Gas Questions – Flashcards

Unlock all answers in this set

Unlock answers
question
Purging volume of 0.01m3 applies to which domestic gas meter?:
answer
[image]
question
A landlord must under Regulations have all gas appliances and installation pipework safety checked annually. In addition to this he must keep records of the safety checks carried out for how long?
answer
[image]years from the date of the check
question
What pipe can not be used for gas?
answer
Polyethylene pipe
question
A gas fire fitted to a letter box opening with no identifiable catchment space must be classified as:
answer
At Risk instal[image]lation
question
Installation pipework within the meter box entering the property without a sleeve or seal, how would you classify this installation?
answer
AR[image]
question
When PTFE tpe is used on a threaded gas joint, the tape must overlap by?
answer
50%[image]
question
The device intended to provide isolation for the purpose of servicing appliances is known as a ...
answer
Gas cock
question
What would be used to pinpoint the source of a small gas escape?
answer
L.D.F
question
What is free area required for compartment ventilation of a 23KW net open-flued boiler in which the air will be provided from a room in the building?
answer
Top: 230cm2 Bottom: 460cm2
[image]
[image]
question
A vitiation sensing device works on the principle of:
answer
A flame lifting in a vitiated atmosphere.
question
When an appliance is identified as Immediately Dangerous, the gas operative must in all cases:
answer
Warn the customer of the dangers of using the appliances.

Attach a 'Do Not Use' label.

Take steps to have the appliance disconnected.
question
When a meter is fitted within an outside meter box, the emergency meter control must always be located:
answer
Within the meter box.[image]
question
When carrying out a gas safety inspection how would you classify a steel gas pipe downstream the gas meter inside the property?
answer
[image]
question
What is not a part of tightness testing a low pressure installation?
answer
Standing pressure test
question
What is not applied to Domestic tightness testing?
answer
Meter volume: greater than 16 m3/hr
question
The terminal of a natural draught open flue fitted before 1st Dec 2000 terminates above a roof with a pitch of 45*. The minimum distance above the intersection with the roof must be?
answer
600 mm[image]
question
Which is the minimum concentration of carbon monoxide within the air that will cause occupants to fall victim to coma within a few minutes?
answer
0.4%
question
A free standing range cooker is installed without a stability device
answer
N.C.S
[image]
question
Where gas installation pipes are to be fitted within a floor of solid construction, or under the foundations of a building, they are require?
answer
Protection against failure caused by structural movement.
question
Why does a condensing boiler require condensate water to be drained away from the appliance?
answer
At low temperature vapour constantly produces condensate when boiler is working.
question
What are the differences between a simplex and a duplex burner?
answer
The number of injectors.
question
Unless otherwise stated by the appliance manufacturer, a DFE fire has which of the following ventilation requirements?
answer
Ventilation of 100 cm2 to be provided.
question
What is the purpose of overheat thermostat fitted to a gas boilers?
answer
To provide added protection to the appliance in the event of thermostat failure.
question
Yellow flames are being discharged from an open flued gas boiler burner which has not been serviced for three years. What is the most likely cause of the problem?
answer
The burner is blocked.
question
If the push rod of an instantaneous water heater is bent, this would have the effect of?
answer
Causing the gas to stay on
question
What must be included into the design of a glass fronted fire?
answer
A down draught diverter.
question
What is the purpose of a by-pass port in oven thermostat?
answer
To allow a small flame in the burner first before it comes to full.
question
Technical Bulletin 015 and 022 states that you can install
answer
new gas cookers with FSD

used gas cookers without FSD with manufacturer's instructions

new gas cooker without FSD
question
The gas supply point for a cooker should terminate behind the appliance at a height of approximately?
answer
0.75 m[image]
question
Which gas component should be fitted to the supply to a built-in oven, where a rigid connection is used to connect the oven to the gas supply?
answer
Appliance isolation tap.
question
When a radiant/convector gas fire is to be installed onto a new pre-cast flue, what is the minimum cross sectional area of the flue?
answer
12,000mm2[image]
question
Although less time is desired, the flame supervision device for a gas fire other than DFE when tested should activate within:
answer
180 seconds[image]
question
An immersion heater has a 2500 watt rating at 250 volts. What size circuit protective device is required to protect it?
answer
2500 / 250 = 10 amp[image]
question
The unit of electrical power is measured in ...
answer
Watts[image]
question
On completion of a gas pipework installation the system should be purged. The reason for purging is to..?
answer
remove air and gas/air mixtures prior to use
question
How many starter blocks should be installed on a pre-cast flue system?:
answer
3[image]
question
The installation pipe is positioned...
answer
Downstream of the primary meter.
question
What is the name of the component fitted to a fan assisted boiler which prevents the boiler from operating if the fan fails?
answer
Pressure switch.
question
What is the name of an ignition arrangement for hotplates when gas mixes with air after injector?
answer
Post-aerated
question
If the coil in a calorifier on a combustion chamber split, it will cause the?
answer
Pressure to drop in the system.
question
Yellow flames are being discharged from a grill burner which has not been serviced for 3 years.
What is the possible causes of the problem?
answer
Air ports became blocked.

Cooker's flue way is blocked.

Blocked injectors.
question
When installing a wall mounted gas fire, unless otherwise stated by the manufacturer, the top of the burner must be situated at least:
answer
225mm from the carpet[image]
question
When a gas fire is to be installed into new pre-cast flue blocks, the minimum internal dimension of any part of the flue should be?
answer
125 mm[image]
question
When is it not necessary to fit a flue terminal to a flue system?
answer
When the flue has a diameter greater than 170mm
question
The pressure gauge in a sealed system should be capable of reading which of the following range of pressures?
answer
0 to 4 bar[image]
question
The feed and expansion cistern in an open vented central heating system should be capable of receiving what percentage volume of water from the heating system when heated ?
answer
The cistern should be sized so that it can accommodate about 4% of the contents of the system when heated, this is the approximate volume of expanded water due to the heating of the system
question
A system boiler cannot provide _________ but it will heat a storage cylinder for hot water supply.
answer
instantaneous hot water
question
One method used to give an additional control and economic use of heating systems is to split the system up into separate ____________
answer
heating zones
question
A ____________ is a device which opens or closes in response to signals from a room thermostat or a cylinder stat.
answer
motorized valve
question
Which of the following components is fitted at the high points in pipework in central heating systems?
answer
Automatic air vent
question
What is the likely outcome of rigidly fixing central heating pipework to the notched sections in timber first floor joists?
answer
Expansion and contraction noise
question
The type of heating system that uses 2 x two port motorised valves is known as a ?
answer
S plan
question
A heating circuit in which the flow and return pipes are completely separated until they connect to the boiler is known as a?
answer
Two Pipe System
question
What is the recommended maximum clip spacing distance for a vertical 15 mm copper pipe?
answer
The maximum clip spacing distance for 15 mm vertically clipped copper pipe is 1800 mm.
question
Which one of the following pipework materials is not permitted to be installed in a new cold water system?
answer
Lead[image]
question
Flame supervision devices (FSD)
answer
FSD is a general term for any device designed to stop gas going to the burner if the flame is extinguished.
This is to prevent a dangerous build up of gas within the appliance, its flue or the room.
question
Whilst completing the internal 26(9) Visuals on a gas appliance the engineer checks off his (C)
Combustion List which includes;
answer
Injector, Mixing Tube, Burners, and Heat Shields
question
Ventilation for a flueless gas hob or cooker is dependant on ?
answer
The room volume, and openable window or similar.
question
The installation of a CO void monitoring safety shut-off system (COSSVM) and regular service/maintenance by a registered engineer can be used instead of inspections hatches to confirm the integrity of a concealed room-sealed fan-draught boiler chimney/flue system if…
answer
it is an existing installation and the boiler was installed before 1st of January 2013
question
What is the likely fault if a cooker oven bumer extinguished after a period of approximately 15 minutes?:
answer
Blocked oven thermostat by-pass
question
A likely cause of excessive working pressure at a gas fire or cooker is:
answer
An incorrectly adjusted meter governor.
question
When double wall flue pipes are run externally it is important, in order to prevent condensation, to ensure the flue length does not exceed:
answer
28 meters[image]
question
You find a propane cylinder stored within a dwelling, how would you classify this situation?
answer
A.R[image]
question
When an Extract fan causes spillage of combustion products from an open flued appliance, additional air ventilation may be required to remedy the problem, this is provided by...
answer
A permanent vent.
question
When de-commissioning sections of gas installation pipework, the plumber must ensure that gas contained in the pipework is?
answer
Fully purged.
question
After completing the installation of a gas appliance the next operation should be to?
answer
Test for tightness.
question
Where a gas installation pipe work exits premises to serve remote external appliances, the correct location for an external control valve is?
answer
In an accessible position externally at the point where the pipe exits the premises.
question
On a gas installation supply when carrying out gas work in the tra
service valve and gas control), the engineer on completion must
answer
test for gas tightness using a manometer or Leak Detection Fluid
question
Of the 3 areas that gas work can be completed on a gas installation which requires a tightness test on
completion of this work using LDF only with gas flowing is
answer
The appliance internal supply between the gas control and injectors
question
The only components of a gas installation that are expected to escape gas inside the allowed
tolerances are the
answer
appliance gas controls
question
The gas appliance Reg 26(9) Internal checks are otherwise known as
answer
the appliance gas safety inspection ventilation, fluing, combustion, ignition controls
question
A Safety Test on a gas appliance must confirm
answer
Correct Ventilation, Fluing, Combustion, and safety device operation
question
When completing our internal 26(9) service inspection appliance checks we have to isolate the
electrics. How would we test that this has been completed safely
answer
Isolating at plug or fused spur, Using a voltmeter, carry out polarity checks with the power on and
off to confirm correct isolation and polarity
question
Prior to completing the internal 26(9) service checks on a gas appliance we would
answer
safely isolate the gas and electrics
question
When completing the internal 26(9) service gas safety appliance service inspection on a gas appliance
the (V) Ventilation checks are to
answer
confirm that the airways from the appliance air inlet area to the mixing area are clear
question
When completing the internal 26(9) gas safety checks on a gas appliance the (I)
include amongst checking spark electrode condition and gaps, the checking of
answer
safety devices for correct installation and condition
( ) overheat stats
( ) flame supervision devices
question
When completing the internal 26(9) checks on a gas boiler the engineer commences his (F) Fluing
Visuals. Which of the following is 'NOT' on of the internal flue visuals
answer
Combustion Heat Shields
question
Whilst completing the internal 26(9) Visuals on a gas appliance the engineer checks off his (C)
Combustion List which includes;
answer
Injector, Mixing Tube, Burners, and Heat Shields
question
After completing a gas repair on a gas appliance the engineer starts by completing the internal checks,
and once satisfied moves onto the external safety checks. Starting with (V) Ventilation the engineer
answer
Checks the sizes and type of vents installed at the property including the ventilation path to the
appliance is correct
question
An Engineer is working on an open flued gas back boiler and fire unit. Having completed the service,
the appliance is put back together and the engineer commences the safety checks. As part of these the
engineer proceeds to complete the fluing checks, these include checking the flue terminal type and
position, also
answer
checking the conformity and design of the flue before completing a flue flow and spillage test
question
An engineer has finished doing the internal service checks on a gas oven, and turns the gas and
electrics back on. After checking the Ventilation and Combustion requirements and provision the
engineer proceeds to check the ignition and safety devices. There is a liquid expansion flame
supervision device in the oven. The engineer will need what equipment to complete the test?
answer
Eyes Only[image]
question
What part of the internal service/commission checks does checking the flue hood of a gas boiler for
cracks fall under
answer
Internal Fluing
question
Checking the heat exchanger for blockages on a gas boiler forms part of the
answer
internal fluing checks
question
Checking that the thermostat phial on an old boiler is securely fitted into its pocket forms what par
your checks
answer
Internal Ignition/safety device
question
Checking the injectors for any visual blocks is covered by
answer
Internal Ignition/safety device
question
Checking that a vent is correctly sized covers what part of the inspection
answer
External Ventilation
question
Checking the flame picture is required to confirm
answer
Correct Air Gas Mix
question
Completing a spillage test is most commonly required on
answer
a conventional flue natural draught appliance
question
An engineer is checking the room volume allowances for a flueless gas water heater. Which check is he
doing
answer
Ventilation
question
An engineer is gas rating a gas appliance. What check is he doing
answer
confirming the appliance is consuming the correct amount of gas
question
An engineer is doing a gas tightness test at the meter 60 seconds after extinguishing the pilot on the
boiler. What test is he doing
answer
checking the flame failure device has actually closed safely
question
What is not a gas fitting?
answer
Gas Service Pipe
question
Which is to be regarded as WORK in relation to gas fitting?
answer
Permanently adajusting or altering gas fitting
question
Which Regulation clearly defined the type of property the Regulations do not apply to?
answer
Regulation 2.4[image]
question
Which of the following premises do the Regulations apply to when gas is supplied through a distribution main?
answer
Premises used for sleeping accomodation
question
Employers are responsible for ensuring the competence of gas fitting operatives who they employ
answer
True.[image]
question
Which Regulation prohibits any person falsely pretending to be a member of a class of persons approved by the HSE.
answer
Regulation 3.7[image]
question
Gas pipes entering a building through a brick wall can do so without using sleeve, providing both sides of the wall through which the pipe passes are sealed with fireproof mastic.
answer
False[image]
question
Regulation 6 deals specifically with general safety precautions for persons carrying out work in relation to gas fitting.
answer
True[image]
question
Normally, as defined in these Regulations, unattended in relation to domestic premises means absent from the premises
answer
TRue[image]
question
Which Regulation states that a separate notice must be prominently displayed indicating when the emergency control is open or closed?
answer
Regulation 9.2[image]
question
Which Regulation states that installers must notify the responsible person where permament bonding is required but not connected?
answer
Regulation 18.2[image]
question
Regulation 20 deals with the protection of buildings whilst installing pipework.
answer
Tru[image]e
question
Prior to the installation of any appliance, a person providing a gas supply to a domestic pipework installation for the first time is responsible for;
answer
testing and purging the whole pipework installation
question
Regulation 34 of The Gas Safety (Installation and Use)Regulations, who has to be initially informed when you identify an appliance which is failing to discharge its products of combustion safely?
answer
The person responsible for the premisis
question
The acceptable jointing compounds/material for use on gas pipework with all screwed joints up to 28mm are:
answer
PTFE tape to BS 6974, jointing paste to BS 5292
question
The maximum interval for supports for 25mm mild steel pipe in horizontal run is:
answer
: 2.5m[image]
question
An emergency control should be:
answer
labelled or marked to show its open and closed positions, easy to operate and fitted with a suitable handle, which is securely attached, or other permanent means of operation.
question
Low burner pressure at an appliance could create
answer
Too low an efficiency
question
If the oxygen around a flame is reduced by 25% what are the main constituents of incomplete combustion.
answer
Carbon monoxide and water vapour
question
ventilation requirement for combustion air direct to outside for an open flued gas boiler with a rated input of 15 kW fitted in a room is:
answer
40cm2
question
An open flued boiler with a maximum net input of 18kW is fitted in a compartment with high and low ventilation to an internal space. The minimum free area of high level ventilation must be
answer
HIGH LEVEL;180 cm2
question
Where a person performs work in relation to a gas appliance, he must immediately examine, among other things, the effectiveness of the flue system. If the flue is found to be faulty, the action which the Regulations require to be taken is?
answer
Notify the responsible person and where different, the owner, of the appliance.
question
On a Medium to Low pressure meter box installation, where must the outlet pipework and vent exit through?
answer
The base of the box.
question
An appliance heat exchanger is blocked with soot and the flame picture is very poor. Would this appliance be:
answer
I.D[image]
question
The initial signs of someone suffering from carbon monoxide poisoning are likely to be?
answer
Severe headache and convulsions
question
What is the free area required for compartment ventilation of a 23kW net open-flued boiler in which the air will be provided from a room in the building?
answer
Top: 23x10=230cm2
Bottom: 23x20=460cm2
[image]
[image]
question
What action should be taken when you have classified an appliance as at risk?
answer
Turn off the appliance with customer permission[image]
question
Which installation within a tenanted property would contravene The Gas Safety (Installation and Use) Regulations?
answer
A back boiler and fire with adequate ventilation fitted in a lounge that has been used as a bedroom since January 2001.
question
What is the minimum length a Temporary Continuty Bond should be?
answer
1200mm
question
The minimum cross sectional area of a new flue block system for a gas fire must be
answer
16,500mm2 with no dimension less than 90mm.
question
TB 008 (Edition 3) provides guidance to gas engineers to assist them in meeting the requirements of Regulations when working on:
answer
Existing concealed room-sealed fanned draught boiler chimney/flue systems in domestic premises.
question
The maximum distance between 22mm light gauge copper pipe supports for internal horizontal runs is?
answer
2.0 meter[image]
question
Is it acceptable to site wall units above a built-in hob within a vertical height of 800 mm of the hob?
answer
Yes. Min 760 mm of clearance are required.
question
What control device is not incorporated into a standard multifunctional control valve fitted to a gas boiler?
answer
Weep line
question
When carrying out a gas safety inspection how would you classify a steel gas pipe downstream the gas meter inside the property?
answer
OK[image]
question
If an open flued boiler with a rated input of 23.31 kW (gross) is installed within a room, the ventilation requirement is?
answer
70 cm2
question
A heat shield adjacent to plastic gutters needs to be fitted due to the close proximity of flue terminals. The heat shield should be a minimum lenght of?
answer
1m
question
A free standing range cooker is installed without a stability device
answer
NCS[image]
question
When a gas flue block system is to be connected to a terminal above the roof or at the ridge using flue pipe, the flue should have a minimum diameter of;
answer
125mm[image]
question
When a gas flue block system is to be connected to a terminal above the roof or at the ridge using flue pipe, the flue should have a minimum diameter of;
answer
125mm[image]
question
A simple way of testing a flame failure device on a gas appliance is to shut off the service valve to allow the pilot to extinguish.
Would this be acceptable on a gas fire isolated by a restrictor elbow ?
answer
No, when the restrictor is closed down there is an escape of gas which could be ignited[image]
question
Immediately After refitting a burner pressure test nipple following tests on a gas appliance the test point must be tested for
tightness using LDF only when
answer
the appliance burners have been turned back on
question
After carrying out burner pressure test, and in the absence of any Leak detection fluid, would a gas tightness test at the meter
test point identify whether the test point has been adequately sealed
answer
No[image]
question
When servicing a radiant brick convector gas fire the closure plate..should?
answer
be removed to inspect the catchment area
question
When servicing a gas oven, it is necessary when visually inspecting its condition to check in addition to the condition of the
burners, and injectors where possible, the
answer
Path of combustion air into the appliance, and combustion product path out of the combustion area into the room or flue
question
When servicing a gas appliance using the manufacturer's manual the burner pressure will
answer
not confirm the appliance heat input is correct
question
When gas commissioning a modern gas boiler with forced draught burners the manufacturer will most commonly require you
check the inlet working / operating pressure, gas rate and
answer
Flue gas analysis
question
When servicing any fuel effect fire it is essential that the manufacturers manual is present to ensure amongst other things that
answer
The coals are re-fitted correctly to ensure proper airation and flame picture
question
When carrying out a service inspection on a balanced flue space heater it is essential that we check the viewing glass and heat
exchanger for cracks or holes to primarily prevent
answer
combustion gasses coming back into the room
question
Prior to carrying out a service/inspection on a gas boiler, what external visual checks should be completed
answer
Combustion air requirement and provision, location, and signs of distress, Fluing requirements and provision
question
When inspecting the grill burner of many hobs what are we visually inspecting?
answer
Flame Picture, Burner condition, air path in and combustion exhaust path clearance
question
In terms of ventilation for a flueless cooking appliance what is the minimum room volume permissible without a purpose
provided vent so long as an openable window is present?
answer
10m3
question
When testing the oven thermostat it is essential that
answer
The flame remains at maintenance level and doesn't extinguish when the oven temperature has been reached
question
What is the purpose of the flame supervision device on a gas oven burner assembly
answer
To prevent the oven filling with a dangerous level of gas during the lighting process
question
On a hotplate fitted with a flame failure safety device, what is the maximum permissible shut off time you would permit in th e
absence of the manufacturers instructions ?
answer
90 seco[image]nds
question
The most common safety tests you may carry out on a gas hotplate are?
answer
Burner pressures, High and low flame stability, flame pic, control tap ease of movement and shut off, shut off device on any
glass lid when closed
question
What is the minimum permissible distance alongside a tall cupboard that a gas hob can be installed?
answer
50mm[image]
question
What is the minimum permissible distance between a grill hood and any heat sensitive materials above (i.e. cupboard)?
answer
610mm[image]
question
How far should a stability bracket extend into the rear retaining slot of a cooker to be useful?
answer
Approx 90mm
[image]
question
Which of the following is not directly relevant to the safe installation of a natural gas cooking appliance?
answer
A Carbon Monoxide Detector should be installed when a Range Cooker is installed
question
Unless the manufacturer states otherwise and in order for this DFE appliance to safely and adequately clear its products of
combustion what is the required amount of purpose provided ventilation ?
answer
100cm2[image]
question
When installing a hearth for a gas fire installation the following dimensions apply
answer
Thickness 12mm, Depth 150m, Edge of fire to edge of hearth 300mm, Height around edge 50mm
question
A purpose provided Hearth must?
answer
Have a thickness no less than 12mm to avoid heat transfer of over 80 degrees C.
question
A spillage test on the open flued gas fire is to confirm the adequate and safe removal of combustion products from the applia nce
through the flue system to the external air. The appliance must be tested for spillage.
answer
Strictly in accordance with the manufacturers instruction
question
What is the minimum permissible distance between a fire spigot and the chair brick or Catchment rear wall
answer
50mm[image]
question
Where the flue spigot on a fire needs extending, the length of any such extension must not exceed how far beyond the rear of
the fire
answer
150mm[image]
question
Where a single walled flue pipe is subject to the formation of condensation caused by products of combustion, the problem may be prevented by
answer
Replacing the single-walled flue pipe with insulated twin-wall flue pipe
question
Where a guard has been sited to a chimney to stop the problems caused by nesting birds, the guard shall have openings of not more than...
answer
20mm[image]
question
In addition to sealing the flue liner within a builders opening, it is also essential that any other gaps, such as side entry pipework and any holes must also be sealed to prevent which of the following from occurring
answer
Flame distortion caused by excessive air movement under the fire
question
Push-fit fittings shall conform to which of the following British Standards
answer
BS 669 - 1 or BS 7838
question
Where pipework carrying gas is installed within timber construction walls, it must be...
answer
Constained within purpose-designed channels or ducts
question
Where the domestic installation pipe size exceeds 35 mm copper, DN32 steel or the installation volume exceeds 0.035mA? the procedure for gas tightness testing can be found in:
answer
IGE/UP/1 or IGE/UP/1[image]
question
When purging installations with an installation volume exceeding 0.02m?...
answer
Continually attempt to ignite the purge mixture at an open burner
question
When a decorative fuel effect fire is installed in a room which also contains oil or solid fuel appliances, these appliances...
answer
Shall be treated as if they are gas appliances
question
Where an air vent providing combustion air to an appliance is fitted either in the floor or the ceiling, the underfloor or roof space with which the vent communicates
answer
Must contain ventilation of at least the same free area fitted direct to outside
question
The recommended methods of notification and notification criteria for 'Not to current standards (NCS) are...
Which of the following statements is false?
answer
When notifying categories 1 & 2 situation, it is recommended this be done orally
question
If the correct warning notice is not fitted to a primary meter, the gas operative must inform the ..?
answer
The gas transporter.
question
Range rated appliances must incorporate which component within their design?
answer
A constant pressure governor.
question
Which of the Gas Safety Regulations compels the operative to use a temporary continuity bond where necessary?
answer
Regulation 10.[image]
question
What is the approximate volume of air required to completely burn 5 m3 of natural gas?
answer
50 m3
question
Which is the minimum concentration of carbon monoxide within the air that will cause occupants to fall victim to coma within a few minutes?
answer
0.4%.
question
The ventilation requirement for open flued appliances is dependent upon..?
answer
Heat input
question
If the correct warning notice is not fitted to a primary meter, the gas operative must inform the..?
answer
The gas transporter.
question
The purpose of the top vent installed within a compartment is to?
answer
Remove warm air for cooling.
question
E6 Meter
28mm Pipe
Existing with appliances connected
Allowable Pressure Drop is
answer
8[image]mb
question
E6 Meter
28-35mm
Existing with appliances connected
Allowable Pressure Drop is
answer
4mb[image]
question
U6/G4
28mm
Existing with appliances connected
Allowable Pressure Drop is
answer
4mb[image]
question
U6/G4
28-35
Existing with appliances connected
Allowable Pressure Drop is
answer
2[image].5mb
question
U16/G10
28mm
Existing with appliances connected
Allowable Pressure Drop is
answer
1mb[image]
question
U16/G10
35mm
Existing with appliances connected
Allowable Pressure Drop is
answer
1mb[image]
question
New Installations
With or without appliances
answer
NPM on gauge
No smell of gas[image]
question
Existing
(Pipework only)
answer
NPM ON THE GAUGE
NO SMELL OF GAS[image]
question
It is a legal requirement to install gas appliances in accordance with the manufacturers instructions. Which regulation states this?
answer
Regulation 33[image]
question
A Gas Cooker or Hob Can be Installed in a Bedroom (Bed Sit). However the room volume must....
answer
exceed 20m3
question
Riddor regulation 11(1) requires any ID incidents to be reported within
answer
2 hours of attending an incident and reported online within 14 days
question
In order to avoid condensation, twin wall flue pipes with only an air gap for insulation, should not be used externally for lengths in excess of?
answer
3m[image]
question
If the correct warning notice is not fitted to a secondary meter, the gas operative must inform....?
answer
The occupier and/or landlord
question
What action should be taken when you have classified an appliance as at risk?
answer
Turn off the appliance with customer permission
question
You have been called to a fanned draught boiler which heats up to approximately 50oC. The appliance then 'cuts out' and will not re-light without manual re-setting. The control thermostat is set at 70oC and appears to be operating adequately. What is the likely cause of the problem?
answer
Overheat thermostat is faulty.
question
A flueless heater is to be installed in a conservatory measuring 3.0 m x 2.5 m x 2.4 m. Calculate the maximum rated input of heater which may be installed:
answer
0.81 kW
question
Open Flued Appliance COMPARTMENT Venting to OUTSIDE
answer

High Level 5cm2/kW Low Level 10cm2/kW

In Room-NIL

[image]
question
Open Flued Appliance
COMPARTMENT
Venting to ROOM
answer
High Level 10cm2/kW
Low Level 20cm2/kW
Room Vent-Max Heat Input(net)-7kW x 5cm2[image]
question
Open Flued Appliance
ROOM
answer
Max Heat Input(Net)-7kW x 5cm2
question
Room Sealed Appliance
COMPARTMENT
Venting to OUTSIDE
answer
High Level-5cm2/kW
Low Level -5cm2/kW
In Room-NIL[image]
question
Room Sealed Appliance
COMPARTMENT
Venting to ROOM
answer
High Level 10cm2/kW
Low Level 10cm2/kW
In Room-NIL[image]
question
Room Sealed Appliance
Room
answer
No Vent Required[image]
question
Ventilation
NET Heat Input Value
answer
Divide the gross value by 1.1
question
Adventitious Ventilation
answer
Air that can leak into buildings through windows,doors,floorboards walls etc
question
DFEF
answer
No allowance can be made for adventitious ventilation
question
Intumescent Air Vent
answer
Specially designed to prevent spread of fire.
Normally an insert with metal framework,open latticework of heat sensitive material
question
Design width of Vent grill
answer
Permits entry of a ball of 5mm diameter
but prevents entry of a ball of 10mm diameter
question
Installation of a vent in internal wall or door
answer
No greater than
450mm from floor level
question
Fluess appliance ventilation requirements
answer
Consult M.Is
or table in BS5440-2
Any air vent required must be direct to outside
question
Ventilation for flueless space heater in a ROOM
answer
1.Convert kW to Watts by x the net heat input by 1000
2.Then DIVIDE by the volume of the room
Answer must be 45W/m3 or less
question
Gas Fired Appliances
Minimum Flue Diameter is
answer
125mm[image]
question
An existing gas appliance whose ventilation and fluing requirements are found to comply with the British Standards but not with the MI (Manufacturers Installation Instructions) Is deemed ....?
answer
Unsafe for use
question
Manufacturers Installation instructions primarily have priority over the British Standards
answer
True[image]
question
It is a legal requirement to install gas appliances in accordance with the manufacturers instructions. Which regulation states this?
answer
Regulation 33 [image]
question
How would you categorise a Flexible gas connection on a flued appliance?
answer
AR (at risk)[image]
question
How would you categorise.. Pipework failing a gas tightness test ?
answer
ID (immediately dangerous)[image]
question
When faced with an Immediately Dangerous installation, The GIUSP states that if the customer does not agree to the installation being disconnected, the engineer should...
answer
Report it immediately to the ESP and obtain the ESP's reference number
question
Riddor regulation 11(2) Requires gas registered business and engineers to report...
answer
Immediately dangerous situations that pose a threat to life, consciousness or lead to hospitalisation
question
Purpose provided ventilation for a flueless appliance must communicate directly with the outside air, whether
directly or via a duct.
answer
[image]
question
what category of unsafe classification would you place a flueless gas cooker installed in a kitchen 7M3 with
an openable window no openable door to outside and no additional ventilation provision.
answer
AR[image]
question
When installing a gas pipe within a builders opening it is required to be?
answer
protected against corrosion [image]
question
Complete combustion of natural gas results in the production of??
answer
[image]
question
'It is a contravention of The Gas Safety (Installation and Use) Regulations to falsely pretend to be a member of a class of persons approved by the Health and Safety Executive'. Is this statement True of False?
answer
[image]
question
The minimum volume (or capacity) of the catchment space for an inset type of gas fire, fitted to a lined masonry chimney, previously used for a gas appliance is:
answer
0.002m3 (2 litres)
question
Double walled metallic flue systems used for gas appliances should comply with EN 1856 and may be manufactured with an aluminium inner liner True or False?
answer
[image]
question
During a routine inspection of a gas appliance a dangerous fault is located. Which Regulation defines the procedures to follow
answer
[image]Regulation 34
Get an explanation on any task
Get unstuck with the help of our AI assistant in seconds
New