Safety Devices and Controls – Flashcards
Unlock all answers in this set
Unlock answersquestion
Controls FLAME SUPERVISION |
answer
Thermoelectric Flame rectification Vapour Pressure |
question
Controls FLOW |
answer
Taper plug Valve Ball Valve Solenoid |
question
Controls IGNITION |
answer
Permanent Pilot Electronic/electrical Hot Surface |
question
Controls PRSSURE |
answer
Simple Regulator Modulating Regulator Air/Gas Ratio Control Valve |
question
Controls Safety |
answer
TTB Interrupted thermocouple Vitiation Sensing Pressure Switch Hi-Limit stat |
question
Controls Temperature |
answer
Liquid Expansion Thermostatic Switch Thermistors Bi metallic Switch Rod Type Wax Capsule |
question
FSDs that have a max operating time of 180seconds |
answer
SPACE HEATER |
question
FSDs that have a max operating time of 45 seconds |
answer
Storage water heater 35-70kW |
question
FSDs that have a max operating time of 50 seconds |
answer
Storage Water Heater <35kW |
question
FSDs that have a max operating time of 60seconds |
answer
Central Heating Boilers Cooker Ovens DFE W.A.U 60kW gross Combi/Multipoint WH |
question
FSDs that have a max operating time of 90seconds |
answer
COOKER HOTPLATE |
question
Flame Supervision Devices Flame Rectification (Ionisation) |
answer
Electronic method of FSD,very quick acting. Principle: Within a flame there are positively charged particles called IONS These can conduct an electrical current. But will only happen when a flame is present. |
question
Flame Supervision Devices Thermo-Electric |
answer
Principle:Same as thermocouple. Small Electromagnet spring loaded Main Valve Interrupter Valve Thermocouple |
question
Flame Supervision Devices Thermo-Electric "CLICK TEST" |
answer
1.With MAIN BURNER operating 2.Isolate the gas supply at A.I.V 3.Check time taken for thermoelectric,magnetic valve to close. 4.After close of valve,Restore gas supply at A.I.V 5.Check there is no gas at the burner before relighting the appliance |
question
Flow Control Gas Taps |
answer
Used to control throughput of gas fires n cookers Consist of taper plug held in position by compression spring. |
question
Flow Controls Ball Valves |
answer
Commonly used for isolating appliances, and as ECVs. Maintainance free ,cannot be repaired |
question
Flow Controls Fire pedestal elbow |
answer
Consists of Washer or O ring,attached to disc,which is then driven onto a seat by means of a screw thread or spring. |
question
Flow Controls Self sealing valves |
answer
(Bayonet plug in sockets) Used in conjunction with flexible gas pipes for cookers. |
question
Flow Controls Solenoid Valves |
answer
Electrically controlled gas valve,normally constructed so as to be normally closed. "copper wire on a bobbin" purpose is to turn on or off a gas supply by electrical means. |
question
Flow Controls Taper Plug Valves |
answer
Normally consists of tapered brass or aluminium plug. Valve is operated manually by means of a handle |
question
Flow Controls Cooker Lid Safety Shut-Off Valve(SSOV) |
answer
Unique to gas cookers with drop down lids. If the lid is dropped without the hotplate burners being turned off. This valve will extinguish the burners |
question
Flow Controls Self Sealing Disc on Seat Valve |
answer
AKA Bayonet plug in sockets. Used with flexible gas pipes. For Cookers and tumble dryers |
question
How a Thermocouple works |
answer
when two dissimilar metals are joined together at one end and heated a small electric current is generated. When tip of thermocouple is heated by a flame,(normally pilot),this generates small electric current,which is transmitted to control. |
question
Main Purpose of Controls into catagories |
answer
Gas Pressure Regulation Flow Control Temperature Flame Supervision Multifunctional System Monitoring/safety |
question
Temperature Control Liquid Expansion Thermostatic Switch |
answer
Positioned where the temp is to sensed. 1)spring loaded electrical contacts 2)When Contacts separate(due to liquid expansion)current flow stops 3)this switch controls gas flow by switching a solenoid gas valve on and off 4)found on trad CH boilers and combi boilers 5)PHIAL is located within the top of the heat exchanger |
question
Temperature Control Liquid Expansion Thermostatic Valve |
answer
Principle:Liquid when heated expands Liquid contained in a PHIAL Flexible Metal Bellows Capillary Tube Most commonly found on gas cooker ovens |
question
Temperature Control Thermistor |
answer
Do not contain any moving parts. Contain materials which when heated either decrease or increase in electrical resistance. This can be monitored by a PCB to activate an electrical solenoid to control flow of gas to a burner |
question
Temperature Control Thermo Disc |
answer
Contained in a plastic housing,ativated by a bi-metallic disc. Disc will flex at predetermined temp Used on ch boilers,W.A.U and tumble dryers |
question
Temperature Control Thermostatic valves and switches |
answer
Purpose is to automatically maintain or limit the temp of a given situation. eg air temp,water temp etc |
question
Which is the most common type of flame supervision device is fitted to domestic cooker ovens? |
answer
Liquid Expansion |