question
A typical color used for the fourth conductor of a power cable is ______. a. pink b. yellow c. red d. blue
answer
blue
question
Type _______ cable is flat conductor cable. a. E b. MV c. FCC d. CC
answer
FCC
question
Type ____ cable is nonmetallic-sheathed cable. a. SE b. SIS c. NMS d. NMSC
answer
NMS
question
Type______ cable is power and control tray cable. a. THW b. THWN c. TW d. TC
answer
TW
question
The standard system of wire sizes in the United States is the ________. a. American Wire Gauge b. Birmingham Gauge c. Manufacturers' Foundation d. Manufacturers' Standard Gauge
answer
American Wire Gauge
question
In the standard system of wire sizes in the United States, from No. 50 through No. 1, the larger the number, the __________. a. heavier the wire b. longer the wire c. smaller the wire d. larger the wire
answer
smaller the wire
question
Copper is the most widely used conductor because it __________. a. offers the lowest resistance b. is lightweight and inexpensive c. is easy to use d. offers low resistance and is easy to use
answer
offers low resistance and is easy to use
question
The grounding wire may be _______. a. red b. white ç. black d. bare
answer
bare
question
Cable markings show ________. a. suitable locations b. voltage rating c. definitions of color codes d. ampacity
answer
voltage rating
question
The purpose of stranding is to_____. a. reduce weight b. increase wìre flexibility c. add strength d. make the wire easier to insulate
answer
increase wìre flexibility
question
When conductors are led into long runs of conduit, it is important to_____. a. put back-tension on the conductors to prevent kinking b. fill the conduit with lubricant c. hold tension on the spools so that excess wire does not spill onto the floor d. make sure the wires are straight and do not cross over each other
answer
make sure the wires are straight and do not cross over each other
question
Instrumentation wiring shielding is usually ________. a. grounded at every instrument b. grounded at one end only c. not grounded at all d. grounded by floating the ground at both ends of the wire
answer
grounded at one end only
question
The selection of fixture wire depends primarily on the _________. a. type of circuit control b. type of termination c. circuit color coding d. operating temperature of the circuit
answer
operating temperature of the circuit
question
Type SE cable may be used ________ . a. underground b. above ground and underground c. underground in non-hazrdous locations d. above ground only
answer
above ground only
question
Type MC cable may be used _________. a. where subject to physical damage b. as direct burial cable c. in concrete d. for services, feeders, and branch circuits
answer
for services, feeders, and branch circuits
question
A factor not used in selecting conductors is tne conductor's _________. a. termination point b. site (diameter) c. length d. operating temperature
answer
length
question
Type UF cable may be used _________. a. as a service entrance cable b. in commercial garages c. underground and in direct burial situations d. in hazardous locations
answer
underground and in direct burial situations
question
NM and NMU cables may be ______. a. used in ducts and plenums b. installed exposed in the space above suspended ceilings c. used as service entrance cable d. installed in concealed locations
answer
installed in concealed locations
question
What is the primary difference between NM and NMC cable? a. NM is for dry environments only; NMC is for both dry and damp locations. b. NM Is for exposed locations; NMC is for concealed locations. c. They are rated differently for the number of conductors allowed. d. NM cable is fire-retardant, while NMC is not.
answer
NM is for dry environments only; NMC is for both dry and damp locations.
question
Which size wire has the greatest cross-sectional area? a. 0 b. 00 c. 000 d. 0000
answer
0000
question
A conductor's size refers to the cross-sectional area of both the current-carrying wire and the insulation. a. True b. False
answer
True
question
The maximum size solid wire that should be terminated in pull boxes and disconnects is______. a. No.6 b. No. 8 c. No. 10 d. No.12
answer
No. 8
question
Compact stranding is used _____. a. when installing larger conduit sizes b. when decreasing the ampacity of an existing service c. with aluminum conductors d. in corrosive environments
answer
with aluminum conductors
question
The ampacity ratings of conductors can be found in,__. a. NEC Chapter l b. NEC Articles 348 through 352 c. NEC Tables 310.16 through 310.19 d. NEC Chapter 9
answer
NEC Tables 310.16 through 310.19
question
To determine the ampacity of copper conductors where conductors are used as a single conductor in free air at ambient temperatures of 3OC, use: a. NEC Table 310.16 b. NEC Table 310.17 c. NEC Table 310.18 d. NEC Table 310.19
answer
NEC Table 310.16
question
All of the Following help to determine how good a material will be for the construction of wire except a. availability b. cost c. conductivity d. molecular weight
answer
molecular weight
question
A type of thermoset insulation ¡s a. RHW b. THW c. THHW d. PVC
answer
RHW
question
Polyethylene (PE) is used primarily for a. the manufacture of TW and THW insulation b. insulation of control and communication wiring c. high-voltage cables d. high-temperature insulation
answer
insulation of control and communication wiring
question
What letter must be included in the marking of a conductor if it is to be used in a wet, outdoor application? a. D b. O c. I d. W
answer
W
question
What service conductor may be bare, green, or green with a yellow stripe? a. The grounding conductor of a multi-conductor cable b. The neutral conductor of a multi-conductor cable c. The ungrounded conductor of a multi-conductor cable d. The high leg of a four-wire, delta-connected secondary
answer
The grounding conductor of a multi-conductor cable
question
What are the colors of insulation on the conductors for a three-conductor NM cable? a. One white or gray, one red, and one black b. Two white or gray and one red c. One white or gray, one red, one black, and a grounding conductor d. One green, one white or gray, one blue and a grounding conductor
answer
One white or gray, one red, one black, and a grounding conductor
question
A conductor's operating temperature is not determined by a. ambient temperature b. current flow c. current flow in bundled conductors d. the number of conductor strands
answer
the number of conductor strands
question
In some cases, fixture wires may be used as a substitute for branch circuit conductors. a. True b. False
answer
False
question
Type NMC cable is suitable for all of the following except a. dry locations b. damp locations c. corrosive locations d. embedding in concrete
answer
embedding in concrete
question
The difference between AC cable and MC cable is____. a. AC cable has a maximum of four conductors; MC has a maximum of six b. AC cable has a bonding strip; the MC ground is its metal cladding c. AC cable has fire-retardant wraps on individual conductors; MC cable does not d. AC cable is sized from 10 AWG to 4/O; MC issized from 18AWG to 2,000kcmil
answer
AC cable has fire-retardant wraps on individual conductors; MC cable does not
question
Type USF cable can be used for a. aboveground installation only b. underground installation within a special PVC pipeline c. underground installation including direct burial d. indoor applications only
answer
underground installation including direct burial
question
To prevent unwanted ground loops, instrument wiring is___ a. not grounded at both ends of the wire b. grounded at both ends of the wire c. floated on both ends d. always ungrounded
answer
not grounded at both ends of the wire
question
A pulling line is usually made of: a. stranded wire b. wire rope c. steel tape d. nylon or other synthetic material
answer
nylon or other synthetic material
question
When feeding conductors into long runs of conduit, it is important to apply lubricant to the conductors only, and not to the conduit. a. True b. False
answer
False
question
The NEC specifies a minimum of for connections made to wiring devices or for splices. a. 4" b. 6" c. 8" d. lO"
answer
6"