Molecular Formula C6H5Br
Average mass 157.008 Da
Density 1.5±0.1 g/cm3
Boiling Point 154.2±9.0 °C at 760 mmHg
Flash Point 51.1±0.0 °C
Molar Refractivity 33.9±0.3 cm3
Polarizability 13.5±0.5 10-24cm3
Surface Tension 35.5±3.0 dyne/cm
Molar Volume 105.6±3.0 cm3
  • Experimental data
  • Predicted – ACD/Labs
  • Predicted – EPISuite
  • Predicted – ChemAxon
  • Predicted – Mcule
  • Experimental Physico-chemical Properties
    • Experimental Melting Point:

      -31 °C Alfa Aesar
      -30.6 °C Jean-Claude Bradley Open Melting Point Dataset 20491
      -31 °C Jean-Claude Bradley Open Melting Point Dataset 14025, 15630, 6576
      -31 °C Alfa Aesar A11407
      -31 °C SynQuest 1600-9-01
      -31 °C Oakwood BR1026
      -31 °C LabNetwork LN00194621
    • Experimental Boiling Point:

      155-156 °C Alfa Aesar
      155-156 °C Alfa Aesar A11407
      155-156 °C SynQuest 1600-9-01
      156 °C Oakwood BR1026
      156 °C LabNetwork LN00194621
    • Experimental Flash Point:

      51 °C Alfa Aesar
      51 °C Alfa Aesar
      51 °F (10.5556 °C)
      Alfa Aesar A11407
      51 °C SynQuest 1600-9-01
      51 °C Oakwood BR1026
      51 °C LabNetwork LN00194621
    • Experimental Gravity:

      1.494-1.496 g/mL / 20 °C Merck Millipore 801786
      20 g/mL Merck Millipore 1299
      20 g/l Merck Millipore 1299, 801786
      1.492 g/mL Alfa Aesar A11407
      1.492 g/mL SynQuest 1600-9-01
      1.491 g/mL Oakwood BR1026
    • Experimental Refraction Index:

      1.559 SynQuest 1600-9-01
  • Miscellaneous
    • Safety:

      10-38-51/53 Alfa Aesar A11407
      3 Alfa Aesar A11407
      61 Alfa Aesar A11407
      DANGER: FLAMMABLE, irritates skin, eyes, lungs Alfa Aesar A11407
      Flammable/Irritant SynQuest 1600-9-01
      H226-H315-H411 Alfa Aesar A11407
      P210-P280-P303+P361+P353-P362-P403+P235-P501a Alfa Aesar A11407
      Warning Alfa Aesar A11407
  • Gas Chromatography
    • Retention Index (Kovats):

      1000 (estimated with error: 62) NIST Spectra mainlib_291408, replib_5387, replib_190208, replib_227767, replib_379207
      914.7 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 5 m; Column type: Packed; Start T: 80 C; CAS no: 108861; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Righezza, M.; Hassani, A.; Meklati, B.Y.; Chretien, J.R., Quantitative structure-retention relationships (QSRR) of congeneric aromatics series studied on phenyl OV phases in gas chromatography, J. Chromatogr. A, 723, 1996, 77-91.) NIST Spectra nist ri
      923.7 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 5 m; Column type: Packed; Start T: 90 C; CAS no: 108861; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Righezza, M.; Hassani, A.; Meklati, B.Y.; Chretien, J.R., Quantitative structure-retention relationships (QSRR) of congeneric aromatics series studied on phenyl OV phases in gas chromatography, J. Chromatogr. A, 723, 1996, 77-91.) NIST Spectra nist ri
      924 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 5 m; Column type: Packed; Start T: 100 C; CAS no: 108861; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Righezza, M.; Hassani, A.; Meklati, B.Y.; Chretien, J.R., Quantitative structure-retention relationships (QSRR) of congeneric aromatics series studied on phenyl OV phases in gas chromatography, J. Chromatogr. A, 723, 1996, 77-91.) NIST Spectra nist ri
      932 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 5 m; Column type: Packed; Start T: 110 C; CAS no: 108861; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Righezza, M.; Hassani, A.; Meklati, B.Y.; Chretien, J.R., Quantitative structure-retention relationships (QSRR) of congeneric aromatics series studied on phenyl OV phases in gas chromatography, J. Chromatogr. A, 723, 1996, 77-91.) NIST Spectra nist ri
      934.8 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 5 m; Column type: Packed; Start T: 120 C; CAS no: 108861; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Hassani, A.; Meklati, B.Y., Gas chromatographic behaviour of monosubstituted benzenes, benzaldehydes and acetophenones on OV polymethylphenyl-silicone stationary phases, Chromatographia, 33(5/6), 1992, 267-271.) NIST Spectra nist ri
      964 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 3 m; Column type: Packed; Start T: 180 C; CAS no: 108861; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb A AW; Data type: Kovats RI; Authors: Oszczapowicz, J.; Osek, J.; Ciszkowski, K.; Krawczyk, W.; Ostrowski, M., Retention Indices of Dimethylbenzamidines and Benzylideneamines on a Non-Polar Column, J. Chromatogr., 330, 1985, 79-85., Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 3 m; Column type: Packed; Start T: 180 C; CAS no: 108861; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W AW; Data type: Kovats RI; Authors: Oszczapowicz, J.; Osek, J.; Dolecka, E., Retention indices of dimethylformamidines, dimethylacetamidines and tetramethylguanidines on a non-polar column, J. Chromatogr., 315, 1984, 95-100.) NIST Spectra nist ri
      945 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 3 m; Column type: Packed; Start T: 150 C; CAS no: 108861; Active phase: SE-30; Carrier gas: Ar; Substrate: Gas Chrom Q (80-100 mesh); Data type: Kovats RI; Authors: Tiess, D., Gaschromatographische Retentionsindices von 125 leicht- bis mittelfluchtigen organischen Substanzen toxikologisch-analytischer Relevanz auf SE-30, Wiss. Z. Wilhelm-Pieck-Univ. Rostock Math. Naturwiss. Reihe, 33, 1984, 6-9.) NIST Spectra nist ri
      960 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 3.3 m; Column type: Packed; Start T: 130 C; CAS no: 108861; Active phase: C78, Branched paraffin; Carrier gas: He; Data type: Kovats RI; Authors: Dallos, A.; Sisak, A.; Kulcsar, Z.; Kovats, E., Pair-wise interactions by gas chromatography VII. Interaction free enthalpies of solutes with secondary alcohol groups, J. Chromatogr. A, 904, 2000, 211-242.) NIST Spectra nist ri
      931.71 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Start T: 70 C; CAS no: 108861; Active phase: DB-5; Carrier gas: N2; Phase thickness: 1.5 um; Data type: Kovats RI; Authors: Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 86, 1996, 63-75.) NIST Spectra nist ri
      941.36 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Start T: 90 C; CAS no: 108861; Active phase: DB-5; Carrier gas: N2; Phase thickness: 1.5 um; Data type: Kovats RI; Authors: Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 86, 1996, 63-75.) NIST Spectra nist ri
      952.2 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Start T: 110 C; CAS no: 108861; Active phase: DB-5; Carrier gas: N2; Phase thickness: 1.5 um; Data type: Kovats RI; Authors: Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 86, 1996, 63-75.) NIST Spectra nist ri
      979.6 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 2 m; Column type: Packed; CAS no: 108861; Active phase: Apiezon M; Substrate: Chromosorb W; Data type: Kovats RI; Authors: Jalali-Heravi, M.; Garkani-Nejad, Z., Prediction of gas chromatographic retention indices of some benzene derivatives, J. Chromatogr., 648, 1993, 389-393.) NIST Spectra nist ri
      973.7 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 5 m; Column type: Packed; Start T: 120 C; CAS no: 108861; Active phase: OV-3; Carrier gas: N2; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Hassani, A.; Meklati, B.Y., Gas chromatographic behaviour of monosubstituted benzenes, benzaldehydes and acetophenones on OV polymethylphenyl-silicone stationary phases, Chromatographia, 33(5/6), 1992, 267-271.) NIST Spectra nist ri
      959.6 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 3.3 m; Column type: Packed; Start T: 130 C; CAS no: 108861; Active phase: C78, Branched paraffin; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Reddy, K.S.; Dutoit, J.-Cl.; Kovats, E. sz., Pair-wise interactions by gas chromatography. I. Interaction free enthalpies of solutes with non-associated primary alcohol groups, J. Chromatogr., 609, 1992, 229-259.) NIST Spectra nist ri
      961 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 3.7 m; Column type: Packed; Start T: 130 C; CAS no: 108861; Active phase: Apolane; Data type: Kovats RI; Authors: Dutoit, J., Gas chromatographic retention behaviour of some solutes on structurally similar polar and non-polar stationary phases, J. Chromatogr., 555, 1991, 191-204.) NIST Spectra nist ri
      974 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 12 ft; Column type: Packed; Start T: 150 C; CAS no: 108861; Active phase: Apolane; Carrier gas: He; Substrate: Chromosorb G AW DCMS; Data type: Kovats RI; Authors: Evans, M.B.; Haken, J.K., Dispersion and selectivity indices of the halogenated derivatives of cyclohexane, benzene and anisole, J. Chromatogr., 389, 1987, 240-244., Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 12 ft; Column type: Packed; Start T: 150 C; CAS no: 108861; Active phase: Apolane; Substrate: Chromosorb G AW DCMS; Data type: Kovats RI; Authors: Haken, J.K.; Vernon, F., Gas chromatography of halogenated derivatives of cyclohexane, benzene and anisole, J. Chromatogr., 361, 1986, 57-61.) NIST Spectra nist ri
      925.8 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 2.4 m; Column type: Packed; Start T: 70 C; CAS no: 108861; Active phase: Apolane; Carrier gas: He; Substrate: Chromosorb; Data type: Kovats RI; Authors: Riedo, F.; Fritz, D.; Tarjan, G.; Kovats, E.Sz., A tailor-made C87 hydrocarbon as a possible non-polar standard stationary phase for gas chromatography, J. Chromatogr., 126, 1976, 63-83.) NIST Spectra nist ri
      961.1 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 2.4 m; Column type: Packed; Start T: 130 C; CAS no: 108861; Active phase: Apolane; Carrier gas: He; Substrate: Chromosorb; Data type: Kovats RI; Authors: Riedo, F.; Fritz, D.; Tarjan, G.; Kovats, E.Sz., A tailor-made C87 hydrocarbon as a possible non-polar standard stationary phase for gas chromatography, J. Chromatogr., 126, 1976, 63-83.) NIST Spectra nist ri
      965 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 2.3 m; Column type: Packed; Start T: 100 C; CAS no: 108861; Active phase: Apiezon L; Carrier gas: N2; Substrate: DCMS-treated Chromosorb W; Data type: Kovats RI; Authors: Brown, I.; Chapman, I.L.; Nicholson, G.J., Gas chromatography of polar solutes in electron acceptor stationary phases, Aust. J. Chem., 21, 1968, 1125-1141.) NIST Spectra nist ri
      982 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 2.25 m; Column type: Packed; Start T: 130 C; CAS no: 108861; Active phase: Apiezon L; Substrate: Celite; Data type: Kovats RI; Authors: Wehrli, A.; Kovats, E., Gas-chromatographische Charakterisierung ogranischer Verbindungen. Teil 3: Berechnung der Retentionsindices aliphatischer, alicyclischer und aromatischer Verbindungen, Helv. Chim. Acta, 7, 1959, 2709-2736.) NIST Spectra nist ri
      1351 (Program type: Isothermal; Col… (show more) umn class: Standard polar; Column diameter: 0.25 in; Column length: 12 ft; Column type: Packed; Start T: 150 C; CAS no: 108861; Active phase: Carbowax 20M; Substrate: Chromosorb G AW DCMS; Data type: Kovats RI; Authors: Haken, J.K.; Vernon, F., Gas chromatography of halogenated derivatives of cyclohexane, benzene and anisole, J. Chromatogr., 361, 1986, 57-61.) NIST Spectra nist ri
      1338 (Program type: Isothermal; Col… (show more) umn class: Standard polar; Column length: 2 m; Column type: Packed; Start T: 75 C; CAS no: 108861; Active phase: Carbowax 20M; Carrier gas: N2; Substrate: Kieselgur (60-100 mesh); Data type: Kovats RI; Authors: Goebel, K.-J., Gaschromatographische Identifizierung Niedrig Siedender Substanzen Mittels Retentionsindices und Rechnerhilfe, J. Chromatogr., 235, 1982, 119-127.) NIST Spectra nist ri
    • Retention Index (Lee):

      150 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 280 C; End time: 10 min; Start time: 5 min; CAS no: 108861; Active phase: HP5-MS; Carrier gas: Helium; Phase thickness: 0.25 um; Data type: Lee RI; Authors: Vrana, B.; Paschke, H.; Paschke, A.; Popp, P.; Schuurmann, G., Performance of semipermeable membrane devices for sampling of organic contaminants in groun water, J. Envirom. Monit., 7, 2005, 500-508.) NIST Spectra nist ri
    • Retention Index (Normal Alkane):

      935 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Capillary; CAS no: 108861; Active phase: OV-101; Data type: Normal alkane RI; Authors: Ebrahimi, P.; Hadjmohammadi, M.R., Simultaneous modeling of the Kovats retention indices on phenyl OV stationary phases with different polarity using MLR and ANN, QSAR Comb. Sci., , 2006, 836-845.) NIST Spectra nist ri
      927.2 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 40 C; End T: 260 C; Start time: 5 min; CAS no: 108861; Active phase: DB-1; Carrier gas: He; Phase thickness: 3 um; Data type: Normal alkane RI; Authors: J&W Scientific, Solvent Retention Data, 2003.) NIST Spectra nist ri
      982 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Capillary; CAS no: 108861; Active phase: Methyl Silicone; Data type: Normal alkane RI; Authors: Du, X., Quantitative structure-property relationship study on analysis of retention index of organic compound in gas chromatography, Chemical World (Chinese), 42(8), 2001, 403-406.) NIST Spectra nist ri
      921 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 50 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 200 C; CAS no: 108861; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.75 um; Data type: Normal alkane RI; Authors: Health Safety Executive, MDHS 96 Volatile organic compounds in air – Laboratory method using pumed solid sorbent tubes, solvent desorption and gas chromatography, in Methods for the Determination of Hazardous Substances (MDHS) guidance, Crown, Colegate, Norwich, 2000, 1-24.) NIST Spectra nist ri
      921.1 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column type: Capillary; Heat rate: 4 K/min; Start T: 35 C; End T: 220 C; End time: 2 min; Start time: 10 min; CAS no: 108861; Active phase: RTX-1; Carrier gas: He; Phase thickness: 3 um; Data type: Normal alkane RI; Authors: Restek, Restek International, 1999 Product Guide, 1(1), 1999, 578-591, In original 578-591.) NIST Spectra nist ri
      936 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.53 mm; Column length: 60 m; Column type: Capillary; Description: 40C(6min)=>5C/min=>80C=>10C/min=>200C; CAS no: 108861; Active phase: SPB-1; Carrier gas: He; Phase thickness: 5 um; Data type: Normal alkane RI; Authors: Flanagan, R.J.; Streete, P.J.; Ramsey, J.D., Volatile Substance Abuse, UNODC Technical Series, No 5, United Nations, Office on Drugs and Crime, Vienna International Centre, PO Box 500, A-1400 Vienna, Austria, 1997, 56.) NIST Spectra nist ri
      895 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.25 mm; Column length: 55 m; Column type: Capillary; Description: 40C(3min) => 20C/min =>80C =>2C/min=>240C(45min); CAS no: 108861; Active phase: CP Sil 2; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Fuhrer, U.; Deissler, A.; Schreitmuller, J.; Ballschmiter, K., Analysis of Halogenated Methoxybenzenes and Hexachlorobenzene (HCB) in the Picogram m-3 Range in Marine Air, Chromatographia, 45, 1997, 414-427.) NIST Spectra nist ri
      918.9 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 50 C; End T: 250 C; Start time: 1 min; CAS no: 108861; Active phase: HP-1; Carrier gas: He; Data type: Normal alkane RI; Authors: Katritzky, A.R.; Ignatchenko, E.S.; Barcock, R.A.; Lobanov, V.S.; Karelson, M., Prediction of gas chromatographic retention times and response factors using a general quantitative structure — property relationship treatment, Anal. Chem., 66, 1994, 1799-1807.) NIST Spectra nist ri
      910 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; CAS no: 108861; Active phase: SPB-1; Data type: Normal alkane RI; Authors: Vezzani, S.; Moretti, P.; Castello, G., Fast and Accurate Method for the Automatic Prediction of Programmed-Temperature Retention Times, J. Chromatogr. A, 677, 1994, 331-343.) NIST Spectra nist ri
      950.6 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 1.8 m; Column type: Packed; CAS no: 108861; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W HP; Data type: Normal alkane RI; Authors: Yurawecz, M.P.; Puma, B.J., Gas chromatographic determination of electron capture sensitive volatile industrial chemical residues in foods, using AOAC pesticide multiresidue extraction and cleanup procedures, J. Ass. Offic. Anal. Chem, 69(1), 1986, 80-86.) NIST Spectra nist ri
      930 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 3.05 m; Column type: Packed; CAS no: 108861; Active phase: SE-30; Carrier gas: He; Substrate: Chromosorb AW; Data type: Normal alkane RI; Authors: Buchman, O.; Cao, G.-Y.; Peng, C.T., Structure assignment by retention index in gas-liquid radiochromatography of substituted cyclohexenes, J. Chromatogr., 312, 1984, 75-90.) NIST Spectra nist ri
      945 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Capillary; CAS no: 108861; Active phase: OV-1; Data type: Normal alkane RI; Authors: Ramsey, J.D.; Flanagan, R.J., Detection and Identification of Volatile Organic Compounds in Blood by Headspace Gas Chromatography as an Aid to the Diagnosis of Solvent Abuse, J. Chromatogr., 240, 1982, 423-444.) NIST Spectra nist ri
      944 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 25 m; Column type: Capillary; Start T: 100 C; CAS no: 108861; Active phase: C78, Branched paraffin; Data type: Normal alkane RI; Authors: Dallos, A.; Kresz, R.; Kovats, E., Solvation properties and limiting activity coefficients of halogenated hydrocarbons in C78H158 branched saturated alkane solvent, Fluid Phase Equilib., 210, 2003, 57-67.) NIST Spectra nist ri
      983 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column length: 30 m; Column type: Capillary; CAS no: 108861; Active phase: DB-5; Carrier gas: He; Data type: Normal alkane RI; Authors: Sorimachi, J.; Tanabe, A.; Mitobe, H.; Kuniaki, K.; Masaaki, S., Programmed temperature retention indices for volatile organic compounds on headspace GC/MS analysis, Niigata-ken Eisei Kogai Kenkyusho Nenpo, 11, 1995, 75-79.) NIST Spectra nist ri
      1383.1 (Program type: Ramp; Column cl… (show more) ass: Standard polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 40 C; End T: 230 C; Start time: 7 min; CAS no: 108861; Active phase: DB-Wax; Carrier gas: He; Phase thickness: 1 um; Data type: Normal alkane RI; Authors: J&W Scientific, Solvent Retention Data, 2003.) NIST Spectra nist ri
      1365 (Program type: Ramp; Column cl… (show more) ass: Standard polar; Column type: Capillary; CAS no: 108861; Active phase: Carbowax 20M; Data type: Normal alkane RI; Authors: Ramsey, J.D.; Flanagan, R.J., Detection and Identification of Volatile Organic Compounds in Blood by Headspace Gas Chromatography as an Aid to the Diagnosis of Solvent Abuse, J. Chromatogr., 240, 1982, 423-444.) NIST Spectra nist ri
    • Retention Index (Linear):

      903.9 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 3 K/min; Start T: 40 C; End T: 325 C; CAS no: 108861; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Sun, G.; Stremple, P., Retention index characterization of flavor, fragrance, and many other compounds on DB-1 and DB-XLB, 2003.) NIST Spectra nist ri
      909.5 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Capillary; Heat rate: 8 K/min; Start T: 35 C; End T: 300 C; CAS no: 108861; Active phase: OV-1; Data type: Linear RI; Authors: Gautzsch, R.; Zinn, P., Use of incremental models to estimate the retention indexes of aromatic compounds, Chromatographia, 43(3/4), 1996, 163-176.) NIST Spectra nist ri
      915 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.235 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; Start time: 0 min; CAS no: 108861; Active phase: DB-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Gerbino, T.C.; Castello, G., Prediction of programmed temperature retention indices on capillary columns of different polarities, J. Chromatogr. A, 699, 1995, 161-171.) NIST Spectra nist ri
      918 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.235 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 50 C; Start time: 0 min; CAS no: 108861; Active phase: DB-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Gerbino, T.C.; Castello, G., Prediction of programmed temperature retention indices on capillary columns of different polarities, J. Chromatogr. A, 699, 1995, 161-171.) NIST Spectra nist ri
      927 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.235 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 100 C; Start time: 0 min; CAS no: 108861; Active phase: DB-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Gerbino, T.C.; Castello, G., Prediction of programmed temperature retention indices on capillary columns of different polarities, J. Chromatogr. A, 699, 1995, 161-171., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.235 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 100 C; Start time: 0 min; CAS no: 108861; Active phase: DB-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Gerbino, T.C.; Castello, G., Prediction of programmed temperature retention indices on capillary columns of different polarities, J. Chromatogr. A, 699, 1995, 161-171.) NIST Spectra nist ri
      930 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 3.05 m; Column type: Packed; Heat rate: 10 K/min; Start T: 40 C; End T: 210 C; End time: 30 min; Start time: 10 min; CAS no: 108861; Active phase: SE-30; Carrier gas: He; Substrate: Chromosorb AW; Data type: Linear RI; Authors: Buchman, O.; Cao, G.-Y.; Peng, C.T., Structure assignment by retention index in gas-liquid radiochromatography of substituted cyclohexenes, J. Chromatogr., 312, 1984, 75-90.) NIST Spectra nist ri
      941 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 60 m; Column type: Capillary; Heat rate: 3 K/min; Start T: 40 C; End T: 230 C; End time: 10 min; Start time: 2 min; CAS no: 108861; Active phase: SPB-5; Phase thickness: 1 um; Data type: Linear RI; Authors: Engel, E.; Ratel, J., Correction of the data generated by mass spectrometry analyses of biological tissues: Application to food authentication, J. Chromatogr. A, 1154, 2007, 331-341.) NIST Spectra nist ri
      926 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 50 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 60 C; End T: 220 C; End time: 30 min; Start time: 5 min; CAS no: 108861; Active phase: CP Sil 8 CB; Data type: Linear RI; Authors: Chevance, F.F.V.; Farmer, L.J., Identification of major volatile odor compounds in frankfurters, J. Agric. Food Chem., 47, 1999, 5151-5160.) NIST Spectra nist ri
      919.67 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 50 C; CAS no: 108861; Active phase: DB-5; Carrier gas: N2; Phase thickness: 1.5 um; Data type: Linear RI; Authors: Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 86, 1996, 63-75.) NIST Spectra nist ri
      921.35 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 50 C; CAS no: 108861; Active phase: DB-5; Carrier gas: N2; Phase thickness: 1.5 um; Data type: Linear RI; Authors: Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 86, 1996, 63-75.) NIST Spectra nist ri
      926.64 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 50 C; CAS no: 108861; Active phase: DB-5; Carrier gas: N2; Phase thickness: 1.5 um; Data type: Linear RI; Authors: Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 86, 1996, 63-75.) NIST Spectra nist ri
      1330 (Program type: Ramp; Column cl… (show more) ass: Standard polar; Column diameter: 0.32 mm; Column length: 50 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 60 C; End T: 220 C; End time: 30 min; Start time: 5 min; CAS no: 108861; Active phase: CP-Wax 52CB; Data type: Linear RI; Authors: Chevance, F.F.V.; Farmer, L.J., Identification of major volatile odor compounds in frankfurters, J. Agric. Food Chem., 47, 1999, 5151-5160.) NIST Spectra nist ri
      1348.92 (Program type: Ramp; Column cl… (show more) ass: Standard polar; Column diameter: 0.235 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; CAS no: 108861; Active phase: DB-Wax; Carrier gas: N2; Phase thickness: 0.5 um; Data type: Linear RI; Authors: Gerbino, T.C.; Castello, G., Prediction of programmed temperature retention indices on capillary columns of different polarities, J. Chromatogr. A, 699, 1995, 161-171.) NIST Spectra nist ri
      1358.59 (Program type: Ramp; Column cl… (show more) <span id="ID0EADABA" class="truncatedanno