Anthracene C14H10 structure – Flashcards

Flashcard maker : Stephanie Landry

Molecular Formula C14H10
Average mass 178.229 Da
Density 1.1±0.1 g/cm3
Boiling Point 337.4±9.0 °C at 760 mmHg
Flash Point 146.6±12.8 °C
Molar Refractivity 61.9±0.3 cm3
Polarizability 24.6±0.5 10-24cm3
Surface Tension 48.0±3.0 dyne/cm
Molar Volume 157.7±3.0 cm3
  • Experimental data
  • Predicted – ACD/Labs
  • Predicted – EPISuite
  • Predicted – ChemAxon
  • Predicted – Mcule
  • Experimental Physico-chemical Properties
    • Experimental Melting Point:

      217 °C TCI A0992
      218 °C TCI A0495
      214-218 °C Alfa Aesar
      210-215 °C Alfa Aesar
      213-216 °C Alfa Aesar
      213-216 °C Merck Millipore 3276, 820109
      218 °C Jean-Claude Bradley Open Melting Point Dataset 17103
      215 °C Jean-Claude Bradley Open Melting Point Dataset 20256
      216.3 °C Jean-Claude Bradley Open Melting Point Dataset 27787, 27788, 27789, 27790
      216 °C Jean-Claude Bradley Open Melting Point Dataset 14263, 27787, 27788, 27789, 27790, 6392
      214-218 °C Alfa Aesar A10203
      213-216 °C Alfa Aesar A17261
      210-215 °C Alfa Aesar 32320
      214-216 °C SynQuest 72433, 1600-1-01
      210 °C Biosynth J-200085
      215 °C FooDB FDB006967
    • Experimental Boiling Point:

      340-342 °C Alfa Aesar
      340-342 °C Alfa Aesar A10203, A17261, 32320
      340 °C SynQuest 72433, 1600-1-01
      337.4 °C Biosynth J-200085
    • Experimental Vapor Pressure:

      1 mmHg SynQuest
      1 °C SynQuest 72433
      1 mmHg SynQuest 72433, 1600-1-01
    • Experimental LogP:

      4.68 Vitas-M STK398386
      4.45 Egon Willighagen http://dx.doi.org/10.1021/ci050282s
    • Experimental Flash Point:

      121 °C Alfa Aesar
      121 °C Alfa Aesar
      121 °C Biosynth J-200085
      121 °F (49.4444 °C)
      Alfa Aesar A10203, A17261, 32320
      121 °C SynQuest 72433, 1600-1-01
    • Experimental Gravity:

      1.25 g/mL Alfa Aesar A10203, A17261, 32320
      121 g/mL Biosynth J-200085
  • Predicted Physico-chemical Properties
    • Predicted Melting Point:

      215-218 °C J&K Scientific 458606
      217 °C TCI
      218 °C TCI
      217 °C TCI A0992
      218 °C TCI A0495
  • Miscellaneous
    • Safety:

      24-37-60-61 Alfa Aesar 32320, A10203, A17261
      43-50/53 Alfa Aesar 32320, A10203, A17261
      9 Alfa Aesar 32320, A10203, A17261
      DANGER: Cancer risk, reproductive hazard, skin, eye irritant Alfa Aesar 32320, A10203
      GHS07; GHS09 Biosynth J-200085
      H315; H319; H335; H410 Biosynth J-200085
      H400-H410-H317 Alfa Aesar 32320, A10203, A17261
      IRRITANT Alfa Aesar A17261
      Irritant/Environmental SynQuest 1600-1-01, 72433
      P261; P273; P305+P351+P338; P501 Biosynth J-200085
      P261-P280-P273-P363-P321-P501a Alfa Aesar 32320, A10203, A17261
      R36/37/38,R43,R50/53 SynQuest 1600-1-01, 72433
      S22,S24/25,S26,S36/37/39,S45,S60,S61 SynQuest 1600-1-01, 72433
      Warning Alfa Aesar 32320, A10203, A17261
      Warning Biosynth J-200085
      WARNING: Irritates lungs, eyes, skin Alfa Aesar 32320, A10203, A17261
      Xi,N Abblis Chemicals AB1002596
  • Gas Chromatography
    • Retention Index (Kovats):

      1782 (estimated with error: 55) NIST Spectra mainlib_228201, replib_122221, replib_249641, replib_113337
      1804 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 1 m; Column type: Packed; Start T: 160 C; CAS no: 120127; Active phase: SE-30; Substrate: Chromaton N-AW; Data type: Kovats RI; Authors: Kurbatova, S.V.; Finkelstein, E.E.; Kolosova, E.A.; Kartashev, A.V.; Rashkin, S.V., Structural analogy method in studies of adamantanes, J. Struct. Chem., 45(1), 2004, 144-150.) NIST Spectra nist ri
      1739 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.2 mm; Column length: 25 m; Column type: Capillary; Start T: 150 C; CAS no: 120127; Active phase: OV-1; Carrier gas: N2; Phase thickness: 0.33 um; Data type: Kovats RI; Authors: Zhang, M.; Chen, B.; Shen, S.; Chen, S., Compositional studies of high-temperature coal tar by g.c.-FT-i.r. analysis of middle oil fractions, Fuel, 76(5), 1997, 415-423.) NIST Spectra nist ri
      1752 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.2 mm; Column length: 25 m; Column type: Capillary; Start T: 160 C; CAS no: 120127; Active phase: OV-1; Carrier gas: N2; Phase thickness: 0.33 um; Data type: Kovats RI; Authors: Zhang, M.; Chen, B.; Shen, S.; Chen, S., Compositional studies of high-temperature coal tar by g.c.-FT-i.r. analysis of middle oil fractions, Fuel, 76(5), 1997, 415-423.) NIST Spectra nist ri
      1769 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.5 mm; Column length: 100 m; Column type: Capillary; Start T: 175 C; CAS no: 120127; Active phase: SE-30; Data type: Kovats RI; Authors: Bredael, P., Retention indices of hydrocarbons on SE-30, J. Hi. Res. Chromatogr. & Chromatogr. Comm., 5, 1982, 325-328.) NIST Spectra nist ri
      1729 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.3 mm; Column length: 50 m; Column type: Capillary; Start T: 140 C; CAS no: 120127; Active phase: OV-101; Carrier gas: N2; Data type: Kovats RI; Authors: Gerasimenko, V.A.; Kirilenko, A.V.; Nabivach, V.M., Capillary gas chromatography of aromatic compounds found in coal tar fractions, J. Chromatogr., 208, 1981, 9-16.) NIST Spectra nist ri
      2728 (Program type: Isothermal; Col… (show more) umn class: Standard polar; Column diameter: 0.25 mm; Column length: 25 m; Column type: Capillary; Start T: 240 C; CAS no: 120127; Active phase: CP-Wax; Phase thickness: 0.22 um; Data type: Kovats RI; Authors: Hanai, T.; Hong, C., Structure-retention correlation in CGC, J. Hi. Res. Chromatogr., 12, 1989, 327-332.) NIST Spectra nist ri
    • Retention Index (Lee):

      301.61 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 40 C; End T: 400 C; End time: 20 min; Start time: 8 min; CAS no: 120127; Active phase: HT-5; Data type: Lee RI; Authors: Williams, P.T.; Williams, E.A., Recycling plastic waste by pyrolysis, J. Inst. Energy, 71, 1998, 81-93., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 50 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 80 C; End T: 270 C; End time: 5 min; Start time: 2 min; CAS no: 120127; Active phase: PB-1; Carrier gas: H2; Phase thickness: 0.2 um; Data type: Lee RI; Authors: Andersson, J.T.; Weis, U., Gas Chromatographic Determination of Polycyclic Aromatic Compounds with Fluorinated Analogues as Internal Standards, J. Chromatogr. A, 659, 1994, 151-161.) NIST Spectra nist ri
      301.4 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; CAS no: 120127; Active phase: DB-5; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Lundstedt, S.; Haglund, P.; Oberg, L., Degradation and formation of polycyclic aromatic compounds during bioslurry treatment of an aged gasworks soil, Environ. Toxicol. Chem., 22(7), 2003, 1413-1420., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.18 mm; Column length: 20 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 50 C; End T: 345 C; Start time: 1.5 min; CAS no: 120127; Active phase: PE-5; Phase thickness: 0.18 um; Data type: Lee RI; Authors: Jamoussi, B.; Kanzari, F.; Hassine, B.B.; Abderrabba, A., Using Bezier curves for the calculation of retention indices of polycyclic aromatic hydrocarbons in the so-called Lee’s scale in temperature-programmed gas chromatography with mass spectrometry detection, J. Chromatogr. Sci., 45, 2007, 22-27., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 60 m; Column type: Capillary; CAS no: 120127; Active phase: DB-5MS; Data type: Lee RI; Authors: Aracil, I.; Font, R.; Conesa, J.A., Semivolatile and volatile compounds from the pyrolysis and combustion of polyvinyl chloride, J. Anal. Appl. Pyrolysis, 74, 2005, 465-478., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.3 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 200 C; End time: 15 min; Start time: 5 min; CAS no: 120127; Active phase: HP-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Shao, X.; Wang, G.; Sun, Y.; Zhang, R.; Xie, K.; Liu, H., Determination and Characterization of the Pyrolysis Products of Isoprocarb by GC-MS, J. Chromatogr. Sci., 44, 2006, 141-147., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column type: Capillary; Heat rate: 8 K/min; Start T: 80 C; End T: 300 C; End time: 10 min; Start time: 2 min; CAS no: 120127; Active phase: 5 % Phenyl methyl siloxane; Data type: Lee RI; Authors: Skrbic, B.; Onjia, A., Prediction of Lee Retention Indices of Polycyclic Aromatic Hydrocarbons by Artificial Neural Networks, J. Chromatorg. A, 1108(2), 2006, 279-284., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Capillary; CAS no: 120127; Active phase: OV-101; Data type: Lee RI; Authors: Tucminen, A.; Wickstrom, K.; Pyysalo, H., Determination of Polycyclic Aromatic Compounds by GLC-Selected Ion Monitoring (SIM) Technique, J. Hi. Res. Chromatogr. ; Chromatogr. Comm., , 1986, 469-471.) NIST Spectra nist ri
      300 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Packed; Start T: 175 C; CAS no: 120127; Active phase: Methyl Silicone; Data type: Lee RI; Authors: Shlyakhov, A.F., Gas chromatography in organic geochemistry, Nedra, Moscow, 1984, 221., Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Packed; Start T: 200 C; CAS no: 120127; Active phase: Methyl Silicone; Data type: Lee RI; Authors: Shlyakhov, A.F., Gas chromatography in organic geochemistry, Nedra, Moscow, 1984, 221., Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Packed; Start T: 235 C; CAS no: 120127; Active phase: Methyl Silicone; Data type: Lee RI; Authors: Shlyakhov, A.F., Gas chromatography in organic geochemistry, Nedra, Moscow, 1984, 221., Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Packed; Start T: 300 C; CAS no: 120127; Active phase: Methyl Silicone; Data type: Lee RI; Authors: Shlyakhov, A.F., Gas chromatography in organic geochemistry, Nedra, Moscow, 1984, 221.) NIST Spectra nist ri
      300.65 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Packed; Start T: 260 C; CAS no: 120127; Active phase: Methyl Silicone; Data type: Lee RI; Authors: Shlyakhov, A.F., Gas chromatography in organic geochemistry, Nedra, Moscow, 1984, 221.) NIST Spectra nist ri
      301.5 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 40 C; End T: 300 C; Start time: 2 min; CAS no: 120127; Active phase: SPB-5; Data type: Lee RI; Authors: Knobloch, T.; Engewald, W., Identification of some polar polycyclic compounds in emissions from brown-coal-fired residential stoves, J. Hi. Res. Chromatogr., 16, 1993, 239-242., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column length: 60 m; Column type: Capillary; CAS no: 120127; Active phase: DB-5; Data type: Lee RI; Authors: Fuentes, M.J.; Font, R.; Gomez-Rico, M.F.; Martin-Gullon, I., Pyrolysis and combustion of waste lubricant oil from diesel cars: Decomposition and pollutants, J. Anal. Appl. Pyrolysis, 79, 2007, 215-226.) NIST Spectra nist ri
      318.5 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column length: 60 m; Column type: Capillary; CAS no: 120127; Active phase: DB-5; Data type: Lee RI; Authors: Fuentes, M.J.; Font, R.; Gomez-Rico, M.F.; Martin-Gullon, I., Pyrolysis and combustion of waste lubricant oil from diesel cars: Decomposition and pollutants, J. Anal. Appl. Pyrolysis, 79, 2007, 215-226.) NIST Spectra nist ri
      319.5 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column length: 60 m; Column type: Capillary; CAS no: 120127; Active phase: DB-5; Data type: Lee RI; Authors: Fuentes, M.J.; Font, R.; Gomez-Rico, M.F.; Martin-Gullon, I., Pyrolysis and combustion of waste lubricant oil from diesel cars: Decomposition and pollutants, J. Anal. Appl. Pyrolysis, 79, 2007, 215-226.) NIST Spectra nist ri
      301.3 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 50 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 280 C; End time: 30 min; CAS no: 120127; Active phase: HP-5MS; Carrier gas: He; Phase thickness: 0.33 um; Data type: Lee RI; Authors: Wang, S.-F.; Liu, B.-Z.; Sun, K.-J.; Su, Q.-D., Gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons formed during the pyrolysis of phenylalanine, J. Chromatogr. A, 1025, 2004, 255-261., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.30 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 200 C; End time: 15 min; Start time: 5 min; CAS no: 120127; Active phase: HP-5; Carrier gas: Helium; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Wang, G.; Hou, Z.; Sun, Y.; Liu, Y.; Xie, B.; Liu, S., Investigation of pyrolysis behavior of fenoxycarb using PY-GC-MS assisted with chemometric methods, Chem. Anal., 52, 2007, 141-156.) NIST Spectra nist ri
      301.53 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 60C(2min) =;6C/min =;258C=;2C/min =;300C(4min); CAS no: 120127; Active phase: HP-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Wang, Z.; Li, K.; Lambert, P.; Yang, C., Identification, characterization and quantitation of pyrogenic polycylic aromatic hydrocarbons and other organic compounds in tire fire products, J. Chromatogr. A, 1139, 2007, 14-26., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; CAS no: 120127; Active phase: HP-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Wang, Z.; Li, K.; Lambert, P.; Brown, C.E.; Yang, C.; Hollebone, B.P., Identification and characterization of polycyclic aromatic compounds in tire fire products and differentiation of pyrogenic PAHs from petrogenic PAHs, in Proceedings of the 30th Arctic and Marine Oilspill (AMOP) Technical Seminar. Vol.1, 2007, 61-85.) NIST Spectra nist ri
      301.38 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 90C (1min) =; 10C/min =; 120C =; 4C/min =; 310C (20min); CAS no: 120127; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Zamperlini, G.C.M.; Silva, M.R.S.; Vilegas, W., Identification of polycyclic aromatic hydrocarbons in sugar cane soot by gas chromatography-mass spectrometry, Chromatographia, 46(11/12), 1997, 655-663., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; CAS no: 120127; Active phase: HP-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Wang, Z.; Li, K.; Lambert, P.; Brown, C.E.; Yang, C.; Hollebone, B.P., Identification and characterization of polycyclic aromatic compounds in tire fire products and differentiation of pyrogenic PAHs from petrogenic PAHs, in Proceedings of the 30th Arctic and Marine Oilspill (AMOP) Technical Seminar. Vol.1, 2007, 61-85., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 40 C; End T: 280 C; End time: 5 min; Start time: 2 min; CAS no: 120127; Active phase: DB-5; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Wise, S.A.; Benner, B.A.; Byrd, G.D.; Chesler, S.N.; Rebbert, R.E.; Schantz, M.M., Determination of polycyclic aromatic hydrocarbons in a coal tar standard reference material, Anal. Chem., 60, 1988, 887-894., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 60 m; Column type: Capillary; Heat rate: 3 K/min; Start T: 35 C; End T: 300 C; CAS no: 120127; Active phase: HP-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Marynowski, L.; Pieta, M.; Janeczek, J., Composition and source of polycyclic aromatic compounds in deposited dust from selected sites around the Upper Silesia, Poland, Geol. Q., 48(2), 2004, 169-180.) NIST Spectra nist ri
      301.2 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column type: Capillary; Description: 70 0C (2 min) ^ 30 0C/min -; 150 0C ^ 5 0C/min -; 200 0C ^ 4 0C/min -; 310 0C (5 min); CAS no: 120127; Active phase: 5 % Phenyl methyl siloxane; Data type: Lee RI; Authors: Skrbic, B.; Onjia, A., Prediction of Lee Retention Indices of Polycyclic Aromatic Hydrocarbons by Artificial Neural Networks, J. Chromatorg. A, 1108(2), 2006, 279-284.) NIST Spectra nist ri
      301.69 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; CAS no: 120127; Active phase: DB-5; Carrier gas: He; Data type: Lee RI; Authors: Tong, H.Y.; Centen, J.D.; Karasek, F.W.; Jellum, E.; Helland, P., Identification of Trace Organic Compounds in Dimethyl Sulphoxide Solution Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectrometry, J. Chromatogr., 324, 1985, 373-383., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; CAS no: 120127; Active phase: SE-54; Data type: Lee RI; Authors: Chen, J., GC and GC/MS methods for the analysis of polycyclic aromatic hydrocarbon (PAH) in sediment of the grand canal of China, Toxicol. Environ. Chem., 54, 1996, 69-73., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.3 mm; Column length: 12 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 50 C; End T: 250 C; CAS no: 120127; Active phase: SE-52; Carrier gas: He; Phase thickness: 0.34 um; Data type: Lee RI; Authors: Lee, M.L.; Vassilaros, D.L.; White, C.M.; Novotny, M., Retention Indices for Programmed-Temperature Capillary-Column Gas Chromatography of Polycyclic Aromatic Hydrocarbons, Anal. Chem., 51(6), 1979, 768-773., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.30 mm; Column length: 30 m; Column type: Capillary; CAS no: 120127; Active phase: SE-52; Data type: Lee RI; Authors: Wang, Y.; Peng, P.; Cui, S.; Zhang, Y., Identification of PAH in the Suzhou River bed sediments by GC/MS and PAH retention index system, J. Nanjing Norm. Univ. (Nat. Sci.), 20(2), 1997, 47-68., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; CAS no: 120127; Active phase: DB-5; Data type: Lee RI; Authors: Naikwadi, K.P.; Charbonneau, G.M.; Karasek, F.W.; Clement, R.E., Separation and Identification of Organic Compounds in Air Particulate Extracts by High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectrometry, J. Chromatogr., 398, 1987, 227-237., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column length: 12 m; Column type: Capillary; Heat rate: 3 K/min; Start T: 40 C; End T: 285 C; CAS no: 120127; Active phase: SE-52; Data type: Lee RI; Authors: Boenke, A.; Ballschmiter, K., Fused quinones as retention index marker in high resolution gas chromatography with electron-capture detection (HRGC/ECD) of oxidized aromatic compounds, Fresenius J. Anal. Chem., 327, 1987, 44-45., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column type: Capillary; CAS no: 120127; Active phase: SE-52; Data type: Lee RI; Authors: Shlyakhov, A.F., Gas chromatography in organic geochemistry, Nedra, Moscow, 1984, 221., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column type: Capillary; Heat rate: 2 K/min; Start T: 50 C; End T: 250 C; CAS no: 120127; Active phase: 5 % Phenyl methyl siloxane; Data type: Lee RI; Authors: Skrbic, B.; Onjia, A., Prediction of Lee Retention Indices of Polycyclic Aromatic Hydrocarbons by Artificial Neural Networks, J. Chromatorg. A, 1108(2), 2006, 279-284., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 310 C; Start time: 2 min; CAS no: 120127; Active phase: HP-5; Data type: Lee RI; Authors: Miao, X.; Wu, F., Study on retention behaviors of polycyclic aromatic hydrocarbons by gas chromatography in different operation models, J. Instrumental Anal., 15(4), 1999, 288-292.) NIST Spectra nist ri
      303.03 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.30 mm; Column length: 30 m; Column type: Capillary; Description: 50 0C (2 min) ^ 8 0C/min -; 120 0C (3 min) ^ 10 0C/min -; 230 0C; CAS no: 120127; Active phase: HP-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Cheng, D.-X.; Liu, B.-X.; Sun, Y.-A.; Xie, B.; Zhang, H.-L., rapid analysis of pyrolysis products of cholesterol by GC-MS assited with boiling point – Lee retention index, journal of Instrumental Analysis – Fenxi ceshi xuebao, 24(6), 2005, 85-88.) NIST Spectra nist ri
      301.68 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 6 K/min; Start T: 50 C; End T: 310 C; End time: 10 min; Start time: 1.5 min; CAS no: 120127; Active phase: HP-5; Carrier gas: Helium; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Pedersen, D.U.; Durant, J.L.; Taghizadeh, K.; Hemond, H.F.; Lafleur, A.L.; Cass, G.R., Human cell mutagenes in respirable airborne particles from the Northeastern United States. 2. Quantification of mutagenes and other organic compounds., Environ. Sci. Technol., 39(24), 2005, 9547-9560., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 310 C; Start time: 2 min; CAS no: 120127; Active phase: HP-5; Data type: Lee RI; Authors: Miao, X.; Wu, F., Study on retention behaviors of polycyclic aromatic hydrocarbons by gas chromatography in different operation models, J. Instrumental Anal., 15(4), 1999, 288-292.) NIST Spectra nist ri
      301.37 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 60C(2min) =;15C/min =;180C =;5C/min =;280C (10min); CAS no: 120127; Active phase: LM-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Re-Poppi, N.; Santiago-Silva, M., Polycyclic aromatic hydrocarbons and other selected organic compounds in ambient air of Campo Grande City, Brazil, Atmos. Environ., 39, 2005, 2839-2850.) NIST Spectra nist ri
      301.39 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 60C(2min) =;15C/min =;180C =;5C/min =;280C (10min); CAS no: 120127; Active phase: LM-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Re-Poppi, N.; Santiago-Silva, M., Polycyclic aromatic hydrocarbons and other selected organic compounds in ambient air of Campo Grande City, Brazil, Atmos. Environ., 39, 2005, 2839-2850., Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 60C(2min)=;15C/min=;180C=;5C/min=;280C(5min); CAS no: 120127; Active phase: LM-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Re-Poppi, N.; Santiago-Silva, M.R., Identification of polycyclic aromatic hydrocarbons and methoxylated phenols in wood smoke emitted during production of charcoal, Chromatographia, 55(7/8), 2002, 475-481.) NIST Spectra nist ri
      301.59 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 40 C; End T: 310 C; Start time: 1 min; CAS no: 120127; Active phase: DB-5MS; Phase thickness: 0.5 um; Data type: Lee RI; Authors: Chen, P.H.; Keeran, W.S.; Van Ausdale, W.A.; Schindler, D.R.; Roberts, D.W., Application of Lee retention indices to the confirmation of tentatively identified compounds from GC/MS analysis of environmental samples, Technical paper, Analytical Services Division, Environmental Science;Engineering, Inc, PO Box 1703, Gainesville, FL 32602, 2002, 11.) NIST Spectra nist ri
      301.84 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 40 C; End T: 310 C; Start time: 1 min; CAS no: 120127; Active phase: DB-5MS; Phase thickness: 0.5 um; Data type: Lee RI; Authors: Chen, P.H.; Keeran, W.S.; Van Ausdale, W.A.; Schindler, D.R.; Roberts, D.W., Application of Lee retention indices to the confirmation of tentatively identified compounds from GC/MS analysis of environmental samples, Technical paper, Analytical Services Division, Environme

      Get an explanation on any task
      Get unstuck with the help of our AI assistant in seconds
      New