Methyl acetate C3H6O2 structure – Flashcards
Flashcard maker : Daniel Thompson
Contents
- Experimental Melting Point:
- Experimental Boiling Point:
- Experimental Ionization Potent:
- Experimental Vapor Pressure:
- Experimental LogP:
- Experimental Flash Point:
- Experimental Freezing Point:
- Experimental Gravity:
- Experimental Refraction Index:
- Experimental Solubility:
- Appearance:
- Stability:
- Toxicity:
- Safety:
- First-Aid:
- Exposure Routes:
- Symptoms:
- Target Organs:
- Incompatibility:
- Personal Protection:
- Exposure Limits:
- Retention Index (Kovats):
Molecular Formula | C3H6O2 |
Average mass | 74.078 Da |
Density | 0.9±0.1 g/cm3 |
Boiling Point | 44.0±3.0 °C at 760 mmHg |
Flash Point | -9.4±0.0 °C |
Molar Refractivity | 17.7±0.3 cm3 |
Polarizability | 7.0±0.5 10-24cm3 |
Surface Tension | 21.8±3.0 dyne/cm |
Molar Volume | 81.5±3.0 cm3 |
- Experimental data
- Predicted – ACD/Labs
- Predicted – EPISuite
- Predicted – ChemAxon
- Predicted – Mcule
- Experimental Physico-chemical Properties
-
Experimental Melting Point:
-98 °C Oxford University Chemical Safety Data (No longer updated) More details -98 °C Jean-Claude Bradley Open Melting Point Dataset 13164, 15905, 21165, 7641 -98 °C Alfa Aesar L14475 -98 °C LabNetwork LN00163448 -98 °C Indofine
[025434S]-98.7 °C FooDB FDB008125 -
Experimental Boiling Point:
135 F (57.2222 °C)
NIOSH AI910000056.9-57.5 °C Food and Agriculture Organization of the United Nations Methyl acetate 56 °C Oxford University Chemical Safety Data (No longer updated) More details 56-58 °C Alfa Aesar L14475 57-58 °C LabNetwork LN00163448 56.3 °C FooDB FDB008125 -
Experimental Ionization Potent:
10.27 Ev NIOSH AI9100000 -
Experimental Vapor Pressure:
173 mmHg NIOSH AI9100000 -
Experimental LogP:
0.18 Egon Willighagen http://dx.doi.org/10.1021/ci050282s -
Experimental Flash Point:
14 F (-10 °C)
NIOSH AI9100000-10 °C Oxford University Chemical Safety Data (No longer updated) More details -10 °C Alfa Aesar -10 °F (-23.3333 °C)
Alfa Aesar L14475-10 °C LabNetwork LN00163448 -
Experimental Freezing Point:
-145 F (-98.3333 °C)
NIOSH AI9100000 -
Experimental Gravity:
20 g/mL Merck Millipore 1814 20 g/l Merck Millipore 1814, 809711 0.934 g/mL Alfa Aesar L14475 -
Experimental Refraction Index:
1.362 Alfa Aesar L14475 1.358-1.363 Food and Agriculture Organization of the United Nations Methyl acetate 20 FooDB FDB008125 -
Experimental Solubility:
25% NIOSH AI9100000
-
- Miscellaneous
-
Appearance:
Colorless liquid with a fragrant, fruity odor. NIOSH AI9100000 colourless liquid with a pleasant odour Oxford University Chemical Safety Data (No longer updated) More details colourless liquid with a pleasant, fruity odour Food and Agriculture Organization of the United Nations Methyl acetate -
Stability:
Stable. Extremely flammable – readily forms explosive mixtureswith air. Note low flash point and wide explosion limits. Incompatible with strong oxidizing agents, strong bases, strong acids, nitrates
.May be moisture sensitive. Oxford University Chemical Safety Data (No longer updated) More details -
Toxicity:
ORL-RAT LD50 6970 mg kg-1, ORL-RBT LD50 3705 mg kg-1 Oxford University Chemical Safety Data (No longer updated) More details -
Safety:
11-36-66-67 Alfa Aesar L14475 16-26-29-33 Alfa Aesar L14475 3 Alfa Aesar L14475 Danger Alfa Aesar L14475 FLAMMABLE / IRRITANT Alfa Aesar L14475 H225-H319-H336-EUH066 Alfa Aesar L14475 P210-P261-P303+P361+P353-P305+P351+P338-P405-P501a Alfa Aesar L14475 Safety glasses, good ventilation. Remove sources ofignition from the working area. Oxford University Chemical Safety Data (No longer updated) More details -
First-Aid:
Eye: Irrigate immediately Skin: Water flush promptly Breathing: Respiratory support Swallow: Medical attention immediately NIOSH AI9100000 -
Exposure Routes:
inhalation, ingestion, skin and/or eye contact NIOSH AI9100000 -
Symptoms:
Irritation eyes, skin, nose, throat; headache, drowsiness; optic nerve atrophy; chest tightness; in animals: narcosis NIOSH AI9100000 -
Target Organs:
Eyes, skin, respiratory system, central nervous system NIOSH AI9100000 -
Incompatibility:
Nitrates; strong oxidizers, alkalis & acids; water [Note: Reacts slowly with water to form acetic acid & methanol.] NIOSH AI9100000 -
Personal Protection:
Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet (flammable) Change: No recommendation NIOSH AI9100000 -
Exposure Limits:
NIOSH REL : TWA 200 ppm (610 mg/m 3 ) ST 250 ppm (760 mg/m 3 ) OSHA PEL ?: TWA 200 ppm (610 mg/m 3 ) NIOSH AI9100000
-
- Gas Chromatography
-
Retention Index (Kovats):
487 (estimated with error: 47) NIST Spectra mainlib_291292, replib_229449, replib_154747 501.15 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.256 mm; Column length: 30 m; Column type: Capillary; Start T: 80 C; CAS no: 79209; Active phase: DB-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Mijin, D.; Antonovic, D.G., The temperature dependence of the retention index for n-alkyl esters of acetic, propionic, cyclohexanecarboxylic, benzoic and phenylacetic acid on DB-1 and DB-5 capillary columns, J. Serb. Chem. Soc., 71(6), 2006, 629-637.) NIST Spectra nist ri 511.5 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Start T: 60 C; CAS no: 79209; Active phase: HP-1; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Wang, Y.; Liu, J.; Li, N.; Shi, G.; Jiang, G.; Ma, W., Preliminary study of the retention behavior for different compounds using cryogenic chromatography at different initial temperatures, Microchem. J., 81, 2005, 184-190.) NIST Spectra nist ri 513.8 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Start T: 50 C; CAS no: 79209; Active phase: HP-1; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Wang, Y.; Liu, J.; Li, N.; Shi, G.; Jiang, G.; Ma, W., Preliminary study of the retention behavior for different compounds using cryogenic chromatography at different initial temperatures, Microchem. J., 81, 2005, 184-190.) NIST Spectra nist ri 515.7 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Start T: 40 C; CAS no: 79209; Active phase: HP-1; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Wang, Y.; Liu, J.; Li, N.; Shi, G.; Jiang, G.; Ma, W., Preliminary study of the retention behavior for different compounds using cryogenic chromatography at different initial temperatures, Microchem. J., 81, 2005, 184-190.) NIST Spectra nist ri 520.6 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Start T: 0 C; CAS no: 79209; Active phase: HP-1; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Wang, Y.; Liu, J.; Li, N.; Shi, G.; Jiang, G.; Ma, W., Preliminary study of the retention behavior for different compounds using cryogenic chromatography at different initial temperatures, Microchem. J., 81, 2005, 184-190.) NIST Spectra nist ri 521 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Start T: 10 C; CAS no: 79209; Active phase: HP-1; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Wang, Y.; Liu, J.; Li, N.; Shi, G.; Jiang, G.; Ma, W., Preliminary study of the retention behavior for different compounds using cryogenic chromatography at different initial temperatures, Microchem. J., 81, 2005, 184-190.) NIST Spectra nist ri 521.3 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Start T: 30 C; CAS no: 79209; Active phase: HP-1; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Wang, Y.; Liu, J.; Li, N.; Shi, G.; Jiang, G.; Ma, W., Preliminary study of the retention behavior for different compounds using cryogenic chromatography at different initial temperatures, Microchem. J., 81, 2005, 184-190.) NIST Spectra nist ri 526.2 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Start T: 20 C; CAS no: 79209; Active phase: HP-1; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Wang, Y.; Liu, J.; Li, N.; Shi, G.; Jiang, G.; Ma, W., Preliminary study of the retention behavior for different compounds using cryogenic chromatography at different initial temperatures, Microchem. J., 81, 2005, 184-190.) NIST Spectra nist ri 505 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.33 mm; Column length: 25 m; Column type: Capillary; Start T: 100 C; CAS no: 79209; Active phase: SE-30; Carrier gas: N2; Data type: Kovats RI; Authors: Haken, J.K.; Korhonen, I.O.O., Gas chromatography of homologous esters. XXXII. Capillary chromatography of C1-C18 monochlorinated n-alkyl acetates, J. Chromatogr., 356, 1986, 79-94., Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.33 mm; Column length: 25 m; Column type: Capillary; Start T: 80 C; CAS no: 79209; Active phase: SE-30; Carrier gas: N2; Data type: Kovats RI; Authors: Haken, J.K.; Korhonen, I.O.O., Gas chromatography of homologous esters. XXXII. Capillary chromatography of C1-C18 monochlorinated n-alkyl acetates, J. Chromatogr., 356, 1986, 79-94., Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; Start T: 100 C; CAS no: 79209; Active phase: SE-30; Substrate: Chromosorb W; Data type: Kovats RI; Authors: Zarazir, D.; Chovin, P.; Guiochon, G., Identification of hydroxylic compounds and their derivatives by gas chromatography, Chromatographia, 3, 1970, 180-195., Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Capillary; Start T: 100 C; CAS no: 79209; Active phase: SE-30; Data type: Kovats RI; Authors: Tarjan, G.; Nyiredy, Sz.; Gyor, M.; Lombosi, E.R.; Lombosi, T.S.; Budahegyi, M.V.; Meszaros, S.Y.; Takacs, J.M., Review. Thirtieth Anniversary of the Retention Index According to Kovats in Gas-Liquid Chromatography, J. Chromatogr., 472, 1989, 1-92., Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Capillary; Start T: 80 C; CAS no: 79209; Active phase: SE-30; Data type: Kovats RI; Authors: Tarjan, G.; Nyiredy, Sz.; Gyor, M.; Lombosi, E.R.; Lombosi, T.S.; Budahegyi, M.V.; Meszaros, S.Y.; Takacs, J.M., Review. Thirtieth Anniversary of the Retention Index According to Kovats in Gas-Liquid Chromatography, J. Chromatogr., 472, 1989, 1-92.) NIST Spectra nist ri 509 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.33 mm; Column length: 25 m; Column type: Capillary; Start T: 60 C; CAS no: 79209; Active phase: SE-30; Carrier gas: N2; Data type: Kovats RI; Authors: Haken, J.K.; Korhonen, I.O.O., Gas chromatography of homologous esters. XXXII. Capillary chromatography of C1-C18 monochlorinated n-alkyl acetates, J. Chromatogr., 356, 1986, 79-94., Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 12 ft; Column type: Packed; Start T: 150 C; CAS no: 79209; Active phase: SE-30; Data type: Kovats RI; Authors: Haken, J.K.; Ho, D.K.M.; Vaughan, C.E., Gas chromatography of homologous esters. VII. The retention behaviour of pyruvate esters and related carbonyl and carboxyl compounds, J. Chromatogr., 106, 1975, 317-325., Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 12 ft; Column type: Packed; Start T: 150 C; CAS no: 79209; Active phase: SE-30; Substrate: Celaton (62-72 mesh); Data type: Kovats RI; Authors: Ashes, J.R.; Haken, J.K., Gas chromatography of homologous esters. VI. Structure-retention increments of aliphatic esters, J. Chromatogr., 101, 1974, 103-123., Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Capillary; CAS no: 79209; Active phase: SE-30; Data type: Kovats RI; Authors: Chretien, J.R.; Dubois, J-E., Topological Analysis: A Technique for the Physico-Chemical Exploitation of Retention Data in Gas-Liquid Chromatography, J. Chromatogr., 158, 1978, 43-56.) NIST Spectra nist ri 560 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.22 mm; Column length: 25 m; Column type: Capillary; Start T: 100 C; CAS no: 79209; Active phase: SE-30; Data type: Kovats RI; Authors: Haken, J.K.; Madden, B.G.; Korhonen, I.O.O., Gas chromatography of homologous esters. XX. Capillary column studies of alkyl acetates, chloroacetates, dichloroacetates and trichloroacetates, J. Chromatogr., 256, 1983, 221-229.) NIST Spectra nist ri 525.9 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.22 mm; Column length: 15 m; Column type: Capillary; Start T: 80 C; CAS no: 79209; Active phase: OV-101; Carrier gas: N2; Data type: Kovats RI; Authors: Komarek, K.; Hornova, L.; Churacek, J., Glass capillary gas chromatography of homologous series of esters. Separation of homologous series of esters of halogenated carboxylic acids on a glass capillary column with the non-polar stationary silicone phase OV-101, J. Chromatogr., 244, 1982, 142-147.) NIST Spectra nist ri 506 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 12 ft; Column type: Packed; Start T: 150 C; CAS no: 79209; Active phase: SE-30; Substrate: Celite 560; Data type: Kovats RI; Authors: Germaine, R.W.; Haken, J.K., Gas chromatography of homologous esters. Part 1. Simple aliphatic esters, J. Chromatogr., 43, 1969, 33-42.) NIST Spectra nist ri 510 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 6 m; Column type: Packed; Start T: 80 C; CAS no: 79209; Active phase: SE-30; Carrier gas: He; Substrate: Chromosorb P; Data type: Kovats RI; Authors: Viani, R.; Muggler-Chavan, F.; Reymond, D.; Egli, R.H., 196. Sur la composition de l’arome de cafe, Helv. Chim. Acta, 48(195-196), 1965, 1809-1815.) NIST Spectra nist ri 522.17 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.321 mm; Column length: 60 m; Column type: Capillary; Start T: 80 C; CAS no: 79209; Active phase: DB-5; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Mijin, D.; Antonovic, D.G., The temperature dependence of the retention index for n-alkyl esters of acetic, propionic, cyclohexanecarboxylic, benzoic and phenylacetic acid on DB-1 and DB-5 capillary columns, J. Serb. Chem. Soc., 71(6), 2006, 629-637.) NIST Spectra nist ri 523.7 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.28 mm; Column length: 15 m; Column type: Capillary; Start T: 150 C; CAS no: 79209; Active phase: SE-54; Carrier gas: Ar; Phase thickness: 2.5 um; Data type: Kovats RI; Authors: Grigor’eva, D.N.; Vasil’ev, A.V.; Golovnya, R.V., Variation in retention indices and equivalent chain lengths of homologous series of n-alkyl acetates, n-alkyl methyl ketones, and methyl esters of aliphatic carboxylic acids as a function of homolog number and analysis temperature, Zh. Anal. Khim., 44(1), 1989, 68-73, In original 84-89.) NIST Spectra nist ri 525.7 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.28 mm; Column length: 15 m; Column type: Capillary; Start T: 130 C; CAS no: 79209; Active phase: SE-54; Carrier gas: Ar; Phase thickness: 2.5 um; Data type: Kovats RI; Authors: Grigor’eva, D.N.; Vasil’ev, A.V.; Golovnya, R.V., Variation in retention indices and equivalent chain lengths of homologous series of n-alkyl acetates, n-alkyl methyl ketones, and methyl esters of aliphatic carboxylic acids as a function of homolog number and analysis temperature, Zh. Anal. Khim., 44(1), 1989, 68-73, In original 84-89.) NIST Spectra nist ri 529.7 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.28 mm; Column length: 15 m; Column type: Capillary; Start T: 110 C; CAS no: 79209; Active phase: SE-54; Carrier gas: Ar; Phase thickness: 2.5 um; Data type: Kovats RI; Authors: Grigor’eva, D.N.; Vasil’ev, A.V.; Golovnya, R.V., Variation in retention indices and equivalent chain lengths of homologous series of n-alkyl acetates, n-alkyl methyl ketones, and methyl esters of aliphatic carboxylic acids as a function of homolog number and analysis temperature, Zh. Anal. Khim., 44(1), 1989, 68-73, In original 84-89.) NIST Spectra nist ri 522.4 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.28 mm; Column length: 15 m; Column type: Capillary; Start T: 150 C; CAS no: 79209; Active phase: SE-54; Carrier gas: Ar; Phase thickness: 2.5 um; Data type: Kovats RI; Authors: Grigor’eva, D.N.; Vasil’ev, A.V.; Golovnya, R.V., Variation in retention indices and equivalent chain lengths of homologous series of n-alkyl acetates, n-alkyl methyl ketones, and methyl esters of aliphatic carboxylic acids as a function of homolog number and analysis temperature, Zh. Anal. Khim., 44(1), 1989, 68-73, In original 84-89.) NIST Spectra nist ri 530 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.28 mm; Column length: 15 m; Column type: Capillary; Start T: 110 C; CAS no: 79209; Active phase: SE-54; Carrier gas: Ar; Phase thickness: 2.5 um; Data type: Kovats RI; Authors: Grigor’eva, D.N.; Vasil’ev, A.V.; Golovnya, R.V., Variation in retention indices and equivalent chain lengths of homologous series of n-alkyl acetates, n-alkyl methyl ketones, and methyl esters of aliphatic carboxylic acids as a function of homolog number and analysis temperature, Zh. Anal. Khim., 44(1), 1989, 68-73, In original 84-89.) NIST Spectra nist ri 531 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 12 K/min; Start T: 0 C; End T: 250 C; Start time: 12 min; CAS no: 79209; Active phase: SE-54; Carrier gas: He; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Rembold, H.; Wallner, P.; Nitz, S.; Kollmannsberger, H.; Drawert, F., Volatile components of chickpea (Cicer arietinum L.) seed, J. Agric. Food Chem., 37(3), 1989, 659-662.) NIST Spectra nist ri 529 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Start T: 70 C; CAS no: 79209; Active phase: Apiezon L + KF; Phase thickness: 0.06 um; Data type: Kovats RI; Authors: Svetlova, N.I.; Samusenko, A.L.; Golovnya, R.V., Advantage of the universal equation over the linear equation for the calculation of retention parameters of homologous series in capillary chromatography, J. Hi. Res. Chromatogr. ; Chromatogr. Comm., 9, 1986, 737-740.) NIST Spectra nist ri 472 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 6 m; Column type: Packed; Start T: 50 C; CAS no: 79209; Active phase: Squalane; Carrier gas: N2; Substrate: Chromosorb W-AM; Data type: Kovats RI; Authors: Becerra, M.R.; Sanchez, E.F.; Dominguez, J.A.G.; Munoz, J.G.; Molera, M.J., The use of gaseous and liquid n-paraffins in GC identification of oxidation products of acetondimethyl acetal, J. Chromatogr. Sci., 20, 1982, 363-366.) NIST Spectra nist ri 477 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column type: Packed; Start T: 200 C; CAS no: 79209; Active phase: Porapack Q; Carrier gas: N2; Data type: Kovats RI; Authors: Goebel, K.-J., Gaschromatographische Identifizierung Niedrig Siedender Substanzen Mittels Retentionsindices und Rechnerhilfe, J. Chromatogr., 235, 1982, 119-127.) NIST Spectra nist ri 470 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column type: Packed; Start T: 120 C; CAS no: 79209; Active phase: Apiezon L; Substrate: Celite 545; Data type: Kovats RI; Authors: Bogoslovsky, Yu.N.; Anvaer, B.I.; Vigdergauz, M.S., Chromatographic constants in gas chromatography (in Russian), Standards Publ. House, Moscow, 1978, 192., Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column type: Packed; Start T: 50 C; CAS no: 79209; Active phase: Squalane; Substrate: Chromosorb G; Data type: Kovats RI; Authors: Mira, J.M.; Sanchez, L.G., Polarity of the Gas Chromatographic Stationary Phases and Retention Indices of Aliphatic Esters, Ketones and Alcohols, Anal. Chim. Acta., 50, 1970, 315-321.) NIST Spectra nist ri 474 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column type: Packed; Start T: 160 C; CAS no: 79209; Active phase: Apiezon L; Substrate: Celite 545; Data type: Kovats RI; Authors: Bogoslovsky, Yu.N.; Anvaer, B.I.; Vigdergauz, M.S., Chromatographic constants in gas chromatography (in Russian), Standards Publ. House, Moscow, 1978, 192.) NIST Spectra nist ri 475 (Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column length: 2.25 m; Column type: Packed; Start T: 70 C; CAS no: 79209; Active phase: Apiezon L; Substrate: Celite; Data type: Kovats RI; Authors: Wehrli, A.; Kovats, E., Gas-chromatographische Charakterisierung ogranischer Verbindungen. Teil 3: Berechnung der Retentionsindices aliphatischer, alicyclischer und aromatischer Verbindungen, Helv. Chim. Acta, 7, 1959, 2709-2736., Program type: Isothermal; Col… (show more) umn class: Semi-standard non-polar; Column type: Packed; Start T: 70 C; CAS no: 79209; Active phase: Apiezon L; Data type: Kovats RI; Authors: Bogoslovsky, Yu.N.; Anvaer, B.I.; Vigdergauz, M.S., Chromatographic constants in gas chromatography (in Russian), Standards Publ. House, Moscow, 1978, 192.) NIST Spectra nist ri 832 (Program type: Ramp; Column cl… (show more) ass: Standard polar; Column diameter: 0.2 mm; Column length: 25 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 50 C; End T: 200 C; Start time: 5 min; CAS no: 79209; Active phase: CBP-20; Carrier gas: He; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Shimadzu, Gas chromatography analysis of organic solvents using capillary columns (No. 2), 2003.) NIST Spectra nist ri 810 (Program type: Ramp; Column cl… (show more) ass: Standard polar; Column diameter: 0.25 mm; Column length: 60 m; Column type: Capillary; Heat rate: 3 K/min; Start T: 40 C; End T: 190 C; Start time: 6 min; CAS no: 79209; Active phase: DB-Wax; Carrier gas: He; Data type: Kovats RI; Authors: Shimoda, M.; Shibamoto, T., Isolation and identification of headspace volatiles from brewed coffee with an on-column GC/MS method, J. Agric. Food Chem., 38(3), 1990, 802-804.) NIST Spectra nist ri 827 (Program type: Ramp; Column cl… (show more) ass: Standard polar; Column diameter: 0.25 mm; Column length: 60 m; Column type: Capillary; Heat rate: 3 K/min; Start T: 40 C; End T: 200 C; Start time: 5 min; CAS no: 79209; Active phase: DB-Wax; Carrier gas: He; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Tatsuka, K.; Suekane, S.; Sakai, Y.; Sumitani, H., Volatile constituents of kiwi fruit flowers: simultaneous distillation and extraction versus headspace sampling, J. Agric. Food Chem., 38, 1990, 2176-2180.) NIST Spectra nist ri 828 (Program type: Ramp; Column cl… (show more) ass: Standard polar; Column diameter: 0.25 mm; Column length: 60 m; Column type: Capillary; Heat rate: 3 K/min; Start T: 40 C; End T: 200 C; Start time: 5 min; CAS no: 79209; Active phase: DB-Wax; Carrier gas: He; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Tatsuka, K.; Suekane, S.; Sakai, Y.; Sumitani, H., Volatile constituents of kiwi fruit flowers: simultaneous distillation and extraction versus headspace sampling, J. Agric. Food Chem., 38, 1990, 2176-2180.) NIST Spectra nist ri 823 (Program type: Isothermal; Col… (show more) umn class: Standard polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Start T: 60 C; CAS no: 79209; Active phase: OV-351; Carrier gas: N2; Data type: Kovats RI; Authors: Haken, J.K.; Korhonen, I.O.O., Gas chromatography of homologous esters. XXXII. Capillary chromatography of C1-C18 monochlorinated n-alkyl acetates, J. Chromatogr., 356, 1986, 79-94.) NIST Spectra nist ri 839 (Program type: Isothermal; Col… (show more) umn class: Standard polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Start T: 80 C; CAS no: 79209; Active phase: OV-351; Carrier gas: N2; Data type: Kovats RI; Authors: Haken, J.K.; Korhonen, I.O.O., Gas chromatography of homologous esters. XXXII. Capillary chromatography of C1-C18 monochlorinated n-alkyl acetates, J. Chromatogr., 356, 1986, 79-94.) NIST Spectra nist ri 844 (Program type: Isothermal; Col… (show more) umn class: Standard polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Start T: 100 C; CAS no: 79209; Active phase: OV-351; Carrier gas: N2; Data type: Kovats RI; Authors: Haken, J.K.; Korhonen, I.O.O., Gas chromatography of homologous esters. XXXII. Capillary chromatography of C1-C18 monochlorinated n-alkyl acetates, J. Chromatogr., 356, 1986, 79-94.) NIST Spectra nist ri 877 (Program type: Isothermal; Col… (show more) umn class: Standard polar; Column diameter: 0.32 mm; Column length: 25 m; Column type: Capillary; Start T: 120 C; CAS no: 79209; Active phase: OV-351; Carrier gas: N2; Data type: Kovats RI; Authors: Haken, J.K.; Korhonen, I.O.O., Gas chromatography of homologous esters. XXXII. Capillary chromatography of C1-C18 monochlorinated n-alkyl acetates, J. Chromatogr., 356, 1986, 79-94.) NIST Spectra nist ri 850 (Program type: Isothermal; Col… (show more) umn class: Standard polar; Column length: 2 m; Column type: Packed; Start T: 75 C; CAS no: 79209; Active phase: Carbowax 20M; Carrier gas: N2; Substrate: Kieselgur (60-100 mesh); Data type: Kovats RI; Authors: Goebel, K.-J., Gaschromatographische Identifizierung Niedrig Siedender Substanzen Mittels Retentionsindices und Rechnerhilfe, J. Chromatogr., 235, 1982, 119-127.) NIST Spectra nist ri 798 (Program type: Isothermal; Col… (show more) umn class: Standard polar; Column type: Packed; CAS no: 79209; Active phase: Carbowax 20M; Substrate: Chromosorb; Data type: Kovats RI; Authors: Kevei, E.; Kozma, E., Gaschromatographische Untersuchungsmethoden zur Aromaprufung in gekochtem Schweinefleisch (M. semimembranosus), Nahrung, 20(3), 1976, 243-252.) NIST Spectra nist ri 836 (Program type: Isothermal; Col… (show more) umn class: Standard polar; Column length: 2 m; Column type: Packed; Start T: 100 C Haven't found what you were looking for?
Search for samples, answers to your questions and flashcards
Get an explanation on any taskGet unstuck with the help of our AI assistant in secondsNewHaven't found what you were looking for?
-