be
answer
kerosene
question
Fire extinguishers must be maintained by a W-96 Certificate of Fitness holder every
answer
year
question
A type D fire involves
answer
Combustible Metals
question
A type of clothing that should not be worn when performing torch operations is
answer
Frayed Clothing.
question
A flame going out unexpectedly and creating a popping sound is known as
answer
Backfire.
question
When a cutting or welding flame burns inside a torch is known as
answer
Flashback.
question
To check for a leak one should
answer
Use a soap and water solution.
question
A fire extinguisher must be mounted
answer
so that the top is not more than 5 feet off the floor
question
A work area should be
answer
Well ventilated.
question
To extinguish a fire
answer
Always approach the fire from upwind.
question
How should a gas cylinder be stored?
answer
Upright and not on shelves.
question
In the case of any fire,
answer
The FDNY must be notified.
question
Acetylene valves should not be opened more than
answer
1 1/2 turns
question
"SCF" stands for
answer
Standard Cubic Feet
question
A Certificate of Fitness Holder must keep his or her certificate
answer
On their person.
question
A Citywide permit is valid for up to
answer
30 Days
question
A hot work permit is required for
answer
Welding.
question
A spark producing tool
answer
Requires a Fire Guard.
question
To prevent injury hoses should be
answer
As short as practical.
question
The oxygen cylinder
answer
is made of steel and contains 100% oxygen.
question
A compressed gas container must
answer
Not be rolled on its side.
question
An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a
answer
Hot work area.
question
Fuel gas or oxygen containers in storage must be separated from any combustible materials by a minimum distance of
answer
20 feet.
question
Most fires are the result of
answer
Sparks.
question
Sparks and pieces of hot metal are the source of ignition in about______ of fires in industrial occupancies.
answer
60.
question
Under no circumstances can hot work be performed within _____ feet of flammable or explosive materials.
answer
35.
question
If torch operation is to be discontinued for a period of ___________, the torch valve must be closed and the gas supply to the torch must be completely shut.
answer
One hour or more.
question
A torch should be ignited by using a
answer
Friction device.
question
Why should oil or grease not be used near oxygen?
answer
It might cause an explosion.
question
How long is a site permanent specific permit to store flammable gases valid for?
answer
30 days
question
How many Fire Guards are required on a job site that has 3 torches in operation?
answer
One per torch and additional one stationed on the floor below.
question
Portable LPG containers greater than ______ must not be stored in residential occupancies.
answer
16.4 oz.
question
An oxygen cylinder may store gas at pressure up to
answer
2200 psi.
question
A Responsible Person is one who is
answer
trained in the fire safety hazards associated with hot work, and in the necessary and appropriate measures to minimize those hazards, who is designated by the owner of a premises to authorize the performance of hot work at the premises.
question
A designated Hot Work area must be at least_______ feet away from combustible materials.
answer
35.
question
For all Hot Work, inspections must be completed_______ after completion of torch operations.
answer
30 minutes.
question
A minimum ___________ rating Fire Extinguisher must be readily accessible within ________ of the hot work location for torch operations.
answer
2-A:20-B:C, 30 feet.
question
For a Torch-applied Roof System, a minimum ___________ rating Fire Extinguisher must be readily accessible within ________.
answer
3-A: 40-B:C, 30 feet.
question
Empty compressed gas cylinders
answer
Should be handled in the same manner as full ones.
question
Panic Bar
answer
A device fitted on the inside of a door that would allow a person to push against a door to open it.
question
A type of valve typically used in sprinkler systems
answer
OS & Y Valve- Outside Screw and Yoke Valve.
question
Fire Drill
answer
A training exercise by which building occupants are familiarized with and/ or practice the procedures for the safe, orderly and expeditious in-building relocation, partial evacuation or evacuation, as applicable to the occupancy or building type, in accordance with the fire safety and evacuation plan.
question
shall not be considered a fire
answer
flame used in any lawful, properly operating device, equipment or system or other controlled setting.
question
Fire Watch
answer
A temporary measure intended to ensure continuous and systematic surveillance of a building or portion thereof by one or more qualified individuals for the purposes of identifying and controlling fire hazards, detecting early signs of fire, raising an alarm of fire and notifying the department.
question
Hot Work
answer
Cutting, welding, thermit welding, brazing, soldering, grinding, thermal spraying, thawing pipe, cad welding, installation of torch-applied system, or any other similar operation or activity.
question
Torch Applied Roof-System
answer
Bituminous roofing systems using membranes that are adhered by heating with a torch and melting asphalt back coating instead of mopping hot asphalt for adhesion.
question
Egress
answer
A means of exit from a fire or other emergency.
question
Single Action fire alarm pull station
answer
requires the user to simply pull a lever or break glass to activate the alarm. This type is commonly used indoors.
question
Double Action fire alarm pull station
answer
Double Action fire alarm pull station- requires the user to take two steps in order to activate the alarm such as lifting a cover and then pulling a lever. This type of alarm is commonly used outside.
question
All gas containers and the related equipment
answer
must be protected from extreme temperature and physical damage.
question
Any single standard portable LPG container must not exceed
answer
100 lbs in weight.
question
Any single CNG container must not exceed
answer
381 SCF.
question
Permits shall be readily available on the premise for inspection by
answer
Fire Department representatives.
question
NFPA stands for
answer
National Fire Protection Association.
question
Most common fuel gases used in blowtorches are
answer
LPG (e.g. butane, propane), natural gas (methane) (either CNG or piped natural gas).
question
A fire guard is responsible for
answer
overseeing torch operations.
question
The pre-hot work check must be conducted by
answer
the responsible person before hot work is authorized and at least once per day.
question
The check reports must be kept at the work site
answer
maintained on the premises for a minimum of 48 hours after work is complete.
question
Exhaust fans
answer
may be used to draw the fumes away from the work area
question
The workers should
answer
wear flame resistant gloves and aprons and should not be worm Clothing with pockets or cuffs