Lignocaine C14H22N2O structure – Flashcards
Flashcard maker : Jamie Hutchinson
Contents
Molecular Formula | C14H22N2O |
Average mass | 234.337 Da |
Density | 1.0±0.1 g/cm3 |
Boiling Point | 350.8±30.0 °C at 760 mmHg |
Flash Point | 166.0±24.6 °C |
Molar Refractivity | 72.4±0.3 cm3 |
Polarizability | 28.7±0.5 10-24cm3 |
Surface Tension | 39.1±3.0 dyne/cm |
Molar Volume | 228.3±3.0 cm3 |
- Experimental data
- Predicted – ACD/Labs
- Predicted – EPISuite
- Predicted – ChemAxon
- Predicted – Mcule
- Experimental Physico-chemical Properties
-
Experimental Melting Point:
69 °C TCI L0156 68.5 °C Jean-Claude Bradley Open Melting Point Dataset 16750, 17312, 21841, 28210 -
Experimental LogP:
2.359 Vitas-M STK552033 -
Experimental Solubility:
10 mM in DMSO MedChem Express HY-B0185 DMSO 47 mg/mL (200 mM); Water 9 mg/mL (38 mM) MedChem Express HY-B0185 Soluble to 100 mM in ethanol Tocris Bioscience 3057
-
- Predicted Physico-chemical Properties
-
Predicted Melting Point:
69 °C TCI 69 °C TCI L0156
-
- Miscellaneous
-
Safety:
GHS07 Biosynth W-108233 H302 Biosynth W-108233 IRRITANT Matrix Scientific 054650 Warning Biosynth W-108233 -
Target Organs:
EGFR inhibitor;Sodium Channel inhibitor TargetMol T0468 -
Bio Activity:
Anasthetic and class Ib antiarrhythmic agent. Blocks voltage-gated sodium channels in the inactivated state. Tocris Bioscience 3057 EGFR;Sodium channel TargetMol T0468 Ion Channels Tocris Bioscience 3057 Lidocaine, an amide local anesthetic, has anti-inflammatory properties in vitro and in vivo, possibly due to an attenuation of pro-inflammatory cytokines, intracellular adhesion molecule-1 (ICAM-1), a
nd reduction of neutrophils influx. MedChem ExpressLidocaine, an amide local anesthetic, has anti-inflammatory properties in vitro and in vivo, possibly due to an attenuation of pro-inflammatory cytokines, intracellular adhesion molecule-1 (ICAM-1), and reduction of neutrophils influx.; Target: ; Lidocaine is a common local anesthetic and antiarrhythmic drug. MedChem Express HY-B0185 Lidocaine, an amide local anesthetic, has anti-inflammatory properties in vitro and in vivo, possibly due to an attenuation of pro-inflammatory cytokines, intracellular adhesion molecule-1 (ICAM-1), and reduction of neutrophils influx.;Target: Lidocaine is a common local anesthetic and antiarrhythmic drug. Lidocaine is used topically to relieve itching, burning and pain from skin inflammations, injected as a dental anesthetic or as a local anesthetic for minor surgery. Lidocaine, the first amino amide?type local anesthetic, was first synthesized under the name xylocaine by Swedish chemist Nils Lofgren in 1943. His colleague Bengt Lundqvist performed the first injection anesthesia experiments on himself.Lidocaine is approximately 95% metabolized (dealkylated) in the liver by CYP3A4 to the pharmacologically-active metabolites monoethylglycinexylidide (MEGX) and then subsequently to the inactive glycine xylidide. MEGX has a longer half life than lidocaine but also is a less potent s MedChem Express HY-B0185 Local anaesthetic; Zerenex Molecular
[ZBioX-0631]Membrane Transporter/Ion Channel; JAK/STAT Signaling TargetMol T0468 Na+ channel blocker Tocris Bioscience 3057 Others MedChem Express HY-B0185 Sodium Channels Tocris Bioscience 3057 Voltage-gated Sodium Channels Tocris Bioscience 3057
-
- Gas Chromatography
-
Retention Index (Kovats):
1966 (estimated with error: 83) NIST Spectra mainlib_113841, replib_250604, replib_241768, replib_246327, replib_373972, replib_379695 1875 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.22 mm; Column length: 25 m; Column type: Capillary; Start T: 200 C; CAS no: 137586; Active phase: BP-1; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 32(6), 1987, 1574-1586., Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; Start T: 180 C; CAS no: 137586; Active phase: SE-30; Carrier gas: N2; Substrate: 1% se-30 on Anachrom ABS(80-100mesh); Data type: Kovats RI; Authors: Musumarra, G.; Scarlata, G.; Romano, G.; Cappello, G.; Clementi, S.; Giulietti, G., Qualitative organic analysis. Part 2. Identification of drugs by principal components analysis of standardized TLC data in four eluent systems and of retention indices on SE 30, J. Anal. Toxicol., 11, 1987, 154-163., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 0.60 m; Column type: Packed; Heat rate: 30 K/min; Start T: 100 C; End T: 310 C; End time: 5 min; Start time: 3 min; CAS no: 137586; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb G HP; Data type: Kovats RI; Authors: Maurer, H.H., Identification of antiarrhythmic drugs and their metabolites in urine, Arch. Toxicol., 64(3), 1990, 218-230.) NIST Spectra nist ri 1882 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column diameter: 0.53 mm; Column length: 25 m; Column type: Capillary; Start T: 200 C; CAS no: 137586; Active phase: BP-1; Carrier gas: N2; Phase thickness: 1 um; Data type: Kovats RI; Authors: Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 32(6), 1987, 1574-1586.) NIST Spectra nist ri 1850 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; Start T: 260 C; CAS no: 137586; Active phase: SE-30; Substrate: Anakrom ABS; Data type: Kovats RI; Authors: Mari, F.; Bertol, E.; Tosti, M., Benzoyltropeine, an unusual substance in street heroin samples, Bull. Narc., 1, 1984, 59-67.) NIST Spectra nist ri 1900 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 2 m; Column type: Packed; Start T: 220 C; CAS no: 137586; Active phase: SE-30; Substrate: Anakrom ABS; Data type: Kovats RI; Authors: Mari, F.; Bertol, E.; Tosti, M., Benzoyltropeine, an unusual substance in street heroin samples, Bull. Narc., 1, 1984, 59-67.) NIST Spectra nist ri 1869 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.49 mm; Column length: 25 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 100 C; End T: 275 C; End time: 15 min; Start time: 2 min; CAS no: 137586; Active phase: SE-30; Phase thickness: 1.14 um; Data type: Kovats RI; Authors: Schepers, P.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A., Applicability of capillary gas chromatography to substance identification in toxicology by means of retention indices, J. Forensic Sci., 27(1), 1982, 49-60.) NIST Spectra nist ri 1859 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Packed; Start T: 170 C; CAS no: 137586; Active phase: OV-101; Data type: Kovats RI; Authors: Delbeke, F.T.; Debackere, M.; Desmet, N., Detection of some local anaesthetics in horse urine and plasma by gas-liquid chromatography, J. Chromatogr., 206, 1981, 594-599.) NIST Spectra nist ri 1866 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Packed; Start T: 180 C; CAS no: 137586; Active phase: OV-101; Data type: Kovats RI; Authors: Delbeke, F.T.; Debackere, M.; Desmet, N., Detection of some local anaesthetics in horse urine and plasma by gas-liquid chromatography, J. Chromatogr., 206, 1981, 594-599.) NIST Spectra nist ri 1860 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column length: 6 ft; Column type: Packed; CAS no: 137586; Active phase: OV-101; Carrier gas: N2; Substrate: Chromosorb W; Data type: Kovats RI; Authors: McLinden, V.J.; Stenhouse, A.M., A chromatography system for drug identification, Forensic Sci. Int., 13, 1979, 71-79.) NIST Spectra nist ri 1885 (Program type: Isothermal; Col… (show more) umn class: Standard non-polar; Column type: Packed; Start T: 200 C; CAS no: 137586; Active phase: OV-1; Data type: Kovats RI; Authors: Berninger, H.; Moller, M.R., Retentionsindices zur gaschromatographischen Identifizierung von Arzneimitteln, Arch. Toxicol., 37, 1977, 295-305.) NIST Spectra nist ri -
Retention Index (Normal Alkane):
1875 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Capillary; CAS no: 137586; Active phase: HP-1; Carrier gas: Helium; Data type: Normal alkane RI; Authors: Grigor’ev, A.M.; Bozhko, E.S.; Rudakova, L.V., Use of correlation between retention indices on low-polarity phases for screening comp-lex mixtures by gas chromatography-mass spectrometry, Rus. J. Anal. Chem., 64(2), 2009, 140-143, In original 156-159.) NIST Spectra nist ri 1876.9 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column length: 30 m; Column type: Capillary; Heat rate: 7 K/min; Start T: 70 C; End T: 270 C; End time: 5 min; Start time: 2 min; CAS no: 137586; Active phase: HP-1; Carrier gas: He; Phase thickness: 0.88 um; Data type: Normal alkane RI; Authors: de Zeeuw, R.A.; Wijsbeek, J.; Franke, J.P., SPEC Disc solid-phase extraction for rapid broad-spectrum drug screening in urine, J. Anal. Toxicol., 24, 2000, 97-101.) NIST Spectra nist ri 1841 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.20 mm; Column length: 12 m; Column type: Capillary; CAS no: 137586; Active phase: Polymethylsiloxane, (PMS-20000); Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Gambaro, V.; Saligari, E.; Froldi, R.; Bianchi, L., Analysis of street drugs by means of HRGC, Bollettino Chimico Farmaceutica, 36(4), 1997, 359-367.) NIST Spectra nist ri 1842 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 185 C; End T: 270 C; CAS no: 137586; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.2 um; Data type: Normal alkane RI; Authors: Phillips, A.M.; Logan, B.K.; Stafford, D.T., Further applications for capillary gas chromatography in routine quantitative toxicological analyses, J. Hi. Res. Chromatogr., 13, 1990, 754-758., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.20 mm; Column length: 12 m; Column type: Capillary; CAS no: 137586; Active phase: Polymethylsiloxane, (PMS-20000); Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Gambaro, V.; Saligari, E.; Froldi, R.; Bianchi, L., Analysis of street drugs by means of HRGC, Bollettino Chimico Farmaceutica, 36(4), 1997, 359-367., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 100 C; End T: 295 C; CAS no: 137586; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri 1870 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.20 mm; Column length: 12 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 160 C; End T: 300 C; CAS no: 137586; Active phase: Polymethylsiloxane, (PMS-20000); Carrier gas: He; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Gambaro, V.; Saligari, E.; Froldi, R.; Bianchi, L., Analysis of street drugs by means of HRGC, Bollettino Chimico Farmaceutica, 36(4), 1997, 359-367., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Other; CAS no: 137586; Active phase: Methyl Silicone; Data type: Normal alkane RI; Authors: Ardrey, R.E.; Moffat, A.C., Gas-liquid chromatographic retention indices of 1318 substances of toxicological interest on SE-30 or OV-1 stationary phase, J. Chromatogr., 220, 1981, 195-252.) NIST Spectra nist ri 1856 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Description: 120 0X ^ 8 0C/min -; 270 0C ^ 25 0C/min -; 300 0C (5 min); CAS no: 137586; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.26 mm; Column length: 30 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 22 min; Start time: 1 min; CAS no: 137586; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Manca, D.; Ferron, L.; Weber, J-P., A System for Toxicological Screening by Capillary Gas Chromatography with Use of Drug Retention Index Based on Nitrogen-Containing Reference Compounds, Clin. Chem., 35(4), 1989, 601-607.) NIST Spectra nist ri 1844 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column length: 10 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 130 C; End T: 230 C; CAS no: 137586; Active phase: DB-1; Carrier gas: He; Phase thickness: 2.65 um; Data type: Normal alkane RI; Authors: Anderson, W.H.; Fuller, D.C., A simplified procedure for the isolation, characterization, and identification of weak acid and neutral drugs from whole blood, J. Anal. Toxicol., 11, 1987, 198-204.) NIST Spectra nist ri 1852 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 50 C; End T: 300 C; CAS no: 137586; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri 1854 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; CAS no: 137586; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri 1857 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Description: 120 0X ^ 8 0C/min -; 270 0C ^ 25 0C/min -; 300 0C (5 min); CAS no: 137586; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri 1858 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Description: 120 0X ^ 8 0C/min -; 270 0C ^ 25 0C/min -; 300 0C (5 min); CAS no: 137586; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32.) NIST Spectra nist ri 1860 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; CAS no: 137586; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 2 m; Column type: Packed; Heat rate: 2.5 K/min; Start T: 120 C; End T: 200 C; CAS no: 137586; Active phase: SE-30; Substrate: Gas Chrom P; Data type: Normal alkane RI; Authors: Marozzi, E.; Gambaro, V.; Saligari, E.; Mariani, R.; Lodi, F., Use of the retention index in gas chromatographic studies of drugs, J. Anal. Toxicol., 6, 1982, 185-192.) NIST Spectra nist ri 1865 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 137586; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W AW DMS; Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can.Soc.Forens.Sci.J., 9(2), 1975, 69-74., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 6 ft; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 137586; Active phase: SE-30; Carrier gas: Nitrogen; Substrate: Chromosorb W AW DMS (80-100 mesh); Data type: Normal alkane RI; Authors: Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can. Soc. Forens. Sci. J., 9(2), 1976, 69-74.) NIST Spectra nist ri 1924 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.20 mm; Column length: 25 m; Column type: Capillary; Description: 50 0C (0.5 min) ^ 99 0C/min -; 100 0C (1 min) ^ 15 0C/min -; 280 0C (20 min); CAS no: 137586; Active phase: 5 % Phenyl methyl siloxane; Phase thickness: 0.33 um; Data type: Normal alkane RI; Authors: Grigoriev, A.M.; Savchuk, S.A., Correlation of the parameters of screening libraries of the gas-chromatographic retention data, Rus. J. Anal. Chem. (Engl. Transl.), 65(4), 2010, 388-397, In original 400-409.) NIST Spectra nist ri 1885.9 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 70 C; End T: 320 C; End time: 5 min; Start time: 0.5 min; CAS no: 137586; Active phase: BPX-5; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Song, S.M.; Marriott, P.; Wynne, P., Comprehensive two-dimensional gas chromatography-quadrupole mass spectrometric analysis of drugs, J. Chromatogr. A, 1058, 2004, 223-232.) NIST Spectra nist ri 1875.2 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 15 m; Column type: Capillary; Description: 100 0C (0.4 min) ^ 25 0C/min -; 200 0C ^ 10 0C/min -; 290 0C (10 min); CAS no: 137586; Active phase: HG-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Rasanen, I.; Kontinen, I.; Nokua, J.; Ojanpera, I.; Vuori, E., Precise gas chromatography with retention time locking in comprehensive toxicological screening for drugs in blood, J. Chromatogr. B, 788, 2003, 243-250.) NIST Spectra nist ri 1872.7 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.2 mm; Column length: 12.5 m; Column type: Capillary; Heat rate: 25 K/min; Start T: 75 C; End T: 320 C; End time: 2 min; CAS no: 137586; Active phase: Ultra-2; Phase thickness: 0.11 um; Data type: Normal alkane RI; Authors: Hemmersbach, P.; de la Torre, R., Review. Stimulants, narcotics and .beta.-blockers: 25 years of development in analytical techniques for doping control, J. Chromatogr. B, 687, 1996, 221-238.) NIST Spectra nist ri 1881.1 (Program type: Complex; Column… (show more) class: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 15 m; Column type: Capillary; Description: 70 0C (0.7 min) ^ 20 0C/min -; 140 0C ^ 10 0C/min -; 290 0C (9.5 min); CAS no: 137586; Active phase: DB-5; Carrier gas: He; Phase thickness: 0.25 um; Data type: Normal alkane RI; Authors: Rasanen, I.; Ojanpera, I.; Vartiovaara, J.; Vuori, E.; Sunila, P., The advantage of dual-column approach and retention indices combined with refined reporting in gas chromatographic drug screening, J. Hi. Res. Chromatogr., 19, 1996, 313-321.) NIST Spectra nist ri 1871.3 (Program type: Ramp; Column cl… (show more) ass: Semi-standard non-polar; Column diameter: 0.32 mm; Column length: 12.5 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 110 C; End T: 290 C; End time: 6.5 min; Start time: 1 min; CAS no: 137586; Active phase: Ultra-2; Phase thickness: 0.5 um; Data type: Normal alkane RI; Authors: Watts, V.W.; Simonick, T.F., A retention index library for commonly encountered drugs and metabolites using tri-n-alkylamines as reference compounds, nitrogen-phosphorus detectors, and dual capillary chromatography, J. Anal. Toxicol., 11, 1987, 210-214.) NIST Spectra nist ri -
Retention Index (Linear):
1870 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column length: 10 m; Column type: Capillary; CAS no: 137586; Active phase: CP Sil 5 CB; Carrier gas: He; Phase thickness: 5.0 um; Data type: Linear RI; Authors: Aderjan, R.; Bogusz, M., Nitroalkanes as a multidetector retention index scale for drug identification in gas chromatography, J. Chromatogr., 454, 1988, 345-351.) NIST Spectra nist ri 1881 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.53 mm; Column length: 10 m; Column type: Capillary; Description: 100 0C (2 min ) ^ 15 0C/min -; 200 0C ^ 10 0C/min -; 300 0C (8 min hold); CAS no: 137586; Active phase: CP Sil 5 CB; Carrier gas: He; Phase thickness: 5.0 um; Data type: Linear RI; Authors: Aderjan, R.; Bogusz, M., Nitroalkanes as a multidetector retention index scale for drug identification in gas chromatography, J. Chromatogr., 454, 1988, 345-351., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 137586; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri 1884 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.75 mm; Column length: 30 m; Column type: Capillary; Heat rate: 10 K/min; Start T: 160 C; End T: 280 C; End time: 12 min; CAS no: 137586; Active phase: SPB-1; Carrier gas: He; Phase thickness: 1.0 um; Data type: Linear RI; Authors: Christ, D.W.; Noomano, P.; Rosas, M.; Rhone, D., Retention indices by wide-bore capillary gas chromatography with nitrogen-phosphorus detection, J. Anal. Toxicol., 12, 1988, 84-88.) NIST Spectra nist ri 1838 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.53 mm; Column length: 12 m; Column type: Capillary; Heat rate: 6 K/min; Start T: 120 C; End T: 250 C; CAS no: 137586; Active phase: CBP-1; Carrier gas: N2; Data type: Linear RI; Authors: Oyama, N.; Sano, T.; Syoyama, M.; Maeda, K., Studies on systematic analysis of poisonous compounds in forensic chemistry. II. Application of capillary column gas chromatography to substance identification by means of retention indices, Eisei Kagaku, 33(5), 1987, 342-348.) NIST Spectra nist ri 1857 (Program type: Complex; Column… (show more) class: Standard non-polar; Column diameter: 0.22 mm; Column length: 12 m; Column type: Capillary; Description: 120C=;8C/min=;270C=;25C/min=;300C; CAS no: 137586; Active phase: BP-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Stowell, A.; Wilson, L.W., A simple approach to the interlaboratory transfer of drug retention indices determined by temperature programmed capillary gas chromatography, J. Forensic Sci., 32(5), 1987, 1214-1220.) NIST Spectra nist ri 1865 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column length: 1.8 m; Column type: Packed; Heat rate: 8 K/min; Start T: 130 C; End T: 290 C; End time: 8 min; Start time: 2 min; CAS no: 137586; Active phase: SE-30; Carrier gas: N2; Substrate: Chromosorb W; Data type: Linear RI; Authors: Perrigo, B.J.; Peel, H.W., The use of retention indices and temperature-programmed gas chromatography in analytical toxicology, J. Chromatogr. Sci., 19, 1981, 219-226., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 137586; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri 1875 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 137586; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri 1880 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 137586; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri 1882 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 137586; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri 1885 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 137586; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri 1890 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 137586; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri 1892 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 137586; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri 1893 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 137586; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri 1895 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column type: Packed; Heat rate: 7 K/min; Start T: 120 C; End T: 290 C; End time: 10 min; Start time: 4 min; CAS no: 137586; Active phase: Methyl Silicone; Data type: Linear RI; Authors: Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 9, 1985, 49-54.) NIST Spectra nist ri 1854 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 5 min; CAS no: 137586; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Perrigo, B.J.; Ballantyne, D.J.; Peel, H.W., Condierations in developing a data base for drugs on a DBI capillary column, J. Can. Soc. Forensic Sci., 17(2), 1984, 41-49., Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 15 m; Column type: Capillary; Heat rate: 8 K/min; Start T: 120 C; End T: 280 C; End time: 5 min; CAS no: 137586; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Perrigo, B.J.; Peel, H.W.; Ballantyne, D.J., Use of Dual-Column Fused-Silica Capillary Gas Chromatography in Combination with Detector Response Factors for Analytical Toxicology., J. Chromatogr., 341, 1985, 81-88.) NIST Spectra nist ri 1852 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.2 mm; Column length: 12 m; Column type: Capillary; Heat rate: 20 K/min; Start T: 50 C; End T: 300 C; End time: 3 min; Start time: 1 min; CAS no: 137586; Active phase: Methyl Silicone; Carrier gas: He; Phase thickness: 0.33 um; Data type: Linear RI; Authors: Newton, B.; Foery, R.F., Retention indices and dual capillary gas chromatography for rapid identification of sedative hypnotic drugs in emergency toxicology, J. Anal. Toxicol., 8, 1984, 129-134.) NIST Spectra nist ri 1848 (Program type: Ramp; Column cl… (show more) ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 15 m; Column type: Capillary; Heat rate: 5 K/min; Start T: 120 C; End T: 280 C; End time: 5 min; CAS no: 137586; Active phase: DB-1; Carrier gas: He; Phase thickness: 0.25 um; Data type: Linear RI; Authors: Perrigo, B.J.; Ballantyne, D.J.; Peel, H.W., Condierations in developing a data base for drugs on a DBI capillary column, J. Can. Soc. Forensic Sci., 17(2), 1984, 41-49.) NIST Spectra Haven't found what you were looking for?
Search for samples, answers to your questions and flashcards