Malathion C10H19O6PS2 structure – Flashcards

Flashcard maker : Jacoby Flores

Molecular Formula C10H19O6PS2
Average mass 330.358 Da
Density 1.3±0.1 g/cm3
Boiling Point 385.1±52.0 °C at 760 mmHg
Flash Point 186.7±30.7 °C
Molar Refractivity 77.5±0.3 cm3
Polarizability 30.7±0.5 10-24cm3
Surface Tension 47.2±3.0 dyne/cm
Molar Volume 259.7±3.0 cm3
  • Experimental data
  • Predicted – ACD/Labs
  • Predicted – EPISuite
  • Predicted – ChemAxon
  • Experimental Physico-chemical Properties
    • Experimental Melting Point:

      2.8 °C Jean-Claude Bradley Open Melting Point Dataset 16711, 21780
    • Experimental Boiling Point:

      140 F (60 °C)
      (Decomposes) NIOSH WM8400000
      156-157 °C LabNetwork LN01293226
    • Experimental Vapor Pressure:

      0 mmHg NIOSH WM8400000
    • Experimental Freezing Point:

      37 F (2.7778 °C)
      NIOSH WM8400000
    • Experimental Solubility:

      0.02% NIOSH WM8400000
      CH3OH:50mg/mL MedChem Express http://www.medchemexpress.com/Pidotimod.html
  • Miscellaneous
    • Appearance:

      Deep-brown to yellow liquid with a garlic-like odor. [insecticide] [Note: A solid below 37F.] NIOSH WM8400000
      yellow to brown liquid with an odour of skunk Oxford University Chemical Safety Data (No longer updated) More details
    • Stability:

      Stable. Incompatible with oxidizing agents, metals. Oxford University Chemical Safety Data (No longer updated) More details
    • Toxicity:

      ORL-RAT LD50 2100 mg kg-1, IPR-MUS LD50 985 mg kg-1, ORL-MUS LD50 775 mg kg-1 Oxford University Chemical Safety Data (No longer updated) More details
    • Safety:

      Safety glasses, good ventilation, gloves (Silver Shield). Avoid long-term exposure. Oxford University Chemical Safety Data (No longer updated) More details
    • First-Aid:

      Eye: Irrigate immediately Skin: Soap wash promptly Breathing: Respiratory support Swallow: Medical attention immediately NIOSH WM8400000
    • Exposure Routes:

      inhalation, skin absorption, ingestion, skin and/or eye contact NIOSH WM8400000
    • Symptoms:

      Irritation eyes, skin; miosis, aching eyes, blurred vision, lacrimation (discharge of tears); salivation; anorexia, nausea, vomiting, abdominal cramps, diarrhea, dizziness, confusion, ataxia; rhinorrh
      ea (discharge of thin mucus), headache; chest tightness, wheezing, laryngeal spasm NIOSH WM8400000
    • Target Organs:

      ChE inhibitor TargetMol T1015
      Eyes, skin, respiratory system, liver, blood cholinesterase, central nervous system, cardiovascular system, gastrointestinal tract NIOSH WM8400000
    • Incompatibility:

      Strong oxidizers, magnesium, alkaline pesticides [Note: Corrosive to metals.] NIOSH WM8400000
    • Personal Protection:

      Skin: Prevent skin contact Eyes: Prevent eye contact Wash skin: When contaminated Remove: When wet or contaminated Change: Daily NIOSH WM8400000
    • Exposure Limits:

      NIOSH REL : TWA 10 mg/m 3 [skin] OSHA PEL ?: TWA 15 mg/m 3 [skin] NIOSH WM8400000
    • Drug Status:

      USP, BAN Microsource
      [00330021]
    • Bio Activity:

      AChE MedChem Express HY-B0943
      ChE TargetMol T1015
      Malathion is an organophosphate parasympathomimetic which binds irreversibly to cholinesterase, is an insecticide of relatively low human toxicity. MedChem Express HY-B0943, http://www.medchemexpress.com/Pidotimod.html
      Neuronal Signaling MedChem Express HY-B0943
      Neuronal Signaling; MedChem Express HY-B0943
      Neuroscience TargetMol T1015
  • Gas Chromatography
    • Retention Index (Kovats):

      1931 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Capillary; Start T: 190 C; CAS no: 121755; Active phase: OV-1; Data type: Kovats RI; Authors: Erdmann, F.; Rochholz, G.; Schutz, H., Retention-indices on OV-1 of approximately 170 commonly used pesticides, Mikrochim. Acta, 106, 1992, 219-226.) NIST Spectra nist ri
      1934 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Capillary; Start T: 220 C; CAS no: 121755; Active phase: OV-1; Data type: Kovats RI; Authors: Erdmann, F.; Rochholz, G.; Schutz, H., Retention-indices on OV-1 of approximately 170 commonly used pesticides, Mikrochim. Acta, 106, 1992, 219-226.) NIST Spectra nist ri
      1926 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.53 mm; Column type: Packed; Start T: 210 C; CAS no: 121755; Active phase: SE-30; Carrier gas: N2; Substrate: AW-DMCS; Data type: Kovats RI; Authors: Oyama, N.; Sano, T.; Syoyama, M.; Maeda, K., Studies on systematic analysis of poisonous compounds in forensic chemistry. II. Application of capillary column gas chromatography to substance identification by means of retention indices, Eisei Kagaku, 33(5), 1987, 342-348.) NIST Spectra nist ri
      1938 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 6 K/min; Start T: 100 C; End T: 270 C; CAS no: 121755; Active phase: DB-1; Carrier gas: He; Data type: Kovats RI; Authors: Hall, G.L.; Whitehead, W.E.; Mourer, C.R.; Shibamoto, T., A new gas chromatographic retention index for pesticides and related compounds, J. Hi. Res. Chromatogr. & Chromatogr. Comm., 9, 1986, 266-271.) NIST Spectra nist ri
      1930 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.20 mm; Column length: 25 m; Column type: Capillary; Start T: 250 C; CAS no: 121755; Active phase: SPB-1; Carrier gas: He; Data type: Kovats RI; Authors: Lora-Tamayo, C.; Rams, M.A.; Chacon, J.M.R., Gas Chromatographic Data for 187 Nitrogen- or Phosphorus-Containing Drugs and Metabolites of Toxicological Interest Analysed on Methyl Silicone Capillary Columns, J. Chromatogr., 374, 1986, 73-85.) NIST Spectra nist ri
      1917 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; CAS no: 121755; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W HP; Data type: Kovats RI; Authors: Osselton, M.D.; Snelling, R.D., Chromatographic Identification of Pesticides, J. Chromatogr., 368, 1986, 265-271.) NIST Spectra nist ri
      1920 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.49 mm; Column length: 25 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 100 C; End T: 275 C; End time: 15 min; Start time: 2 min; CAS no: 121755; Active phase: SE-30; Phase thickness: 1.14 um; Data type: Kovats RI; Authors: Schepers, P.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A., Applicability of capillary gas chromatography to substance identification in toxicology by means of retention indices, J. Forensic Sci., 27(1), 1982, 49-60.) NIST Spectra nist ri
      1922 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 300 C; End time: 12 min; Start time: 2 min; CAS no: 121755; Active phase: SE-30; Carrier gas: He; Phase thickness: 0.45 um; Data type: Kovats RI; Authors: Schepers, P.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A., Applicability of capillary gas chromatography to substance identification in toxicology by means of retention indices, J. Forensic Sci., 27(1), 1982, 49-60.) NIST Spectra nist ri
      1962 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; Description: 50C(1min)=>20C/min=>150C=>10C/min=>280C(4min); CAS no: 121755; Active phase: HP-5; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Tanabe, A.; Mitobe, H.; Kawata, K.; Sakai, M.; Yasuhara, A., New monitoring system for ninety pesticides and related compounds in river water by solid-phase extraction with determination by gas chromatography/mass spectrometry, J. AOAC Int., 83(1), 2000, 61-77.) NIST Spectra nist ri
    • Retention Index (Normal Alkane):

      1945.3 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 50C(1min) =>20C/min =>120C => 5C/min => 300C(10min); CAS no: 121755; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Shimadzu Corporation, Analysis of 124 pesticides with capillary GC-FTD and GC-ECD, 2003.) NIST Spectra nist ri
      1928 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 50 C; End T: 280 C; Start time: 4 min; CAS no: 121755; Active phase: CP-Sil5 CB MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Dalluge, J.; van Rijn, M.; Beens, J.; Vreuls, R.J.J.; Brinkman, U.A.Th., Comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometric detection applied to the determination of pesticides in food extracts, J. Chromatogr. A, 965, 2002, 207-217., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Capillary; CAS no: 121755; Active phase: Methyl Silicone; Data type: Normal alkane RI; Authors: Zenkevich, I.G.; Ostroukhova, O.K.; Dolzhenko, V.I., Optimum analytical parameters for chromatographic characterization of pesticides, J. Anal. Chem. USSR (Engl. Transl.), 57(1), 2002, 35-39, In original 43-48.) NIST Spectra nist ri
      1937.6 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 55 C; End T: 210 C; End time: 30 min; Start time: 2 min; CAS no: 121755; Active phase: DB-1; Data type: Normal alkane RI; Authors: Albanis, T.A.; Hela, D.G., Multi-residue pesticide analysis in environmental water samples using solid-phase extraction discs and gas chromatography with flame thermionic and mass-selective detection, J. Chromatogr. A, 707, 1995, 283-292.) NIST Spectra nist ri
      1928.4 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.2 mm; Column length: 12 m; Column type: Capillary; Heat rate: 18 K/min; Start T: 60 C; End T: 265 C; Start time: 1 min; CAS no: 121755; Active phase: HP-1; Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Liao, W.; Joe, T.; Cusick, W.G., Multiresidue screening method for fresh fruits and vegetables with gas chromatographic/mass spectrometric detection, J. Ass. Offic. Anal. Chem, 74(3), 1991, 554-565.) NIST Spectra nist ri
      1924.7 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; CAS no: 121755; Active phase: OV-101; Carrier gas: N2; Substrate: GAs Chrom Q (80-100 mesh); Data type: Normal alkane RI; Authors: Omura, M.; Hashimoto, K.; Ohta, K.; Iio, T.; Ueda, S.; Ando, K.; Fujiu, Y.; Hiraide, H., Effective application of the relative retention time diagram for gas chromatographic analysis of pesticides, J. Agric. Food Chem., 39(12), 1991, 2200-2205.) NIST Spectra nist ri
      1913 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Capillary; CAS no: 121755; Active phase: Ultra-1; Data type: Normal alkane RI; Authors: Tameo, O.; Kiyos, I., Simultaneous determination of pesticides by capillary gas chromatography, Cannot be traslated (in Japan), 14(2), 1991, 109-122.) NIST Spectra nist ri
      1938.9 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 1.1 m; Column type: Packed; Heat rate: 8.5 K/min; Start T: 50 C; End T: 300 C; CAS no: 121755; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W HP; Data type: Normal alkane RI; Authors: Saxton, W.L., Emergence temperature indices and relative retention times of pesticides and industrial chemicals determined by linear programmed temperature gas chromatography, J. Chromatogr., 393, 1987, 175-194.) NIST Spectra nist ri
      1930 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 1 m; Column type: Packed; Start T: 190 C; CAS no: 121755; Active phase: OV-1; Carrier gas: Helium; Substrate: Chromosorb W AW DMCS; Data type: Normal alkane RI; Authors: TSunoda, N., Simultaneous determination of organophosphorous pesticides in forencis chemistry by gas-liquid chromatography with hydrogen flame ionization detector, Eisei Kagaku, 32(2), 1986, 91-100., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 1 m; Column type: Packed; Heat rate: 4 K/min; Start T: 140 C; End T: 210 C; End time: 20 min; CAS no: 121755; Active phase: OV-1; Carrier gas: Helium; Substrate: Chromosorb W AW DMCS; Data type: Normal alkane RI; Authors: TSunoda, N., Simultaneous determination of organophosphorous pesticides in forencis chemistry by gas-liquid chromatography with hydrogen flame ionization detector, Eisei Kagaku, 32(2), 1986, 91-100.) NIST Spectra nist ri
      1938.7 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.247 mm; Column length: 15 m; Column type: Capillary; Description: 1 min at 90 C; 90-150 C at 20 deg/min; 150-250 C at 5 deg/min; hold at 250 C for elution of last component; CAS no: 121755; Active phase: SE-30; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Ripley, B.D.; Braun, H.E., Retention time data for organochlorine, organophosphorus, and organonitrogen pesticides on SE-30 capillary column and application of capillary gas chromatography to pesticide residue analysis, J. Ass. Offic. Anal. Chem, 66(5), 1983, 1084-1095.) NIST Spectra nist ri
      1920 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; Heat rate: 2.5 K/min; Start T: 120 C; End T: 200 C; CAS no: 121755; Active phase: SE-30; Substrate: Gas Chrom P; Data type: Normal alkane RI; Authors: Marozzi, E.; Gambaro, V.; Saligari, E.; Mariani, R.; Lodi, F., Use of the retention index in gas chromatographic studies of drugs, J. Anal. Toxicol., 6, 1982, 185-192.) NIST Spectra nist ri
      1917 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Other; CAS no: 121755; Active phase: Methyl Silicone; Data type: Normal alkane RI; Authors: Ardrey, R.E.; Moffat, A.C., Gas-liquid chromatographic retention indices of 1318 substances of toxicological interest on SE-30 or OV-1 stationary phase, J. Chromatogr., 220, 1981, 195-252.) NIST Spectra nist ri
      1931.7 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 4 K/min; Start T: 200 C; End T: 290 C; CAS no: 121755; Active phase: SE-30; Data type: Normal alkane RI; Authors: Krijgsman, W.; van de Kamp, C.G., Analysis of organophosphorus pesticides by capillary gas chromatography with flame photometric detection, J. Chromatogr., 117, 1976, 201-205.) NIST Spectra nist ri
      1942.8 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 2.4 m; Column type: Packed; Heat rate: 10 K/min; Start T: 150 C; End T: 300 C; CAS no: 121755; Active phase: OV-101; Substrate: Gas Chrom Q; Data type: Normal alkane RI; Authors: Bowman, M.C.; Beroza, M., GLC Retention Times of Pesticides and Metabolites Containing Phosphorus and Sulfur on Four Thermally Stable Columns, J. Ass. Offic. Anal. Chem, 53(3), 1970, 499-508.) NIST Spectra nist ri
      1932.2 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 3 ft; Column type: Packed; CAS no: 121755; Active phase: DC-200; Carrier gas: N2; Substrate: Gas Chrom Q; Data type: Normal alkane RI; Authors: Watts, R.R.; Storherr, R.W., Gas chromatography of organophosphorus pesticides: Retention times and response data on three columns, J. Ass. Offic. Anal. Chem, 52(3), 1969, 513-521.) NIST Spectra nist ri
      1963 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 50 0C(1 min) ^ 25 0C/min -> 125 0C ^ 10 0C/min -> 300 0C (10 min); CAS no: 121755; Active phase: 5 % Phenyl methyl siloxane; Carrier gas: Helium; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Department of Food Safety, Ministry of Health; Welfare, Analytical methods for residual compositional substances of agricultural chemicals, feed aadditives, and veterinary drugs in foods, 2006.) NIST Spectra nist ri
      1965 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 50 0C(1 min) ^ 25 0C/min -> 125 0C ^ 10 0C/min -> 300 0C (10 min); CAS no: 121755; Active phase: 5 % Phenyl methyl siloxane; Carrier gas: Helium; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Department of Food Safety, Ministry of Health; Welfare, Analytical methods for residual compositional substances of agricultural chemicals, feed aadditives, and veterinary drugs in foods, 2006., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Heat rate: 4 K/min; Start T: 125 C; End T: 250 C; End time: 10 min; Start time: 10 min; CAS no: 121755; Active phase: RTX-5; Carrier gas: He; Phase thickness: 0.5 um; Data type: Normal alkane RI; Authors: Restek, Restek International, 1999 Product Guide, 1(1), 1999, 578-591, In original 578-591., Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column type: Capillary; CAS no: 121755; Active phase: DB-5; Data type: Normal alkane RI; Authors: Soderstrom, M.; White, E.; Abis, L.; Sliwakowski, M., Summary report of the eight meeting of the validation group for the updating of the central OPCW analytical database, 28-29 November 2000, CS-2001-2242, Verification Division S/239/2001, 2001, 14.) NIST Spectra nist ri
      1951.5 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 80C(1min) => 10C/min =>160C (5min) => 3C/min =>240C =>25C/min =>280C(10min); CAS no: 121755; Active phase: DB-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Chu, X.-G.; Hu, X.-Z.; Yao, H.-Y., Determination of 266 pesticide residues in apple juice by matrix solid-phase dispersion and gas chromatography-mass selective detection, J. Chromatogr. A, 1063, 2005, 201-210.) NIST Spectra nist ri
      1962 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 50 0C (1 min) ^ 20 0C/min -> 150 0C ^ 10 0C/min -> 280 0C; CAS no: 121755; Active phase: HP-5; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Kawara, K.; Asada, T.; Oikawa, K.; Tanabe, A., Multiresidue determination of pesticides in sediments by ultrasonically assisted extraction and gas chromatography/mass spectrometry, J. AOAC International, 88(5), 2005, 1440-1451.) NIST Spectra nist ri
      1959.2 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 70C(2min) =>25C/min=>150C=> 3C/min =>200C =>8C/min=> 280C(10min); CAS no: 121755; Active phase: ZB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Albero, B.; Sanchez-Brunete, C.; Tadeo, J.L., Analysis of pesticides in honey by solid-phase extraction and gas chromatography-mass spectrometry, J. Agric. Food Chem., 52, 2004, 5828-5835.) NIST Spectra nist ri
      1945.9 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 80C(2min) =>15C/min =>190C(4min) => 10C/min => 290C(6min); CAS no: 121755; Active phase: CP-Sil 8CB-MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Goncalves, C.; Alpendurada, M.F., Solid-phase micro-extraction-gas chromatography-(tandem) mass spectrometry as a tool for pesticide residue analysis in water samples at high sensitivity and selectivity with confirmation capabilities, J. Chromatogr. A, 1026, 2004, 239-250.) NIST Spectra nist ri
      1959.6 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 70C(2min)=> 25C/min =>150C=> 3C/min =>200C =>8C/min=>280C(10min); CAS no: 121755; Active phase: ZB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Sanchez-Brunete, C.; Albero, B.; Tadeo, J.L., Multiresidue determination of pesticides in soil by gas chromatography-mass spectrometry detection, J. Agric. Food Chem., 52, 2004, 1445-1451.) NIST Spectra nist ri
      1953.2 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 70C(2min) =>25C/min =>150C=>3C/min => 200C=> 8C/min =>280C(10min); CAS no: 121755; Active phase: HP-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Wong, J.W.; Webster, M.G.; Bezabeh, D.Z.; Hengel, M.J.; Ngim, K.K.; Krynitsky, A.J.; Ebeler, S.E., Multiresidue determination of pesticides in malt beverages by capillary gas chromatography with mass spectrometry and selected ion monitoring, J. Agric. Food Chem., 52, 2004, 6361-6372.) NIST Spectra nist ri
      1962.2 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 15 K/min; Start T: 57 C; End T: 290 C; End time: 15 min; Start time: 1.5 min; CAS no: 121755; Active phase: HP-5; Carrier gas: He; Phase thickness: 0.2 um; Data type: Normal alkane RI; Authors: Haib, J.; Hofer, I.; Renaud, J.-M., Analysis of multiple pesticide residues in tobacco using pressurized liquid extraction, automated solid-phase extraction clean-up and gas chromatography-tandem mass spectrometry, J. Chromatogr. A, 1020, 2003, 173-187.) NIST Spectra nist ri
      1953.1 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 50C(1min) =>20C/min =>120C => 5C/min => 300C(10min); CAS no: 121755; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Shimadzu Corporation, Analysis of 124 pesticides with capillary GC-FTD and GC-ECD, 2003.) NIST Spectra nist ri
      1926.7 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 50 C (1.5 min) ^ 30 C/min -> 180 C ^ 10 C/min -> 275 C (15 min); CAS no: 121755; Active phase: RTX-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Dabrowski, L.; Giergielewicz-Mozajska, H.; Biziuk, M.; Gaca, J.; Namiesnik, J., Some aspects of the analysis of environmental pollutants in sediments using pressurized liquid extraction and gas chromatography-mass spectrometry, J. Chromatogr. A, 957, 2002, 59-67.) NIST Spectra nist ri
      1941.1 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 70 C (3.5 min) ^ 50 C/min -> 150 C ^ 5 C/min -> 180 C (5 min) ^ 4 C/min -> 205 C (5 min) ^ 4 C/min -> 300 C (5 min); CAS no: 121755; Active phase: DB-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Martinez Vidal, J.L.; Arrebola, F.J.; Mateu-Sanchez, M., Application of gas chromatography-tandem mass spectrometry to the analysis of pesticides in fruits and vegetables, J. Chromatogr. A, 959, 2002, 203-213.) NIST Spectra nist ri
      1946 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 60C (2.7min) => 25C/min =>173C(2min) =>2C/min =>195C=>25C/min =>270C; CAS no: 121755; Active phase: SE-54; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Russo, M.V.; Campanella, L.; Avino, P., Determination of organophosphorus pesticide residues in human tissues by capillary gas chromatography-negative chemical ionization mass spectrometry analysis, J. Chromatogr. B, 780, 2002, 431-441.) NIST Spectra nist ri
      1932.7 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 25 K/min; Start T: 50 C; End T: 250 C; End time: 5 min; Start time: 4 min; CAS no: 121755; Active phase: HP-5MS; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Sanchez-Brunete, C.; Albero, B.; Miguel, E.; Tadeo, J.L., Determination of insecticides in honey by matrix solid-phase dispersion and gas chromatography with nitrogen-phosphorus detection and mass spectrometric confirmation, J. AOAC Int., 85(1), 2002, 128-133.) NIST Spectra nist ri
      1970 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column type: Capillary; CAS no: 121755; Active phase: DB-5; Data type: Normal alkane RI; Authors: Soderstrom, M.; White, E.; Abis, L.; Sliwakowski, M., Summary report of the eight meeting of the validation group for the updating of the central OPCW analytical database, 28-29 November 2000, CS-2001-2242, Verification Division S/239/2001, 2001, 14.) NIST Spectra nist ri
      1975 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column type: Capillary; CAS no: 121755; Active phase: DB-5; Data type: Normal alkane RI; Authors: Soderstrom, M.; White, E.; Abis, L.; Sliwakowski, M., Summary report of the eight meeting of the validation group for the updating of the central OPCW analytical database, 28-29 November 2000, CS-2001-2242, Verification Division S/239/2001, 2001, 14.) NIST Spectra nist ri
      1986 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column type: Capillary; CAS no: 121755; Active phase: DB-5; Data type: Normal alkane RI; Authors: Soderstrom, M.; White, E.; Abis, L.; Sliwakowski, M., Summary report of the eight meeting of the validation group for the updating of the central OPCW analytical database, 28-29 November 2000, CS-2001-2242, Verification Division S/239/2001, 2001, 14.) NIST Spectra nist ri
      1950.1 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 25 m; Column type: Capillary; Description: 100C(1min) => 30C/min=> 150C(2min) => 3C/min=> 205C => 10C/min =>260C(29min); CAS no: 121755; Active phase: SE-54; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Stan, H.-J., Pesticide residue analysis in foodstuffs applying capillary gas chromatography with mass spectrometric detection State-of-the-art use of modified DFG-multimethod S19 and automated data evaluation, J. Chromatogr. A, 892, 2000, 347-377.) NIST Spectra nist ri
      1954.2 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 50 C (1.13 min) ^ 30 C/min -> 150 C ^ 3 C/min -> 205 C ^ 10 C/min -> 250 C (20 min); CAS no: 121755; Active phase: HP-5; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Cook, J.; Engel, M.; Wylie, P.; Quimby, B., Multiresidue screening of pesticides in foods using retention time locking, GC-AED, database search, and GC/MS identification, J. AOAC Int., 82(2), 1999, 313-326.) NIST Spectra nist ri
      1972.5 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 6 K/min; Start T: 60 C; End T: 260 C; End time: 12 min; CAS no: 121755; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Mogadati, P.; Louis, J.B.; Rosen, J.D., Multiresidue determination of pesticides in high-organic-content soils by solid-phase extraction and gas chromatography/mass spectrometry, J. AOAC Int., 82(3), 1999, 705-715.) NIST Spectra nist ri
      1951.4 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 2.5 mm; Column length: 30 m; Column type: Capillary; Description: 60 0C (1 min) ^ 15 0C/min -> 180 0C (4 min) ^ 5 0C/min -> 205 0C ^ 20 0C/min -> 295 0C (5 min); overall run time is 27.5 min; CAS no: 121755; Active phase: HP-5; Carrier gas: He; Phase thickness: 2.5 um; Data type: Normal alkane RI; Authors: Johnson, P.D.; Rimmer, D.A.; Brown, R.H., Adaptation and application of a multi-residue method for the determination of a range of pesticides, including phenoxy acid herbicides in vegetation, ased on high-resolution gel permeation chromatographic clean-up and gas chromatographic analysis with mass-selective detection, J. Chromatogr. A, 765, 1997, 3-11.) NIST Spectra nist ri
      1945.8 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 29 m; Column type: Capillary; Description: 80 C (1 min) ^ 6 C/min -> 200 C (3 min) ^ 6 C/min -> 260 C (8 min); CAS no: 121755; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Papadopoulou-Mourkidou, E.; Patsias, J.; Kotopoulou, A., Determination of pesticides in soils by gas chromatography-ion trap mass spectrometry, J. AOAC Int., 80(2), 1997, 447-454.) NIST Spectra nist ri
      1969 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 50 0C (1 min) ^ 20 0C/min -> 200 0C ^ 10 0C/min -> 280 0C (2 min); CAS no: 121755; Active phase: DB-5; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Kawata, K.; Mukai, H.; Tanabe, H.; Yasuhara, A., Annual variation of insecticides in precipitation in rural Japan, Bull. Environ. Contam. Toxicol., 57, 1996, 853-858.) NIST Spectra nist ri
      1935.8 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Description: 80(1)-6^ ->200(3)-6^ -> 260(10); CAS no: 121755; Active phase: HP-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Patsias, J.; Papadopoulou-Mourkidou, E., Rapid method for the analysis of a variety of chemical classes of pesticides in surface and ground waters by off-line solid phase extraction and gas chromatography-ion trap mass spectrometry, J. Chromatogr. A, 740, 1996, 83-98.) NIST Spectra nist ri
      1956.7 (Program type: Ramp

      Get an explanation on any task
      Get unstuck with the help of our AI assistant in seconds
      New