Chrysene C18H12 structure – Flashcards

Flashcard maker : Marguerite Castillo

Molecular Formula C18H12
Average mass 228.288 Da
Density 1.2±0.1 g/cm3
Boiling Point 448.0±0.0 °C at 760 mmHg
Flash Point 209.1±13.7 °C
Molar Refractivity 79.8±0.3 cm3
Polarizability 31.6±0.5 10-24cm3
Surface Tension 53.5±3.0 dyne/cm
Molar Volume 191.8±3.0 cm3
  • Experimental data
  • Predicted – ACD/Labs
  • Predicted – EPISuite
  • Predicted – ChemAxon
  • Predicted – Mcule
  • Experimental Physico-chemical Properties
    • Experimental Melting Point:

      255 °C TCI C0339
      253 °C Oxford University Chemical Safety Data (No longer updated) More details
      252-256 °C Merck Millipore 4766, 841690
      253 °C Jean-Claude Bradley Open Melting Point Dataset 15668
      254 °C Jean-Claude Bradley Open Melting Point Dataset 17279
      258.2 °C Jean-Claude Bradley Open Melting Point Dataset 20061
      258 °C Jean-Claude Bradley Open Melting Point Dataset 27929, 27930, 27931, 27932
      255 °C Jean-Claude Bradley Open Melting Point Dataset 27929, 27930, 27931, 27932
      252 °C Biosynth W-201895
      250-255 °C LabNetwork LN01277834
    • Experimental Boiling Point:

      448 °C Oxford University Chemical Safety Data (No longer updated) More details
      448 °C Biosynth W-201895
    • Experimental Flash Point:

      209.14 °C Biosynth W-201895
    • Experimental Gravity:

      209.14 g/mL Biosynth W-201895
    • Experimental Solubility:

      -8.06 Egon Willighagen http://dx.doi.org/10.1021/ci050282s
  • Predicted Physico-chemical Properties
    • Predicted Melting Point:

      255 °C TCI
      255 °C TCI C0339
  • Miscellaneous
    • Appearance:

      crystalline powder Oxford University Chemical Safety Data (No longer updated) More details
    • Stability:

      Stable. Combustible. Incompatible with strong oxidizing agents. Oxford University Chemical Safety Data (No longer updated) More details
    • Toxicity:

      IPR-MUS LD50 >320 mg kg-1 Oxford University Chemical Safety Data (No longer updated) More details
    • Safety:

      Danger Biosynth W-201895
      GHS08; GHS09 Biosynth W-201895
      H341; H350; H410 Biosynth W-201895
      P201; P273; P281; P308+P313; P501 Biosynth W-201895
      Safety glasses, good ventilation, gloves. Handle as a carcinogen.A COSHH assessment is required. Oxford University Chemical Safety Data (No longer updated) More details
      T,N Abblis Chemicals AB1006861
      Toxic SynQuest 1600-1-12
  • Gas Chromatography
    • Retention Index (Kovats):

      2210 (estimated with error: 174) NIST Spectra mainlib_149624, replib_122226
      2406 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Start T: 240 C; CAS no: 218019; Active phase: CP Sil 5 CB; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Hanai, T.; Hong, C., Structure-retention correlation in CGC, J. Hi. Res. Chromatogr., 12, 1989, 327-332.) NIST Spectra nist ri
      2429 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.21 mm; Column length: 17.5 m; Column type: Capillary; Start T: 240 C; CAS no: 218019; Active phase: SE-30; Carrier gas: He; Data type: Kovats RI; Authors: Pozhidaev, V.M.; Berezkin, V.G.; Korolev, A.A.; Popova, T.P.; Pozhidaeva, K.A., Retention indices of polycyclic aromatic hydrocarbons on quartz capillary columns with chemically immobilized stationary phases, Zh. Anal. Khim., 43, 1988, 1082-1088.) NIST Spectra nist ri
      2438 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.21 mm; Column length: 17.5 m; Column type: Capillary; Start T: 240 C; CAS no: 218019; Active phase: SE-30; Carrier gas: He; Data type: Kovats RI; Authors: Pozhidaev, V.M.; Berezkin, V.G.; Korolev, A.A.; Popova, T.P.; Pozhidaeva, K.A., Retention indices of polycyclic aromatic hydrocarbons on quartz capillary columns with chemically immobilized stationary phases, Zh. Anal. Khim., 43, 1988, 1082-1088.) NIST Spectra nist ri
      2439 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.21 mm; Column length: 17.5 m; Column type: Capillary; Start T: 240 C; CAS no: 218019; Active phase: SE-30; Carrier gas: He; Data type: Kovats RI; Authors: Pozhidaev, V.M.; Berezkin, V.G.; Korolev, A.A.; Popova, T.P.; Pozhidaeva, K.A., Retention indices of polycyclic aromatic hydrocarbons on quartz capillary columns with chemically immobilized stationary phases, Zh. Anal. Khim., 43, 1988, 1082-1088.) NIST Spectra nist ri
      2447 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.21 mm; Column length: 17.5 m; Column type: Capillary; Start T: 240 C; CAS no: 218019; Active phase: SE-30; Carrier gas: He; Data type: Kovats RI; Authors: Pozhidaev, V.M.; Berezkin, V.G.; Korolev, A.A.; Popova, T.P.; Pozhidaeva, K.A., Retention indices of polycyclic aromatic hydrocarbons on quartz capillary columns with chemically immobilized stationary phases, Zh. Anal. Khim., 43, 1988, 1082-1088.) NIST Spectra nist ri
      2480 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.21 mm; Column length: 17.5 m; Column type: Capillary; Start T: 260 C; CAS no: 218019; Active phase: SE-30; Carrier gas: He; Data type: Kovats RI; Authors: Pozhidaev, V.M.; Berezkin, V.G.; Korolev, A.A.; Popova, T.P.; Pozhidaeva, K.A., Retention indices of polycyclic aromatic hydrocarbons on quartz capillary columns with chemically immobilized stationary phases, Zh. Anal. Khim., 43, 1988, 1082-1088.) NIST Spectra nist ri
      2486 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.21 mm; Column length: 17.5 m; Column type: Capillary; Start T: 260 C; CAS no: 218019; Active phase: SE-30; Carrier gas: He; Data type: Kovats RI; Authors: Pozhidaev, V.M.; Berezkin, V.G.; Korolev, A.A.; Popova, T.P.; Pozhidaeva, K.A., Retention indices of polycyclic aromatic hydrocarbons on quartz capillary columns with chemically immobilized stationary phases, Zh. Anal. Khim., 43, 1988, 1082-1088.) NIST Spectra nist ri
      2488 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.21 mm; Column length: 17.5 m; Column type: Capillary; Start T: 260 C; CAS no: 218019; Active phase: SE-30; Carrier gas: He; Data type: Kovats RI; Authors: Pozhidaev, V.M.; Berezkin, V.G.; Korolev, A.A.; Popova, T.P.; Pozhidaeva, K.A., Retention indices of polycyclic aromatic hydrocarbons on quartz capillary columns with chemically immobilized stationary phases, Zh. Anal. Khim., 43, 1988, 1082-1088.) NIST Spectra nist ri
      2491 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.21 mm; Column length: 17.5 m; Column type: Capillary; Start T: 260 C; CAS no: 218019; Active phase: SE-30; Carrier gas: He; Data type: Kovats RI; Authors: Pozhidaev, V.M.; Berezkin, V.G.; Korolev, A.A.; Popova, T.P.; Pozhidaeva, K.A., Retention indices of polycyclic aromatic hydrocarbons on quartz capillary columns with chemically immobilized stationary phases, Zh. Anal. Khim., 43, 1988, 1082-1088.) NIST Spectra nist ri
      2408 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.33 mm; Column length: 25 m; Column type: Capillary; Start T: 220 C; CAS no: 218019; Active phase: SE-30; Carrier gas: N2; Data type: Kovats RI; Authors: Korhonen, I.O.O.; Lind, M.A., Gas-liquid chromatographic analyses. XXXIV. Separation and retention indices with retention increments of some nitrated polynuclear aromatic hydrocarbons on a low-polarity (SE-30) capillary column, J. Chromatogr., 322, 1985, 71-81.) NIST Spectra nist ri
      2456 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.33 mm; Column length: 25 m; Column type: Capillary; Start T: 240 C; CAS no: 218019; Active phase: SE-30; Carrier gas: N2; Data type: Kovats RI; Authors: Korhonen, I.O.O.; Lind, M.A., Gas-liquid chromatographic analyses. XXXIV. Separation and retention indices with retention increments of some nitrated polynuclear aromatic hydrocarbons on a low-polarity (SE-30) capillary column, J. Chromatogr., 322, 1985, 71-81.) NIST Spectra nist ri
      2489 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 3 m; Column type: Packed; Start T: 250 C; CAS no: 218019; Active phase: OV-101; Carrier gas: N2; Data type: Kovats RI; Authors: Rudenko, B.A.; Bulychova, Z.Yu.; Topunov, V.N.; Itsikson, L.B., Regularities in changes of retention indices for polycyclic aromatic hydrocarbons depending on their structure and polarity of stationary phase, Zh. Anal. Khim., 39(4), 1984, 700-706.) NIST Spectra nist ri
      2490 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.50 mm; Column length: 50 m; Column type: Capillary; Start T: 270 C; CAS no: 218019; Active phase: OV-101; Carrier gas: N2; Data type: Kovats RI; Authors: Grimmer, G.; Bohnke, H., Bestimmung des Gesamtgehaltes aller polycyclischen aromatischen Kohlenwasserstoffe in Luftstaub und Kraftfahrzeugabgas mit der Capillar-Gas-Chromatographie, Z. Anal. Chem., 261, 1972, 310-314.) NIST Spectra nist ri
      2461.9 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.21 mm; Column length: 17.5 m; Column type: Capillary; Start T: 240 C; CAS no: 218019; Active phase: SE-52; Carrier gas: He; Data type: Kovats RI; Authors: Pozhidaev, V.M.; Berezkin, V.G.; Korolev, A.A.; Popova, T.P.; Pozhidaeva, K.A., Retention indices of polycyclic aromatic hydrocarbons on quartz capillary columns with chemically immobilized stationary phases, Zh. Anal. Khim., 43, 1988, 1082-1088.) NIST Spectra nist ri
    • Retention Index (Lee):

      400 (Column class: All column type… (show more) s; CAS no: 218019; Data type: Lee RI value specified by scale definition; Authors: Lee, M.L.; Vassilaros, D.L.; White, C.M.; Novotny, M., Retention Indices for Programmed-Temperature Capillary-Column Gas Chromatography of Polycyclic Aromatic Hydrocarbons, Anal. Chem., 51(6), 1979, 768-773.) NIST Spectra nist ri
    • Retention Index (Normal Alkane):

      2411 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.25 mm; Column length: 25 m; Column type: Capillary; Description: 50 0C (2 min) ^ 20 0C/min -> 160 0C ^ 5 0C/min -> 210 0C ^ 10 0C/min -> 300 0C; CAS no: 218019; Active phase: Methyl Silicone; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Oda, J.; Yasuhara, A.; Matsunaga, K.; Saito, Y., Identification of polycyclic aromatic hydrocarbons of the particulate accumulated in the tunnel duct of freeway and generation of their oxygenated derivatives, Jpn. J. Toxicol. Environ. Health, 44(5), 1998, 334-351.) NIST Spectra nist ri
      2428 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.2 mm; Column length: 50 m; Column type: Capillary; Heat rate: 3 K/min; Start T: 60 C; End T: 300 C; End time: 35 min; CAS no: 218019; Active phase: Ultra-1; Carrier gas: H2; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Elizalde-Gonzalez, M.P.; Hutfliess, M.; Hedden, K., Retention index system, adsorption characteristics, and sructure correlations of polycyclic aromatic hydrocarbons in fuels, J. Hi. Res. Chromatogr., 19, 1996, 345-352.) NIST Spectra nist ri
      2401.7 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.2 mm; Column length: 12 m; Column type: Capillary; Heat rate: 18 K/min; Start T: 60 C; End T: 265 C; Start time: 1 min; CAS no: 218019; Active phase: HP-1; Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Liao, W.; Joe, T.; Cusick, W.G., Multiresidue screening method for fresh fruits and vegetables with gas chromatographic/mass spectrometric detection, J. Ass. Offic. Anal. Chem, 74(3), 1991, 554-565.) NIST Spectra nist ri
      2406.1 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 1.1 m; Column type: Packed; Heat rate: 8.5 K/min; Start T: 50 C; End T: 300 C; CAS no: 218019; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W HP; Data type: Normal alkane RI; Authors: Saxton, W.L., Emergence temperature indices and relative retention times of pesticides and industrial chemicals determined by linear programmed temperature gas chromatography, J. Chromatogr., 393, 1987, 175-194.) NIST Spectra nist ri
      2444.8 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.5 mm; Column length: 100 m; Column type: Capillary; CAS no: 218019; Active phase: OV-101; Carrier gas: N2; Data type: Normal alkane RI; Authors: Grimmer. G.; Bohnke, H.; Glaser, A., Polyscyclische aromatische Kohlen-wasserstoffe im Abgas von Kraftfahrzeugen, Erdol und Kohle., 30(9), 1977, 411-417.) NIST Spectra nist ri
      2461.9 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Packed; CAS no: 218019; Active phase: SE-30; Substrate: Chromosorb W; Data type: Normal alkane RI; Authors: Wilmshurst, J.R., Gas-chromatographic analysis of polynuclear arenes, J. Chromatogr., 17, 1965, 50-59.) NIST Spectra nist ri
      2447.9 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 50 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 280 C; End time: 30 min; CAS no: 218019; Active phase: HP-5MS; Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Wang, S.-F.; Liu, B.-Z.; Sun, K.-J.; Su, Q.-D., Gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons formed during the pyrolysis of phenylalanine, J. Chromatogr. A, 1025, 2004, 255-261.) NIST Spectra nist ri
      2450 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 310 C; Start time: 2 min; CAS no: 218019; Active phase: HP-5; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Miao, X.; Wu, F., Study on retention behaviors of polycyclic aromatic hydrocarbons by gas chromatography in different operation models, J. Instrumental Anal., 15(4), 1999, 288-292.) NIST Spectra nist ri
      2451 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 310 C; Start time: 2 min; CAS no: 218019; Active phase: HP-5; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Miao, X.; Wu, F., Study on retention behaviors of polycyclic aromatic hydrocarbons by gas chromatography in different operation models, J. Instrumental Anal., 15(4), 1999, 288-292.) NIST Spectra nist ri
      2457 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 310 C; Start time: 2 min; CAS no: 218019; Active phase: HP-5; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Miao, X.; Wu, F., Study on retention behaviors of polycyclic aromatic hydrocarbons by gas chromatography in different operation models, J. Instrumental Anal., 15(4), 1999, 288-292.) NIST Spectra nist ri
      2458 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 310 C; Start time: 2 min; CAS no: 218019; Active phase: HP-5; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Miao, X.; Wu, F., Study on retention behaviors of polycyclic aromatic hydrocarbons by gas chromatography in different operation models, J. Instrumental Anal., 15(4), 1999, 288-292.) NIST Spectra nist ri
      2462 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 310 C; Start time: 2 min; CAS no: 218019; Active phase: HP-5; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Miao, X.; Wu, F., Study on retention behaviors of polycyclic aromatic hydrocarbons by gas chromatography in different operation models, J. Instrumental Anal., 15(4), 1999, 288-292.) NIST Spectra nist ri
      2463 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 310 C; Start time: 2 min; CAS no: 218019; Active phase: HP-5; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Miao, X.; Wu, F., Study on retention behaviors of polycyclic aromatic hydrocarbons by gas chromatography in different operation models, J. Instrumental Anal., 15(4), 1999, 288-292.) NIST Spectra nist ri
      2491 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 310 C; Start time: 2 min; CAS no: 218019; Active phase: HP-5; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Miao, X.; Wu, F., Study on retention behaviors of polycyclic aromatic hydrocarbons by gas chromatography in different operation models, J. Instrumental Anal., 15(4), 1999, 288-292.) NIST Spectra nist ri
      2492 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 310 C; Start time: 2 min; CAS no: 218019; Active phase: HP-5; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Miao, X.; Wu, F., Study on retention behaviors of polycyclic aromatic hydrocarbons by gas chromatography in different operation models, J. Instrumental Anal., 15(4), 1999, 288-292.) NIST Spectra nist ri
      2437.1 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 90C (1min) => 10C/min => 120C => 4C/min => 310C (20min); CAS no: 218019; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Zamperlini, G.C.M.; Silva, M.R.S.; Vilegas, W., Identification of polycyclic aromatic hydrocarbons in sugar cane soot by gas chromatography-mass spectrometry, Chromatographia, 46(11/12), 1997, 655-663.) NIST Spectra nist ri
      2453 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 60 C; End T: 290 C; CAS no: 218019; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.1 um; Data type: Normal alkane RI; Authors: Quilliam, M.A.; Lant, M.S.; Kaiser-Farrell, C.; McCalla, D.R.; Sheldrake, C.P.; Kerr, A.A.; Lockington, J.N.; Gibson, E.S., Identification of polycyclic aromatic compounds in of poly-mutagenic emissions from steel casting, Biomed. Mass Spectrom., 12(4), 1985, 143-150.) NIST Spectra nist ri
      2456 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 60 C; End T: 290 C; CAS no: 218019; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.1 um; Data type: Normal alkane RI; Authors: Quilliam, M.A.; Lant, M.S.; Kaiser-Farrell, C.; McCalla, D.R.; Sheldrake, C.P.; Kerr, A.A.; Lockington, J.N.; Gibson, E.S., Identification of polycyclic aromatic compounds in of poly-mutagenic emissions from steel casting, Biomed. Mass Spectrom., 12(4), 1985, 143-150.) NIST Spectra nist ri
    • Retention Index (Linear):

      2409.82 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 60C=>7C/min=>225C=>15C/min=>300C(11.43min); CAS no: 218019; Active phase: HP-1; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Dimitriou-Christidis, P.; Harris, B.C.; McDonald, T.J.; Reese, E.; Autenrieth, R.L., Estimation of selected physicochemical properties for methylated naphthalene compounds, Chemosphere, 52, 2003, 869-881.) NIST Spectra nist ri
      2474.4 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.2 mm; Column length: 25 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 100 C; End T: 180 C; CAS no: 218019; Active phase: OV-1; Phase thickness: 0.33 um; Data type: Linear RI; Authors: Zhang, M.-J.; Shen, S.-D.; Chen, S.-Y.; Sun, Y.-H., Analysis of heavy oil fractions in high-temperature coal tar by capillary gas chromatography/fourier transform infrared spectrometry, Chin. J. Chromatogr., 18(3), 2000, 241-246.) NIST Spectra nist ri
      2442.66 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Heat rate: 15 K/min; Start T: 35 C; End T: 320 C; End time: 10 min; CAS no: 218019; Active phase: Ultra-1; Phase thickness: 0.52 um; Data type: Linear RI; Authors: Richmond, R.; Pombo-Villar, E., Short communication. Gas chromatography-mass spectrometry coupled with pseudo-Sadtler retention indices, for the identification of components in the essential oil of Curcuma longa L., J. Chromatogr. A, 760, 1997, 303-308.) NIST Spectra nist ri
      2443 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Description: 50C(2min)=>(20C/min)=>120C=>(7C/min)=>310C(10min); CAS no: 218019; Active phase: OV-101; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Yasuhara, A.; Shiraishi, H.; Nishikawa, M.; Yamamoto, T.; Uehiro, T.; Nakasugi, O.; Okumura, T.; Kenmotsu, K.; Fukui, H.; Nagase, M.; Ono, Y.; Kawagoshi, Y.; Baba, K.; Noma, Y., Determination of organic components in leachates from hazardous waste disposal sites in Japan by gas chromatography-mass spectrometry, J. Chromatogr. A, 774, 1997, 321-332.) NIST Spectra nist ri
      2442.5 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Capillary; Heat rate: 8 K/min; Start T: 35 C; End T: 300 C; CAS no: 218019; Active phase: OV-1; Data type: Linear RI; Authors: Gautzsch, R.; Zinn, P., Use of incremental models to estimate the retention indexes of aromatic compounds, Chromatographia, 43(3/4), 1996, 163-176.) NIST Spectra nist ri
      2401 (Program type: Complex; Column… (show more) class: Standard non-polar; Column type: Capillary; Description: 50C (2min) =>20C/min =>160C => 5C/min =>210C => 10C/min =>300C; CAS no: 218019; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Oda, J.; Ichikawa, S.; Mori, T., Analysis of polycyclic aromatic hydrocarbons in airborne particulates by capillary GC/MS method with programmed temperature relative retention index, Bunseki Kagaku, 45(9), 1996, 825-835.) NIST Spectra nist ri
      2463.1 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.21 mm; Column length: 17.5 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 100 C; End T: 280 C; CAS no: 218019; Active phase: SE-30; Carrier gas: He; Data type: Linear RI; Authors: Pozhidaev, V.M.; Berezkin, V.G.; Korolev, A.A.; Popova, T.P.; Pozhidaeva, K.A., Retention indices of polycyclic aromatic hydrocarbons on quartz capillary columns with chemically immobilized stationary phases, Zh. Anal. Khim., 43, 1988, 1082-1088.) NIST Spectra nist ri
      2454 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.33 mm; Column length: 25 m; Column type: Capillary; Heat rate: 6 K/min; Start T: 140 C; End T: 320 C; CAS no: 218019; Active phase: SE-30; Carrier gas: N2; Data type: Linear RI; Authors: Korhonen, I.O.O.; Lind, M.A., Gas-liquid chromatographic analyses. XXXIV. Separation and retention indices with retention increments of some nitrated polynuclear aromatic hydrocarbons on a low-polarity (SE-30) capillary column, J. Chromatogr., 322, 1985, 71-81.) NIST Spectra nist ri
      2465 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.33 mm; Column length: 25 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 100 C; End T: 320 C; CAS no: 218019; Active phase: SE-30; Carrier gas: N2; Data type: Linear RI; Authors: Korhonen, I.O.O.; Lind, M.A., Gas-liquid chromatographic analyses. XXXIV. Separation and retention indices with retention increments of some nitrated polynuclear aromatic hydrocarbons on a low-polarity (SE-30) capillary column, J. Chromatogr., 322, 1985, 71-81.) NIST Spectra nist ri
      2471.68 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 60C=>7C/min=>225C=>15C/min=>300C(11.43min); CAS no: 218019; Active phase: HP-5; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Dimitriou-Christidis, P.; Harris, B.C.; McDonald, T.J.; Reese, E.; Autenrieth, R.L., Estimation of selected physicochemical properties for methylated naphthalene compounds, Chemosphere, 52, 2003, 869-881.) NIST Spectra nist ri
      2434.2 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 40 C; End T: 310 C; CAS no: 218019; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Lai, W.-C.; Song, C., Temperature-programmed retention indices for g.c. and g.c.-m.s. analysis of coal- and petroleum-derived liquid fuels, Fuel, 74(10), 1995, 1436-1451., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 40 C; End T: 310 C; CAS no: 218019; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Song, C.; Lai, W.-C.; Madhusudan Reddy, K.; Wei, B., Chapter 7. Temperature-programmed retention indices for GC and GC-MS of hydrocarbon fuels and simulated distillation GC of heavy oils, in Analytical advances for hydrocarbon research, Hsu,C.S., ed(s), Kluwer Academic/Plenum Publishers, New York, 2003, 147-193.) NIST Spectra nist ri
      2471.8 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 40 C; End T: 310 C; Start time: 5 min; CAS no: 218019; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Lai, W.-C.; Song, C., Temperature-programmed retention indices for g.c. and g.c.-m.s. analysis of coal- and petroleum-derived liquid fuels, Fuel, 74(10), 1995, 1436-1451., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 40 C; End T: 310 C; Start time: 5 min; CAS no: 218019; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Song, C.; Lai, W.-C.; Madhusudan Reddy, K.; Wei, B., Chapter 7. Temperature-programmed retention indices for GC and GC-MS of hydrocarbon fuels and simulated distillation GC of heavy oils, in Analytical advances for hydrocarbon research, Hsu,C.S., ed(s), Kluwer Academic/Plenum Publishers, New York, 2003, 147-193.) NIST Spectra nist ri
      2472.3 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 40 C; End T: 310 C; CAS no: 218019; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Lai, W.-C.; Song, C., Temperature-programmed retention indices for g.c. and g.c.-m.s. analysis of coal- and petroleum-derived liquid fuels, Fuel, 74(10), 1995, 1436-1451., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 40 C; End T: 310 C; CAS no: 218019; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Song, C.; Lai, W.-C.; Madhusudan Reddy, K.; Wei, B., Chapter 7. Temperature-programmed retention indices for GC and GC-MS of hydrocarbon fuels and simulated distillation GC of heavy oils, in Analytical advances for hydrocarbon research, Hsu,C.S., ed(s), Kluwer Academic/Plenum Publishers, New York, 2003, 147-193.) NIST Spectra nist ri
      2494.9 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 6 K/min; Start T: 40 C; End T: 310 C; CAS no: 218019; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Lai, W.-C.; Song, C., Temperature-programmed retention indices for g.c. and g.c.-m.s. analysis of coal- and petroleum-derived liquid fuels, Fuel, 74(10), 1995, 1436-1451., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 6 K/min; Start T: 40 C; End T: 310 C; CAS no: 218019; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Song, C.; Lai, W.-C.; Madhusudan Reddy, K.; Wei, B., Chapt

      Get an explanation on any task
      Get unstuck with the help of our AI assistant in seconds
      New