Bromobenzene C6H5Br structure – Flashcards
Flashcard maker : Anthony Richie
Contents
Molecular Formula | C6H5Br |
Average mass | 157.008 Da |
Density | 1.5±0.1 g/cm3 |
Boiling Point | 154.2±9.0 °C at 760 mmHg |
Flash Point | 51.1±0.0 °C |
Molar Refractivity | 33.9±0.3 cm3 |
Polarizability | 13.5±0.5 10-24cm3 |
Surface Tension | 35.5±3.0 dyne/cm |
Molar Volume | 105.6±3.0 cm3 |
- Experimental data
- Predicted – ACD/Labs
- Predicted – EPISuite
- Predicted – ChemAxon
- Predicted – Mcule
- Experimental Physico-chemical Properties
-
Experimental Melting Point:
-31 °C Alfa Aesar -30.6 °C Jean-Claude Bradley Open Melting Point Dataset 20491 -31 °C Jean-Claude Bradley Open Melting Point Dataset 14025, 15630, 6576 -31 °C Alfa Aesar A11407 -31 °C SynQuest 1600-9-01 -31 °C Oakwood BR1026 -31 °C LabNetwork LN00194621 -
Experimental Boiling Point:
155-156 °C Alfa Aesar 155-156 °C Alfa Aesar A11407 155-156 °C SynQuest 1600-9-01 156 °C Oakwood BR1026 156 °C LabNetwork LN00194621 -
Experimental Flash Point:
51 °C Alfa Aesar 51 °C Alfa Aesar 51 °F (10.5556 °C)
Alfa Aesar A1140751 °C SynQuest 1600-9-01 51 °C Oakwood BR1026 51 °C LabNetwork LN00194621 -
Experimental Gravity:
1.494-1.496 g/mL / 20 °C Merck Millipore 801786 20 g/mL Merck Millipore 1299 20 g/l Merck Millipore 1299, 801786 1.492 g/mL Alfa Aesar A11407 1.492 g/mL SynQuest 1600-9-01 1.491 g/mL Oakwood BR1026 -
Experimental Refraction Index:
1.559 SynQuest 1600-9-01
-
- Miscellaneous
-
Safety:
10-38-51/53 Alfa Aesar A11407 3 Alfa Aesar A11407 61 Alfa Aesar A11407 DANGER: FLAMMABLE, irritates skin, eyes, lungs Alfa Aesar A11407 Flammable/Irritant SynQuest 1600-9-01 H226-H315-H411 Alfa Aesar A11407 P210-P280-P303+P361+P353-P362-P403+P235-P501a Alfa Aesar A11407 Warning Alfa Aesar A11407
-
- Gas Chromatography
-
Retention Index (Kovats):
1000 (estimated with error: 62) NIST Spectra mainlib_291408, replib_5387, replib_190208, replib_227767, replib_379207 914.7 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 5 m; Column type: Packed; Start T: 80 C; CAS no: 108861; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Righezza, M.; Hassani, A.; Meklati, B.Y.; Chretien, J.R., Quantitative structure-retention relationships (QSRR) of congeneric aromatics series studied on phenyl OV phases in gas chromatography, J. Chromatogr. A, 723, 1996, 77-91.) NIST Spectra nist ri 923.7 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 5 m; Column type: Packed; Start T: 90 C; CAS no: 108861; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Righezza, M.; Hassani, A.; Meklati, B.Y.; Chretien, J.R., Quantitative structure-retention relationships (QSRR) of congeneric aromatics series studied on phenyl OV phases in gas chromatography, J. Chromatogr. A, 723, 1996, 77-91.) NIST Spectra nist ri 924 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 5 m; Column type: Packed; Start T: 100 C; CAS no: 108861; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Righezza, M.; Hassani, A.; Meklati, B.Y.; Chretien, J.R., Quantitative structure-retention relationships (QSRR) of congeneric aromatics series studied on phenyl OV phases in gas chromatography, J. Chromatogr. A, 723, 1996, 77-91.) NIST Spectra nist ri 932 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 5 m; Column type: Packed; Start T: 110 C; CAS no: 108861; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Righezza, M.; Hassani, A.; Meklati, B.Y.; Chretien, J.R., Quantitative structure-retention relationships (QSRR) of congeneric aromatics series studied on phenyl OV phases in gas chromatography, J. Chromatogr. A, 723, 1996, 77-91.) NIST Spectra nist ri 934.8 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 5 m; Column type: Packed; Start T: 120 C; CAS no: 108861; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Hassani, A.; Meklati, B.Y., Gas chromatographic behaviour of monosubstituted benzenes, benzaldehydes and acetophenones on OV polymethylphenyl-silicone stationary phases, Chromatographia, 33(5/6), 1992, 267-271.) NIST Spectra nist ri 964 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 3 m; Column type: Packed; Start T: 180 C; CAS no: 108861; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb A AW; Data type: Kovats RI; Authors: Oszczapowicz, J.; Osek, J.; Ciszkowski, K.; Krawczyk, W.; Ostrowski, M., Retention Indices of Dimethylbenzamidines and Benzylideneamines on a Non-Polar Column, J. Chromatogr., 330, 1985, 79-85., Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 3 m; Column type: Packed; Start T: 180 C; CAS no: 108861; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W AW; Data type: Kovats RI; Authors: Oszczapowicz, J.; Osek, J.; Dolecka, E., Retention indices of dimethylformamidines, dimethylacetamidines and tetramethylguanidines on a non-polar column, J. Chromatogr., 315, 1984, 95-100.) NIST Spectra nist ri 945 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 3 m; Column type: Packed; Start T: 150 C; CAS no: 108861; Active phase: SE-30; Carrier gas: Ar; Substrate: Gas Chrom Q (80-100 mesh); Data type: Kovats RI; Authors: Tiess, D., Gaschromatographische Retentionsindices von 125 leicht- bis mittelfluchtigen organischen Substanzen toxikologisch-analytischer Relevanz auf SE-30, Wiss. Z. Wilhelm-Pieck-Univ. Rostock Math. Naturwiss. Reihe, 33, 1984, 6-9.) NIST Spectra nist ri 960 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 3.3 m; Column type: Packed; Start T: 130 C; CAS no: 108861; Active phase: C78, Branched paraffin; Carrier gas: He; Data type: Kovats RI; Authors: Dallos, A.; Sisak, A.; Kulcsar, Z.; Kovats, E., Pair-wise interactions by gas chromatography VII. Interaction free enthalpies of solutes with secondary alcohol groups, J. Chromatogr. A, 904, 2000, 211-242.) NIST Spectra nist ri 931.71 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Start T: 70 C; CAS no: 108861; Active phase: DB-5; Carrier gas: N2; Phase thickness: 1.5 um; Data type: Kovats RI; Authors: Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 86, 1996, 63-75.) NIST Spectra nist ri 941.36 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Start T: 90 C; CAS no: 108861; Active phase: DB-5; Carrier gas: N2; Phase thickness: 1.5 um; Data type: Kovats RI; Authors: Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 86, 1996, 63-75.) NIST Spectra nist ri 952.2 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Start T: 110 C; CAS no: 108861; Active phase: DB-5; Carrier gas: N2; Phase thickness: 1.5 um; Data type: Kovats RI; Authors: Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 86, 1996, 63-75.) NIST Spectra nist ri 979.6 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 2 m; Column type: Packed; CAS no: 108861; Active phase: Apiezon M; Substrate: Chromosorb W; Data type: Kovats RI; Authors: Jalali-Heravi, M.; Garkani-Nejad, Z., Prediction of gas chromatographic retention indices of some benzene derivatives, J. Chromatogr., 648, 1993, 389-393.) NIST Spectra nist ri 973.7 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 5 m; Column type: Packed; Start T: 120 C; CAS no: 108861; Active phase: OV-3; Carrier gas: N2; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Hassani, A.; Meklati, B.Y., Gas chromatographic behaviour of monosubstituted benzenes, benzaldehydes and acetophenones on OV polymethylphenyl-silicone stationary phases, Chromatographia, 33(5/6), 1992, 267-271.) NIST Spectra nist ri 959.6 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 3.3 m; Column type: Packed; Start T: 130 C; CAS no: 108861; Active phase: C78, Branched paraffin; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Reddy, K.S.; Dutoit, J.-Cl.; Kovats, E. sz., Pair-wise interactions by gas chromatography. I. Interaction free enthalpies of solutes with non-associated primary alcohol groups, J. Chromatogr., 609, 1992, 229-259.) NIST Spectra nist ri 961 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 3.7 m; Column type: Packed; Start T: 130 C; CAS no: 108861; Active phase: Apolane; Data type: Kovats RI; Authors: Dutoit, J., Gas chromatographic retention behaviour of some solutes on structurally similar polar and non-polar stationary phases, J. Chromatogr., 555, 1991, 191-204.) NIST Spectra nist ri 974 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 12 ft; Column type: Packed; Start T: 150 C; CAS no: 108861; Active phase: Apolane; Carrier gas: He; Substrate: Chromosorb G AW DCMS; Data type: Kovats RI; Authors: Evans, M.B.; Haken, J.K., Dispersion and selectivity indices of the halogenated derivatives of cyclohexane, benzene and anisole, J. Chromatogr., 389, 1987, 240-244., Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 12 ft; Column type: Packed; Start T: 150 C; CAS no: 108861; Active phase: Apolane; Substrate: Chromosorb G AW DCMS; Data type: Kovats RI; Authors: Haken, J.K.; Vernon, F., Gas chromatography of halogenated derivatives of cyclohexane, benzene and anisole, J. Chromatogr., 361, 1986, 57-61.) NIST Spectra nist ri 925.8 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 2.4 m; Column type: Packed; Start T: 70 C; CAS no: 108861; Active phase: Apolane; Carrier gas: He; Substrate: Chromosorb; Data type: Kovats RI; Authors: Riedo, F.; Fritz, D.; Tarjan, G.; Kovats, E.Sz., A tailor-made C87 hydrocarbon as a possible non-polar standard stationary phase for gas chromatography, J. Chromatogr., 126, 1976, 63-83.) NIST Spectra nist ri 961.1 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 2.4 m; Column type: Packed; Start T: 130 C; CAS no: 108861; Active phase: Apolane; Carrier gas: He; Substrate: Chromosorb; Data type: Kovats RI; Authors: Riedo, F.; Fritz, D.; Tarjan, G.; Kovats, E.Sz., A tailor-made C87 hydrocarbon as a possible non-polar standard stationary phase for gas chromatography, J. Chromatogr., 126, 1976, 63-83.) NIST Spectra nist ri 965 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 2.3 m; Column type: Packed; Start T: 100 C; CAS no: 108861; Active phase: Apiezon L; Carrier gas: N2; Substrate: DCMS-treated Chromosorb W; Data type: Kovats RI; Authors: Brown, I.; Chapman, I.L.; Nicholson, G.J., Gas chromatography of polar solutes in electron acceptor stationary phases, Aust. J. Chem., 21, 1968, 1125-1141.) NIST Spectra nist ri 982 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 2.25 m; Column type: Packed; Start T: 130 C; CAS no: 108861; Active phase: Apiezon L; Substrate: Celite; Data type: Kovats RI; Authors: Wehrli, A.; Kovats, E., Gas-chromatographische Charakterisierung ogranischer Verbindungen. Teil 3: Berechnung der Retentionsindices aliphatischer, alicyclischer und aromatischer Verbindungen, Helv. Chim. Acta, 7, 1959, 2709-2736.) NIST Spectra nist ri 1351 (Program type: Isothermal; Col… (show more) umn class: Standard polar; Column diameter: 0.25 in; Column length: 12 ft; Column type: Packed; Start T: 150 C; CAS no: 108861; Active phase: Carbowax 20M; Substrate: Chromosorb G AW DCMS; Data type: Kovats RI; Authors: Haken, J.K.; Vernon, F., Gas chromatography of halogenated derivatives of cyclohexane, benzene and anisole, J. Chromatogr., 361, 1986, 57-61.) NIST Spectra nist ri 1338 (Program type: Isothermal; Col… (show more) umn class: Standard polar; Column length: 2 m; Column type: Packed; Start T: 75 C; CAS no: 108861; Active phase: Carbowax 20M; Carrier gas: N2; Substrate: Kieselgur (60-100 mesh); Data type: Kovats RI; Authors: Goebel, K.-J., Gaschromatographische Identifizierung Niedrig Siedender Substanzen Mittels Retentionsindices und Rechnerhilfe, J. Chromatogr., 235, 1982, 119-127.) NIST Spectra nist ri -
Retention Index (Lee):
150 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 280 C; End time: 10 min; Start time: 5 min; CAS no: 108861; Active phase: HP5-MS; Carrier gas: Helium; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Vrana, B.; Paschke, H.; Paschke, A.; Popp, P.; Schuurmann, G., Performance of semipermeable membrane devices for sampling of organic contaminants in groun water, J. Envirom. Monit., 7, 2005, 500-508.) NIST Spectra nist ri -
Retention Index (Normal Alkane):
935 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Capillary; CAS no: 108861; Active phase: OV-101; Data type: Normal alkane RI; Authors: Ebrahimi, P.; Hadjmohammadi, M.R., Simultaneous modeling of the Kovats retention indices on phenyl OV stationary phases with different polarity using MLR and ANN, QSAR Comb. Sci., , 2006, 836-845.) NIST Spectra nist ri 927.2 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 40 C; End T: 260 C; Start time: 5 min; CAS no: 108861; Active phase: DB-1; Carrier gas: He; Phase thickness: 3 um; Data type: Normal alkane RI; Authors: J&W Scientific, Solvent Retention Data, 2003.) NIST Spectra nist ri 982 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Capillary; CAS no: 108861; Active phase: Methyl Silicone; Data type: Normal alkane RI; Authors: Du, X., Quantitative structure-property relationship study on analysis of retention index of organic compound in gas chromatography, Chemical World (Chinese), 42(8), 2001, 403-406.) NIST Spectra nist ri 921 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 50 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 200 C; CAS no: 108861; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.75 um; Data type: Normal alkane RI; Authors: Health Safety Executive, MDHS 96 Volatile organic compounds in air – Laboratory method using pumed solid sorbent tubes, solvent desorption and gas chromatography, in Methods for the Determination of Hazardous Substances (MDHS) guidance, Crown, Colegate, Norwich, 2000, 1-24.) NIST Spectra nist ri 921.1 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column type: Capillary; Heat rate: 4 K/min; Start T: 35 C; End T: 220 C; End time: 2 min; Start time: 10 min; CAS no: 108861; Active phase: RTX-1; Carrier gas: He; Phase thickness: 3 um; Data type: Normal alkane RI; Authors: Restek, Restek International, 1999 Product Guide, 1(1), 1999, 578-591, In original 578-591.) NIST Spectra nist ri 936 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.53 mm; Column length: 60 m; Column type: Capillary; Description: 40C(6min)=>5C/min=>80C=>10C/min=>200C; CAS no: 108861; Active phase: SPB-1; Carrier gas: He; Phase thickness: 5 um; Data type: Normal alkane RI; Authors: Flanagan, R.J.; Streete, P.J.; Ramsey, J.D., Volatile Substance Abuse, UNODC Technical Series, No 5, United Nations, Office on Drugs and Crime, Vienna International Centre, PO Box 500, A-1400 Vienna, Austria, 1997, 56.) NIST Spectra nist ri 895 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.25 mm; Column length: 55 m; Column type: Capillary; Description: 40C(3min) => 20C/min =>80C =>2C/min=>240C(45min); CAS no: 108861; Active phase: CP Sil 2; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Fuhrer, U.; Deissler, A.; Schreitmuller, J.; Ballschmiter, K., Analysis of Halogenated Methoxybenzenes and Hexachlorobenzene (HCB) in the Picogram m-3 Range in Marine Air, Chromatographia, 45, 1997, 414-427.) NIST Spectra nist ri 918.9 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 50 C; End T: 250 C; Start time: 1 min; CAS no: 108861; Active phase: HP-1; Carrier gas: He; Data type: Normal alkane RI; Authors: Katritzky, A.R.; Ignatchenko, E.S.; Barcock, R.A.; Lobanov, V.S.; Karelson, M., Prediction of gas chromatographic retention times and response factors using a general quantitative structure — property relationship treatment, Anal. Chem., 66, 1994, 1799-1807.) NIST Spectra nist ri 910 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; CAS no: 108861; Active phase: SPB-1; Data type: Normal alkane RI; Authors: Vezzani, S.; Moretti, P.; Castello, G., Fast and Accurate Method for the Automatic Prediction of Programmed-Temperature Retention Times, J. Chromatogr. A, 677, 1994, 331-343.) NIST Spectra nist ri 950.6 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 1.8 m; Column type: Packed; CAS no: 108861; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W HP; Data type: Normal alkane RI; Authors: Yurawecz, M.P.; Puma, B.J., Gas chromatographic determination of electron capture sensitive volatile industrial chemical residues in foods, using AOAC pesticide multiresidue extraction and cleanup procedures, J. Ass. Offic. Anal. Chem, 69(1), 1986, 80-86.) NIST Spectra nist ri 930 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 3.05 m; Column type: Packed; CAS no: 108861; Active phase: SE-30; Carrier gas: He; Substrate: Chromosorb AW; Data type: Normal alkane RI; Authors: Buchman, O.; Cao, G.-Y.; Peng, C.T., Structure assignment by retention index in gas-liquid radiochromatography of substituted cyclohexenes, J. Chromatogr., 312, 1984, 75-90.) NIST Spectra nist ri 945 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Capillary; CAS no: 108861; Active phase: OV-1; Data type: Normal alkane RI; Authors: Ramsey, J.D.; Flanagan, R.J., Detection and Identification of Volatile Organic Compounds in Blood by Headspace Gas Chromatography as an Aid to the Diagnosis of Solvent Abuse, J. Chromatogr., 240, 1982, 423-444.) NIST Spectra nist ri 944 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 25 m; Column type: Capillary; Start T: 100 C; CAS no: 108861; Active phase: C78, Branched paraffin; Data type: Normal alkane RI; Authors: Dallos, A.; Kresz, R.; Kovats, E., Solvation properties and limiting activity coefficients of halogenated hydrocarbons in C78H158 branched saturated alkane solvent, Fluid Phase Equilib., 210, 2003, 57-67.) NIST Spectra nist ri 983 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column length: 30 m; Column type: Capillary; CAS no: 108861; Active phase: DB-5; Carrier gas: He; Data type: Normal alkane RI; Authors: Sorimachi, J.; Tanabe, A.; Mitobe, H.; Kuniaki, K.; Masaaki, S., Programmed temperature retention indices for volatile organic compounds on headspace GC/MS analysis, Niigata-ken Eisei Kogai Kenkyusho Nenpo, 11, 1995, 75-79.) NIST Spectra nist ri 1383.1 (Program type: Ramp; Column cl… (show more) ass: Standard polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 40 C; End T: 230 C; Start time: 7 min; CAS no: 108861; Active phase: DB-Wax; Carrier gas: He; Phase thickness: 1 um; Data type: Normal alkane RI; Authors: J&W Scientific, Solvent Retention Data, 2003.) NIST Spectra nist ri 1365 (Program type: Ramp; Column cl… (show more) ass: Standard polar; Column type: Capillary; CAS no: 108861; Active phase: Carbowax 20M; Data type: Normal alkane RI; Authors: Ramsey, J.D.; Flanagan, R.J., Detection and Identification of Volatile Organic Compounds in Blood by Headspace Gas Chromatography as an Aid to the Diagnosis of Solvent Abuse, J. Chromatogr., 240, 1982, 423-444.) NIST Spectra nist ri -
Retention Index (Linear):
903.9 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 3 K/min; Start T: 40 C; End T: 325 C; CAS no: 108861; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Sun, G.; Stremple, P., Retention index characterization of flavor, fragrance, and many other compounds on DB-1 and DB-XLB, 2003.) NIST Spectra nist ri 909.5 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Capillary; Heat rate: 8 K/min; Start T: 35 C; End T: 300 C; CAS no: 108861; Active phase: OV-1; Data type: Linear RI; Authors: Gautzsch, R.; Zinn, P., Use of incremental models to estimate the retention indexes of aromatic compounds, Chromatographia, 43(3/4), 1996, 163-176.) NIST Spectra nist ri 915 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.235 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; Start time: 0 min; CAS no: 108861; Active phase: DB-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Gerbino, T.C.; Castello, G., Prediction of programmed temperature retention indices on capillary columns of different polarities, J. Chromatogr. A, 699, 1995, 161-171.) NIST Spectra nist ri 918 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.235 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 50 C; Start time: 0 min; CAS no: 108861; Active phase: DB-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Gerbino, T.C.; Castello, G., Prediction of programmed temperature retention indices on capillary columns of different polarities, J. Chromatogr. A, 699, 1995, 161-171.) NIST Spectra nist ri 927 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.235 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 100 C; Start time: 0 min; CAS no: 108861; Active phase: DB-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Gerbino, T.C.; Castello, G., Prediction of programmed temperature retention indices on capillary columns of different polarities, J. Chromatogr. A, 699, 1995, 161-171., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.235 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 100 C; Start time: 0 min; CAS no: 108861; Active phase: DB-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Gerbino, T.C.; Castello, G., Prediction of programmed temperature retention indices on capillary columns of different polarities, J. Chromatogr. A, 699, 1995, 161-171.) NIST Spectra nist ri 930 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 3.05 m; Column type: Packed; Heat rate: 10 K/min; Start T: 40 C; End T: 210 C; End time: 30 min; Start time: 10 min; CAS no: 108861; Active phase: SE-30; Carrier gas: He; Substrate: Chromosorb AW; Data type: Linear RI; Authors: Buchman, O.; Cao, G.-Y.; Peng, C.T., Structure assignment by retention index in gas-liquid radiochromatography of substituted cyclohexenes, J. Chromatogr., 312, 1984, 75-90.) NIST Spectra nist ri 941 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 60 m; Column type: Capillary; Heat rate: 3 K/min; Start T: 40 C; End T: 230 C; End time: 10 min; Start time: 2 min; CAS no: 108861; Active phase: SPB-5; Phase thickness: 1 um; Data type: Linear RI; Authors: Engel, E.; Ratel, J., Correction of the data generated by mass spectrometry analyses of biological tissues: Application to food authentication, J. Chromatogr. A, 1154, 2007, 331-341.) NIST Spectra nist ri 926 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 50 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 60 C; End T: 220 C; End time: 30 min; Start time: 5 min; CAS no: 108861; Active phase: CP Sil 8 CB; Data type: Linear RI; Authors: Chevance, F.F.V.; Farmer, L.J., Identification of major volatile odor compounds in frankfurters, J. Agric. Food Chem., 47, 1999, 5151-5160.) NIST Spectra nist ri 919.67 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 50 C; CAS no: 108861; Active phase: DB-5; Carrier gas: N2; Phase thickness: 1.5 um; Data type: Linear RI; Authors: Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 86, 1996, 63-75.) NIST Spectra nist ri 921.35 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 50 C; CAS no: 108861; Active phase: DB-5; Carrier gas: N2; Phase thickness: 1.5 um; Data type: Linear RI; Authors: Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 86, 1996, 63-75.) NIST Spectra nist ri 926.64 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 50 C; CAS no: 108861; Active phase: DB-5; Carrier gas: N2; Phase thickness: 1.5 um; Data type: Linear RI; Authors: Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 86, 1996, 63-75.) NIST Spectra nist ri 1330 (Program type: Ramp; Column cl… (show more) ass: Standard polar; Column diameter: 0.32 mm; Column length: 50 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 60 C; End T: 220 C; End time: 30 min; Start time: 5 min; CAS no: 108861; Active phase: CP-Wax 52CB; Data type: Linear RI; Authors: Chevance, F.F.V.; Farmer, L.J., Identification of major volatile odor compounds in frankfurters, J. Agric. Food Chem., 47, 1999, 5151-5160.) NIST Spectra nist ri 1348.92 (Program type: Ramp; Column cl… (show more) ass: Standard polar; Column diameter: 0.235 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; CAS no: 108861; Active phase: DB-Wax; Carrier gas: N2; Phase thickness: 0.5 um; Data type: Linear RI; Authors: Gerbino, T.C.; Castello, G., Prediction of programmed temperature retention indices on capillary columns of different polarities, J. Chromatogr. A, 699, 1995, 161-171.) NIST Spectra nist ri 1358.59 (Program type: Ramp; Column cl… (show more) <span id="ID0EADABA" class="truncatedanno Haven't found what you were looking for?
Search for samples, answers to your questions and flashcards
Get an explanation on any taskGet unstuck with the help of our AI assistant in secondsNewHaven't found what you were looking for?
-