Molecular Formula | C11H18N2O3 |
Average mass | 226.272 Da |
Density | 1.2±0.1 g/cm3 |
Boiling Point | |
Flash Point | |
Molar Refractivity | 59.3±0.5 cm3 |
Polarizability | 23.5±0.5 10-24cm3 |
Surface Tension | 42.6±7.0 dyne/cm |
Molar Volume | 185.2±7.0 cm3 |
- Experimental data
- Predicted – ACD/Labs
- Predicted – EPISuite
- Predicted – ChemAxon
- Experimental Physico-chemical Properties
-
Experimental Melting Point:
157 °C Jean-Claude Bradley Open Melting Point Dataset 17102, 22182, 27780 156 °C Jean-Claude Bradley Open Melting Point Dataset 13076, 8926
-
- Gas Chromatography
-
Retention Index (Kovats):
1785 (estimated with error: 89) NIST Spectra mainlib_250567, replib_42301, replib_232502, replib_312628, replib_335573 1710 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; Start T: 200 C; CAS no: 57432; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G AW DMCS (80-100 mesh); Data type: Kovats RI; Authors: Moller, M.R., Comparability of retention indices of polar substances at elevated temperatures, Chromatographia, 9(7), 1976, 311-314., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 30 K/min; Start T: 100 C; End T: 310 C; End time: 5 min; Start time: 3 min; CAS no: 57432; Active phase: SE-30; Carrier gas: N2; Data type: Kovats RI; Authors: Maurer, H.H., Identification and differentiation of barbiturates, other sedative-hypnotics and their metabolites in urine integrated in a general screening procedure using computerized gas chromatography-mass spectrometry, J. Chromatogr., 530, 1990, 307-326.) NIST Spectra nist ri 1694 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Start T: 200 C; CAS no: 57432; Active phase: DB-1; Carrier gas: N2; Phase thickness: 1.5 um; Data type: Kovats RI; Authors: Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 32(6), 1987, 1574-1586.) NIST Spectra nist ri 1695 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.22 mm; Column length: 25 m; Column type: Capillary; Start T: 200 C; CAS no: 57432; Active phase: BP-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 32(6), 1987, 1574-1586.) NIST Spectra nist ri 1705 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.53 mm; Column length: 25 m; Column type: Capillary; Start T: 200 C; CAS no: 57432; Active phase: BP-1; Carrier gas: N2; Phase thickness: 1 um; Data type: Kovats RI; Authors: Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 32(6), 1987, 1574-1586.) NIST Spectra nist ri 1727 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.20 mm; Column length: 25 m; Column type: Capillary; Start T: 250 C; CAS no: 57432; Active phase: SPB-1; Carrier gas: He; Data type: Kovats RI; Authors: Lora-Tamayo, C.; Rams, M.A.; Chacon, J.M.R., Gas Chromatographic Data for 187 Nitrogen- or Phosphorus-Containing Drugs and Metabolites of Toxicological Interest Analysed on Methyl Silicone Capillary Columns, J. Chromatogr., 374, 1986, 73-85.) NIST Spectra nist ri 1696 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.49 mm; Column length: 25 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 100 C; End T: 275 C; End time: 15 min; Start time: 2 min; CAS no: 57432; Active phase: SE-30; Phase thickness: 1.14 um; Data type: Kovats RI; Authors: Schepers, P.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A., Applicability of capillary gas chromatography to substance identification in toxicology by means of retention indices, J. Forensic Sci., 27(1), 1982, 49-60.) NIST Spectra nist ri 1698 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 300 C; End time: 12 min; Start time: 2 min; CAS no: 57432; Active phase: SE-30; Carrier gas: He; Phase thickness: 0.45 um; Data type: Kovats RI; Authors: Schepers, P.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A., Applicability of capillary gas chromatography to substance identification in toxicology by means of retention indices, J. Forensic Sci., 27(1), 1982, 49-60.) NIST Spectra nist ri 1700 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Packed; Start T: 200 C; CAS no: 57432; Active phase: SE-30; Data type: Kovats RI; Authors: Stead, A.H.; Gill, R.; Evans, A.T.; Moffat, A.C., Predictions of gas chromatographic retention characteristics of barbiturates from molecular structure, J. Chromatogr., 234, 1982, 277-283.) NIST Spectra nist ri 1760 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; CAS no: 57432; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W; Data type: Kovats RI; Authors: McLinden, V.J.; Stenhouse, A.M., A chromatography system for drug identification, Forensic Sci. Int., 13, 1979, 71-79.) NIST Spectra nist ri 1702 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; Start T: 200 C; CAS no: 57432; Active phase: OV-1; Substrate: Chromosorb G; Data type: Kovats RI; Authors: Dubsky, H.; Hana, K.; Komarkova, M.; Rittich, B., Pouziti kovatsovych indexu pri toxikologickych analysach, Chem. Listy, 72, 1978, 980-984.) NIST Spectra nist ri 1714 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; Start T: 180 C; CAS no: 57432; Active phase: OV-1; Substrate: Chromosorb G; Data type: Kovats RI; Authors: Dubsky, H.; Hana, K.; Komarkova, M.; Rittich, B., Pouziti kovatsovych indexu pri toxikologickych analysach, Chem. Listy, 72, 1978, 980-984.) NIST Spectra nist ri 1715 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; Start T: 200 C; CAS no: 57432; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G AW DMCS (80-100 mesh); Data type: Kovats RI; Authors: Moller, M.R., Comparability of retention indices of polar substances at elevated temperatures, Chromatographia, 9(7), 1976, 311-314., Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Packed; Start T: 200 C; CAS no: 57432; Active phase: OV-1; Data type: Kovats RI; Authors: Berninger, H.; Moller, M.R., Retentionsindices zur gaschromatographischen Identifizierung von Arzneimitteln, Arch. Toxicol., 37, 1977, 295-305.) NIST Spectra nist ri 1735 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Start T: 220 C; CAS no: 57432; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.2 um; Data type: Kovats RI; Authors: Phillips, A.M.; Logan, B.K.; Stafford, D.T., Further applications for capillary gas chromatography in routine quantitative toxicological analyses, J. Hi. Res. Chromatogr., 13, 1990, 754-758.) NIST Spectra nist ri -
Retention Index (Normal Alkane):
1695 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; CAS no: 57432; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Capillary; Start T: 100 C; End T: 300 C; CAS no: 57432; Active phase: BP-1; Data type: Normal alkane RI; Authors: MHA, Directorate of ForensicScience., Forensic Toxicology, 9999.) NIST Spectra nist ri 1723.5 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.75 mm; Column length: 30 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 155 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 57432; Active phase: SPB-1; Carrier gas: He; Phase thickness: 10 um; Data type: Normal alkane RI; Authors: Coudore, F.; Alazard, J.-M.; Paire, M.; Andraud, G.; Lavarenne, J., Rapid toxicological screening of barbiturates in plasma by wide-bore capillary gas chromatography and nitrogen-phosphorus detection, J. Anal. Toxicol., 17, 1993, 109-113.) NIST Spectra nist ri 1717.5 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.26 mm; Column length: 30 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 22 min; Start time: 1 min; CAS no: 57432; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Manca, D.; Ferron, L.; Weber, J-P., A System for Toxicological Screening by Capillary Gas Chromatography with Use of Drug Retention Index Based on Nitrogen-Containing Reference Compounds, Clin. Chem., 35(4), 1989, 601-607.) NIST Spectra nist ri 1718 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.26 mm; Column length: 30 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 22 min; Start time: 1 min; CAS no: 57432; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Manca, D.; Ferron, L.; Weber, J-P., A System for Toxicological Screening by Capillary Gas Chromatography with Use of Drug Retention Index Based on Nitrogen-Containing Reference Compounds, Clin. Chem., 35(4), 1989, 601-607., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 57432; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W AW DMS; Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can.Soc.Forens.Sci.J., 9(2), 1975, 69-74., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 57432; Active phase: SE-30; Carrier gas: Nitrogen; Substrate: Chromosorb W AW DMS (80-100 mesh); Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can. Soc. Forens. Sci. J., 9(2), 1976, 69-74., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Other; CAS no: 57432; Active phase: Methyl Silicone; Data type: Normal alkane RI; Authors: Ardrey, R.E.; Moffat, A.C., Gas-liquid chromatographic retention indices of 1318 substances of toxicological interest on SE-30 or OV-1 stationary phase, J. Chromatogr., 220, 1981, 195-252.) NIST Spectra nist ri 1685 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column length: 10 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 130 C; End T: 230 C; CAS no: 57432; Active phase: DB-1; Carrier gas: He; Phase thickness: 2.65 um; Data type: Normal alkane RI; Authors: Anderson, W.H.; Fuller, D.C., A simplified procedure for the isolation, characterization, and identification of weak acid and neutral drugs from whole blood, J. Anal. Toxicol., 11, 1987, 198-204.) NIST Spectra nist ri 1692 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Description: 120 0X ^ 8 0C/min -> 270 0C ^ 25 0C/min -> 300 0C (5 min); CAS no: 57432; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 130 C; End T: 290 C; End time: 10 min; Start time: 1 min; CAS no: 57432; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Sharp, M.E., A rapid screening procedure for acidic and neutral drugs in blood by high resolution gas chromatography, J. Anal. Toxicol., 11, 1987, 8-11.) NIST Spectra nist ri 1689 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Description: 120 0X ^ 8 0C/min -> 270 0C ^ 25 0C/min -> 300 0C (5 min); CAS no: 57432; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri 1690 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 50 C; End T: 300 C; CAS no: 57432; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri 1691 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; CAS no: 57432; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri 1697 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Description: 120 0X ^ 8 0C/min -> 270 0C ^ 25 0C/min -> 300 0C (5 min); CAS no: 57432; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; CAS no: 57432; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 57432; Active phase: SE-30; Carrier gas: Nitrogen; Substrate: Chromosorb W AW DMS (80-100 mesh); Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can. Soc. Forens. Sci. J., 9(2), 1976, 69-74.) NIST Spectra nist ri 1703 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; CAS no: 57432; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri 1725 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; Start T: 200 C; CAS no: 57432; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G AW DMCS (80-100 mesh); Data type: Normal alkane RI; Authors: Moller, M.R., Comparability of retention indices of polar substances at elevated temperatures, Chromatographia, 9(7), 1976, 311-314., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; CAS no: 57432; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri 1750 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; Heat rate: 2.5 K/min; Start T: 120 C; End T: 200 C; CAS no: 57432; Active phase: SE-30; Substrate: Gas Chrom P; Data type: Normal alkane RI; Authors: Marozzi, E.; Gambaro, V.; Saligari, E.; Mariani, R.; Lodi, F., Use of the retention index in gas chromatographic studies of drugs, J. Anal. Toxicol., 6, 1982, 185-192.) NIST Spectra nist ri 1722.8 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; Heat rate: 10 K/min; Start T: 220 C; End T: 270 C; CAS no: 57432; Active phase: OV-101; Substrate: Chromosorb (100-120 mesh); Data type: Normal alkane RI; Authors: Cailleux, A.; Turcant, A.; Premel-Cabic, A.; Allain, P., Identification and Quantitation of Neutral and Basic Drugs in Blood By Gas Chromatography and Mass Spectrometry, J. Chromatogr. Sci., 19, 1981, 163-176.) NIST Spectra nist ri 1710 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 1.5 m; Column type: Packed; CAS no: 57432; Active phase: Apolane; Data type: Normal alkane RI; Authors: Huggett, A.; Andrews, P.; Flanagan, R.J., Rapid Micro-Method for the Measurement of Paracetamol in Blood Plasma or Serum Using Gas-Liquid Chromatography with Flame-Ionisation Detection., J. Chromatogr., 209, 1981, 67-76., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 57432; Active phase: SE-30; Carrier gas: Nitrogen; Substrate: Chromosorb W AW DMS (80-100 mesh); Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can. Soc. Forens. Sci. J., 9(2), 1976, 69-74.) NIST Spectra nist ri 1711 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 57432; Active phase: SE-30; Carrier gas: Nitrogen; Substrate: Chromosorb W AW DMS (80-100 mesh); Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can. Soc. Forens. Sci. J., 9(2), 1976, 69-74.) NIST Spectra nist ri 1712 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 57432; Active phase: SE-30; Carrier gas: Nitrogen; Substrate: Chromosorb W AW DMS (80-100 mesh); Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can. Soc. Forens. Sci. J., 9(2), 1976, 69-74.) NIST Spectra nist ri 1713 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 57432; Active phase: SE-30; Carrier gas: Nitrogen; Substrate: Chromosorb W AW DMS (80-100 mesh); Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can. Soc. Forens. Sci. J., 9(2), 1976, 69-74.) NIST Spectra nist ri 1721 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 57432; Active phase: SE-30; Carrier gas: Nitrogen; Substrate: Chromosorb W AW DMS (80-100 mesh); Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can. Soc. Forens. Sci. J., 9(2), 1976, 69-74.) NIST Spectra nist ri 1731.8 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 50 C; End T: 320 C; Start time: 1 min; CAS no: 57432; Active phase: HP-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Tienpont, B.; David, F.; Stopforth, A.; Sandra, P., Comprehensive Profiling of Drugs of Abuse in Biological Fluids by Stir-Bar Sorptive Extraction-Thermal Desorption-Capillary Gas Chromatography-Mass Spectrometry, LCGC Europe, , 2003, 2-10.) NIST Spectra nist ri 1739 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 15 m; Column type: Capillary; Heat rate: 15 K/min; Start T: 90 C; End T: 320 C; CAS no: 57432; Active phase: DB-5; Carrier gas: He; Phase thickness: 1.5 um; Data type: Normal alkane RI; Authors: Takeda, A.; Tanaka, H.; Shinohara, T.; Ohtake, I., Systematic analysis of acid, neutral and basic drugs in horse plasma by combination of solid-phase extraction, non-aqueous partitioning and gas chromatography-mass spectrometry, J. Chromatogr. B, 758, 2001, 235-248.) NIST Spectra nist ri 1684.2 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.34 mm; Column length: 18 m; Column type: Capillary; Heat rate: 25 K/min; Start T: 100 C; End T: 275 C; End time: 5 min; Start time: 2 min; CAS no: 57432; Active phase: CP Sil 8 CB; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: de Baere, S.M.; Lambert, W.E.; van Bocxlaer, J.F.; de Leenheer, A.P., Quantitative gas chromatographic analysis of 3-cyano-3,3-diphenylpropionic acid, the acidic metabolite of bezitramide (Burgodin), in urine, J. Anal. Toxicol., 20, 1996, 159-164.) NIST Spectra nist ri 1731.9 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Description: 70 0C (0.7 min) ^ 20 0C/min -> 140 0C ^ 10 0C/min -> 280 0C (4 min); CAS no: 57432; Active phase: NB-54; Carrier gas: He; Phase thickness: 0.10 um; Data type: Normal alkane RI; Authors: Ojanpera, I.; Rasanen, I.; Vuori, E., Automated quantitative screening for acidic and neutral drugs in whole blood by dual-column capillary gas chromatography, J. Anal. Toxicol., 15, 1991, 204-208.) NIST Spectra nist ri 1710.7 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 12.5 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 110 C; End T: 290 C; End time: 6.5 min; Start time: 1 min; CAS no: 57432; Active phase: Ultra-2; Phase thickness: 0.5 um; Data type: Normal alkane RI; Authors: Watts, V.W.; Simonick, T.F., A retention index library for commonly encountered drugs and metabolites using tri-n-alkylamines as reference compounds, nitrogen-phosphorus detectors, and dual capillary chromatography, J. Anal. Toxicol., 11, 1987, 210-214.) NIST Spectra nist ri -
Retention Index (Linear):
1711 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.53 mm; Column length: 10 m; Column type: Capillary; Description: 100 0C (2 min ) ^ 15 0C/min -> 200 0C ^ 10 0C/min -> 300 0C (8 min hold); CAS no: 57432; Active phase: CP Sil 5 CB; Carrier gas: He; Phase thickness: 5.0 um; Data type: Linear RI; Authors: Aderjan, R.; Bogusz, M., Nitroalkanes as a multidetector retention index scale for drug identification in gas chromatography, J. Chromatogr., 454, 1988, 345-351.) NIST Spectra nist ri 1718 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.75 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 160 C; End T: 280 C; End time: 12 min; CAS no: 57432; Active phase: SPB-1; Carrier gas: He; Phase thickness: 1.0 um; Data type: Linear RI; Authors: Christ, D.W.; Noomano, P.; Rosas, M.; Rhone, D., Retention indices by wide-bore capillary gas chromatography with nitrogen-phosphorus detection, J. Anal. Toxicol., 12, 1988, 84-88.) NIST Spectra nist ri 1682 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column length: 12 m; Column type: Capillary; Heat rate: 6 K/min; Start T: 120 C; End T: 250 C; CAS no: 57432; Active phase: CBP-1; Carrier gas: N2; Data type: Linear RI; Authors: Oyama, N.; Sano, T.; Syoyama, M.; Maeda, K., Studies on systematic analysis of poisonous compounds in forensic chemistry. II. Application of capillary column gas chromatography to substance identification by means of retention indices, Eisei Kagaku, 33(5), 1987, 342-348.) NIST Spectra nist ri 1697 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Description: 120C=>8C/min=>270C=>25C/min=>300C; CAS no: 57432; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Stowell, A.; Wilson, L.W., A simple approach to the interlaboratory transfer of drug retention indices determined by temperature programmed capillary gas chromatography, J. Forensic Sci., 32(5), 1987, 1214-1220., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 5 min; CAS no: 57432; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Perrigo, B.J.; Ballantyne, D.J.; Peel, H.W., Condierations in developing a data base for drugs on a DBI capillary column, J. Can. Soc. Forensic Sci., 17(2), 1984, 41-49., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 15 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 5 min; CAS no: 57432; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Perrigo, B.J.; Peel, H.W.; Ballantyne, D.J., Use of Dual-Column Fused-Silica Capillary Gas Chromatography in Combination with Detector Response Factors for Analytical Toxicology., J. Chromatogr., 341, 1985, 81-88.) NIST Spectra nist ri 1690 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.2 mm; Column length: 12 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 50 C; End T: 300 C; End time: 3 min; Start time: 1 min; CAS no: 57432; Active phase: Methyl Silicone; Carrier gas: He; Phase thickness: 0.33 um; Data type: Linear RI; Authors: Newton, B.; Foery, R.F., Retention indices and dual capillary gas chromatography for rapid identification of sedative hypnotic drugs in emergency toxicology, J. Anal. Toxicol., 8, 1984, 129-134.) NIST Spectra nist ri 1720 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 1.8 m; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 57432; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W; Data type: Linear RI; Authors: Perrigo, B.J.; Peel, H.W., The use of retention indices and temperature-programmed gas chromatography in analytical toxicology, J. Chromatogr. Sci., 19, 1981, 219-226.) NIST Spectra nist ri 1737 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 12 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 50 C; End T: 300 C; End time: 3 min; Start time: 1 min; CAS no: 57432; Active phase: 5 % Phenyl methyl siloxane; Carrier gas: He; Phase thickness: 0.33 um; Data type: Linear RI; Authors: Newton, B.; Foery, R.F., Retention indices and dual capillary gas chromatography for rapid identification of sedative hypnotic drugs in emergency toxicology, J. Anal. Toxicol., 8, 1984, 129-134.) NIST Spectra nist ri
-
Predicted data is generated using the ACD/Labs Percepta Platform – PhysChem Module
Density: | 1.2±0.1 g/cm3 |
Boiling Point: | |
Vapour Pressure: | |
Enthalpy of Vaporization: | |
Flash Point: | |
Index of Refraction: | 1.554 |
Molar Refractivity: | 59.3±0.5 cm3 |
#H bond acceptors: | 5 |
#H bond donors: | 2 |
#Freely Rotating Bonds: | 4 |
#Rule of 5 Violations: | 0 |
ACD/LogP: | 1.78 |
ACD/LogD (pH 5.5): | 1.03 |
ACD/BCF (pH 5.5): | 3.03 |
ACD/KOC (pH 5.5): | 63.55 |
ACD/LogD (pH 7.4): | -0.56 |
ACD/BCF (pH 7.4): | 1.00 |
ACD/KOC (pH 7.4): | 1.66 |
Polar Surface Area: | 79 Å2 |
Polarizability: | 23.5±0.5 10-24cm3 |
Surface Tension: | 42.6±7.0 dyne/cm |
Molar Volume: | 185.2±7.0 cm3 |